Maintenance code violations
3825-3827 Bronxwood Avenue, Bronx • Block 04679 • Lot 0001
206 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Oct 15, 2012 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, ... | — | Oct 21, 2012 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND W... | 17 | Nov 8, 2012 |
| Oct 4, 2012 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... | 17 | Jan 7, 2013 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 17, 4th ST... | 17 | Nov 8, 2012 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND W... | 17 | Nov 8, 2012 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND W... | 17 | Nov 8, 2012 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCA... | 17 | Nov 8, 2012 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, WEST... | 17 | Nov 8, 2012 |
| Oct 4, 2012 | B | VIOLATION DISMISSED | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SHOWER ROD IN THE BATHROOM LOCATED AT APT 17, 4th STORY, 2nd APART... | 17 | Nov 8, 2012 |
| Oct 3, 2012 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 8 | Nov 12, 2012 |
| Oct 3, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, ... | 8 | Nov 7, 2012 |
| Oct 3, 2012 | A | VIOLATION CLOSED | SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st RO... | 8 | Jan 6, 2013 |
| Oct 3, 2012 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURF... | 8 | Jan 6, 2013 |
| Oct 3, 2012 | B | VIOLATION CLOSED | SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ... IN THE 1st ROOM FROM... | 8 | Nov 7, 2012 |
| Oct 3, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE 1st WINDO... | 8 | Nov 7, 2012 |
| Oct 3, 2012 | C | VIOLATION CLOSED | SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPEC... | 8 | Oct 24, 2012 |
| Oct 3, 2012 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR IMPROPERLY INSTALLED AWAY FROM SLEEPING AREA IN THE ENT... | 8 | Nov 7, 2012 |
| Oct 3, 2012 | B | VIOLATION CLOSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). IMPROPERLY INSTALLED AWAY FROM SLEE... | 8 | Nov 7, 2012 |
| Oct 3, 2012 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME F... | 8 | Jan 6, 2013 |
| Sep 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... | 5 | Oct 18, 2012 |
| Sep 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING I... | 5 | Oct 18, 2012 |
| Sep 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING I... | 5 | Oct 18, 2012 |
| Aug 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR TO ROOM IN THE 1st ROOM FROM NORTH LOC... | 9 | Sep 17, 2012 |
| Aug 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... | 9 | Sep 17, 2012 |
| Aug 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 9, 3rd STORY... | 9 | Sep 17, 2012 |
| Aug 13, 2012 | B | VIOLATION CLOSED | SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCAT... | 9 | Sep 17, 2012 |
| Jul 10, 2012 | C | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE KEY OPERATED LOCK AT DOOR IN THE ENTRANCE LOCATED ... | 1 | Jul 16, 2012 |
| Jul 10, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 1st ROOM FROM NORTH LO... | 1 | Aug 14, 2012 |
| Jun 1, 2012 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, 1st DOOR ... | 8 | Sep 4, 2012 |
| Apr 20, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN ... | 7 | May 25, 2012 |
| Apr 6, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND... | 7 | May 11, 2012 |
| Apr 6, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE BATHRO... | 7 | May 11, 2012 |
| Apr 6, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AROUND BATH... | 7 | May 11, 2012 |
| Apr 6, 2012 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WALL CABINETS IN THE KITCHEN LOCATED AT APT 7, 2nd ... | 7 | May 11, 2012 |
| Aug 10, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL CEILINGS ... | 5 | Sep 14, 2011 |
| Jun 24, 2011 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE FOY... | 22 | Sep 27, 2011 |
| May 19, 2011 | C | VIOLATION CLOSED | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND TH... | 8 | Jun 28, 2011 |
| May 19, 2011 | C | VIOLATION CLOSED | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND TH... | 8 | Jun 28, 2011 |
| May 19, 2011 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, 2nd WINDO... | 8 | Aug 22, 2011 |
| Apr 12, 2011 | C | VIOLATION DISMISSED | SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERI... | 22 | May 8, 2011 |
| Apr 12, 2011 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 22 | May 8, 2011 |
| Apr 11, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKFACE AND MORTAR JOINTS AT... | — | May 16, 2011 |
| Apr 4, 2011 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED PLAST... | 22 | Apr 10, 2011 |
| Apr 4, 2011 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN CLOSET 1st CLOSET FROM SOUTH AT WEST ... | 22 | Apr 10, 2011 |
| Feb 11, 2011 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING I... | 8 | Mar 18, 2011 |
| Feb 11, 2011 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FRO... | 8 | May 17, 2011 |
| Feb 11, 2011 | B | NOT COMPLIED WITH | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8, 3rd STORY, 1st... | 8 | Mar 18, 2011 |
| Dec 10, 2010 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURF... | 22 | Mar 15, 2011 |
| Oct 14, 2010 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE AT PUBLIC H... | — | Nov 18, 2010 |
| Apr 13, 2010 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS IN ... | 20 | Jul 17, 2010 |