ECB violations
Carpenter Avenue, Bronx • Block 04656 • Lot 0001
42 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 13, 2026 | 39554054N | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION OF A 6-STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE, DURING MY INSPECTION I NOTICED SI... | $1,250 | $1,250 | Jan 22, 2027 |
| Feb 10, 2026 | 39176672P | RESOLVE | CLASS - 3 | FEDERAL STEAM BOILER HAS POOR FLAME FROM OIL BURNERÝSMOKING¨+101 FEEDER IS LEAKING WATER+HEAT TIMER NEEDS SERVICE TEC... | $0 | $0 | Sep 4, 2026 |
| Oct 3, 2025 | 35717660L | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALL FACADE AND APPURTENANCES.ATTIME OF INSPECTION OBSERVED IN EX.1 NORTH WINDO... | $7,500 | $7,500 | Dec 19, 2025 |
| Jan 28, 2025 | 35689260R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE AT TIME OF INSPECTION OBSERVED OBJECTS ON FIRE ESCAPE MAY CAUSE... | $1,250 | $1,250 | Apr 4, 2025 |
| Jan 28, 2025 | 35689259J | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE AT TIME OF INSPECTION OBSERVED BROKEN/CRACKED GL... | $6,250 | $6,250 | Sep 26, 2025 |
| Nov 19, 2024 | 35689178H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.-AT TIME OF INSPECTION, OBSERVED AN AIR CONDITIONER UNIT ON THE FIRE ... | $1,250 | $1,250 | Jul 22, 2025 |
| Nov 19, 2024 | 35686799R | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDINGS EXTERIOR WALLS AND/OR APPURTENANCES.AT TIME OF INSPECTION OBSERVED BULGING MASONRY AT M... | $2,500 | $2,500 | Jul 22, 2025 |
| Oct 30, 2024 | 39128890R | RESOLVE | CLASS - 1 | : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON IN... | $3,125 | $3,125 | Jan 3, 2025 |
| Oct 16, 2024 | 39127532M | RESOLVE | CLASS - 1 | RESPONDING, TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, DEVICE IS FOUND TO BE OUT OF SERVICE, A RECURRING CLASS 1 V... | $3,125 | $3,125 | Dec 20, 2024 |
| Aug 19, 2024 | 35686231Y | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AS NOTED:-AT TIME OF INSPECTION, I OBSERVED ON EXPOSUR... | $2,500 | $2,500 | Nov 15, 2024 |
| Jun 24, 2024 | 39117539X | RESOLVE | CLASS - 1 | CEASE USE ITEMS: 1)INOPERATIVE ZONE LOCK RESTRICTOR. 2) CAR DOORS CAN BE PULLED APART. 3) MINIMAL CAR DOOR PROTECTION... | $1,250 | $1,250 | Aug 30, 2024 |
| Apr 30, 2024 | 39113065P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. PIT DIRTY, CLEAN. IN CAR ALARM INOPERATIVE, REPAIR. CAR DOOR G... | $0 | $0 | Jul 5, 2024 |
| Dec 27, 2023 | 39102264Y | RESOLVE | CLASS - 2 | FOUND FEDERAL FST-80 BOILER WITH OIL PUMP SET RUNNING CONSTANT, TO RUN ONLY WHEN BURNER RUNS, SAFETY RELIEF VALVE MIS... | $0 | $0 | Mar 1, 2024 |
| Jan 13, 2023 | 39077747R | RESOLVE | CLASS - 1 | ELEVATOR OUT OF SERICVE TIME OF COMPLAINT 2358739. COMPLAINT SATATES THAT THE ELEVATOR WAS OUT OF SERIVCE. REMEDY REP... | $1,250 | $1,250 | Mar 31, 2023 |
| Dec 16, 2022 | 38274605H | RESOLVE | CLASS - 1 | CEASE USE; 01X10, 05X10: 01-X-10 REPAIR INOPERATIVE STOP SWITCH IN CAR05-X-10 REPAIR INOPERATIVE CAR DOOR RESTRICTOR | $1,250 | $1,250 | Mar 3, 2023 |
| Jun 1, 2022 | 39063324H | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED, / UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE , AS PER 1 RCNY 11-02. REMEDY, ... | $3,125 | $3,125 | Dec 17, 2026 |
| Sep 22, 2021 | 39048007Z | RESOLVE | CLASS - 1 | THE COMMISSIONER ORDERS THAT YOU TIMELY CORRECT THESE CONDITIONS AND FILE A CERTIFICATE OF SUCH CORRECTION. SEE 1RCNY... | $1,563 | $1,563 | Jan 7, 2022 |
| Oct 30, 2020 | 39031318P | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ITEM, A) NO DOOR MONITORING INSTALLED, AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC, REM... | $1,250 | $0 | Jan 29, 2021 |
| Feb 8, 2018 | 38261211M | RESOLVE | CLASS - 1 | C/U 05A10,60M03,70P07.05A10 CAR DOOR ZONE RESTRICTOR ALTERED RENDERED IT.INOPERATIVE REPAIR & CONTACT NYCDOB TO RETUR... | $1,000 | $0 | Mar 30, 2018 |
| Apr 11, 2017 | 38254356H | RESOLVE | CLASS - 1 | 97X10 FAILURE TO MAINTAIN BUILDIN GIN CODE COMPLIANT MANNER,ELEVATOR AS PER BC3001.2&27-087 .ONLY ELEVATOR IN BUILDIN... | $10,000 | $0 | Jun 2, 2017 |
| Apr 3, 2017 | 38254027R | RESOLVE | CLASS - 1 | 97X17 THE ONLY ELEVATOR IN 6 STORY BLDG OUT OF SERVICE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREA... | $0 | $0 | May 19, 2017 |
| Aug 25, 2016 | 38245062H | RESOLVE | CLASS - 1 | CEASE USE. 8V1,16I10,5J1. (8V)FLR STOPS EXCESSIBLY OUT OF LEVEL MUST ADJUST IMMEDIATELY. (16I)DAMAGE BSMT DOOR HOISTW... | $5,000 | $0 | Mar 31, 2017 |
| Jun 3, 2016 | 38243501L | RESOLVE | CLASS - 2 | 02M07, 08J10, 40P16, 70P16. | $0 | $0 | Jul 29, 2016 |
| Jul 15, 2011 | 34912121J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.MISSING TERRACOTTO COPING STONE @ FRONT & SIDE OF BLDG PARAPET WALL.S... | $0 | $0 | Oct 28, 2011 |
| Apr 26, 2010 | 38209544M | RESOLVE | CLASS - 2 | 40P7/ 11N10/ 16L10/ 5K11/ 77K10/ 70O2/ 11- BY PASS 2-3-5 | $2,500 | $0 | Jul 9, 2010 |
| Jan 20, 2010 | 38208587H | RESOLVE | CLASS - 2 | 98BB5/ 60X11/ 61T15/ 68M7/ 69M7/ 58H11/ 11N10/ 9H10/ 16B1/ 21B10/ 10M7/ 70O2/ 77K11/ 11- BY PASS 2ND & 3RD FL 21 5TH FL | $500 | $0 | May 7, 2010 |
| Mar 10, 2009 | 32065017M | RESOLVE | CLASS - 2 | 16,32A,38,48A,50,50A,50B,50C. 50- CHECK VALVE MISSING ON FEED LINE. 50A- PULLEY GUARD MISSING ON TRANSFER PUMP. 50B- ... | $0 | $0 | May 1, 2009 |
| Dec 11, 2008 | 38198735Y | RESOLVE | CLASS - 2 | 98BB599BB556Y1335Q341D6. | $0 | $0 | Jan 30, 2009 |
| Jul 23, 2008 | 38189700J | RESOLVE | CLASS - 3 | 39Q03 40P16 52M07 70P16 100X10, 39Q03 INSTALL GUARD FOR LIGHT ON TOP OF CAR 40P16 PROVIDE ACCESS TO MOTOR RM SO THAT ... | $100 | $0 | Sep 19, 2008 |
| May 13, 2008 | 38184701Z | RESOLVE | Hazardous | 11D06.23D06.66O02. 11D06 PROPERLY SECURE CAR STATION 23D06 PROPERLY SECURE LOBBY HALL BUTTON | $0 | $0 | Jul 18, 2008 |
| Dec 12, 2006 | 38162157R | RESOLVE | Non-Hazardous | 84I10,11X10,39O02,40W07,11D06,05J01,41G07. (84-I-10)REPAIR DAMAGED CABOR REPLACE. ROTTED OUT (11-X-10)REPAIR CAR STAT... | $2,500 | $0 | Jan 26, 2007 |
| Jun 24, 2003 | 38139072M | RESOLVE | Non-Hazardous | 10M07 10H12 66O02 06B01 38Y02 26U07 40T07 40B11 58Y02 10-GIBS WORK AND MISSING ON SLOW SPEED DOOR, 06 CAR STOPS IN FL... | $2,500 | $0 | Sep 19, 2003 |
| Oct 23, 2001 | 34289850H | ACTIVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECTS ARE: STUCCO AND BRICK WORK AT PARAPET WALL. HAS CRACKED AND SEPAR... | $800 | $0 | Nov 2, 2001 |
| Nov 1, 2000 | 38109332M | RESOLVE | Non-Hazardous | 9K12,11Q3,15#11,17I11,20#11,28H12,57O02,74I12.9-POSTED DOOR GIBBS.11-UNGUARDED CAR LIGHTS HOES.57-PIT DIRTY.24-CAR DA... | $350 | $0 | Jul 12, 2001 |
| Apr 3, 2000 | 38095852L | RESOLVE | Non-Hazardous | 36I12,15I11,15I11. 36- MOTOR ROOM DOOR BADLY DAMAGED, NEEDS TO BE REPLACED. 15- LOBBY FLOOR SLAMMING HARD. FOURTH FLO... | $350 | $0 | Jul 12, 2001 |
| May 28, 1999 | 38087603K | RESOLVE | Non-Hazardous | 57O,75U,18Q,3O,3Q,31Q,50Y,50F,33L,40L. PROVIDE COVER AND SECOND FLOOR LOCKS, CLEAN CAR TOP AND PROVIDE COVER 2X2 BOX,... | $350 | $0 | Feb 11, 2000 |
| Jul 29, 1998 | 38077434J | RESOLVE | Non-Hazardous | 13M12,18Q3,35P17,57O02,62M12,. 62- TOE GUARD. 13- REPLACE CAR MIRROR 18-INSTALL GUARDS INTERLOCKS. | $350 | $0 | Feb 11, 2000 |
| Nov 15, 1997 | 38066067N | RESOLVE | Non-Hazardous | 08V01,13112,50Y1,39H08,75U02,51002,11M02,74AD06 74BD06 28B01,74D02 | $350 | $0 | Feb 11, 2000 |
| Nov 13, 1995 | 38052552J | RESOLVE | Non-Hazardous | 73X,35O,57O,74O,. 73-RESTORE ELEV. TO SERVICE 74-CLEAN TOP OF CAR. | $200 | $0 | Feb 11, 2000 |
| Jul 7, 1994 | 38043041N | RESOLVE | Non-Hazardous | 13L,18M,22D,74M,74I,(18)REPLACE MISSING INTERLOCK CONVERS WHERE NECESSARY(74)REPLACE MISSING SPICE BOX CONVERS WHERE ... | $0 | $0 | Oct 24, 1994 |
| Sep 7, 1993 | 34085576J | ACTIVE | Non-Hazardous | PLUMBING WORK WITHOUT A PERMIT. GAS PIPE FROM METER IN BSMT TO RGE IN APT. 6A WAS THROUGH AN ABANDONED DUMBWAITER SHA... | $1,000 | $0 | Oct 22, 1993 |
| May 11, 1993 | 38033212J | RESOLVE | Non-Hazardous | 03M,14M,11Q,08B,10I,20I,57O. 03 CAPACITY PLATE. 10 NO REPONSE TO 6TH FLOOR CALL. 20 NO RESPONSE TO 6TH FLOOR CAL. | $1,000 | $0 | Oct 22, 1993 |