ECB violations
3362-3364 Boston Road, Bronx • Block 04733 • Lot 0006
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 17, 2022 | 39507689P | RESOLVE | CLASS - 2 | NOTE: OBSERVED FULLY FENCED 7STY NB UNDER CONSTRUCTION AT ROOF LEVEL, ACTIVE JOB SITE. ALSO OBSERVED IN DOB SYSTEM TE... | $0 | $0 | Dec 2, 2022 |
| Oct 17, 2022 | 39507687L | RESOLVE | CLASS - 1 | NOTE: OBSERVED A 7STY NB UNDER CONSTRUCTION AT ROOF LEVEL, ACTIVE JOB SITE. ALSO OBSERVED AN UNFINISHED STAIR OPENING... | $2,500 | $0 | Dec 2, 2022 |
| Oct 17, 2022 | 39507686J | RESOLVE | CLASS - 1 | NOTE: AT THE TIME OF INSPECTION OBSERVED 7STY BLDG. UNDER CONSTRUCTION AT ROOF LEVEL, ACTIVE JOBSITE. OBSERVED PILES ... | $625 | $0 | Dec 2, 2022 |
| May 19, 2022 | 35647161X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SEC REQUIREMENTS:NOTED:ATO MY INSP OBSERVED CONST DEBRIS@EXP1 CONSISTS ... | $1,250 | $0 | Nov 7, 2022 |
| May 24, 2021 | 35511585R | RESOLVE | CLASS - 2 | TEMP CONST EQUIPMENT FENCE.NOTE:ATOI ON 7STYNB I OBSERVED NO ONGOING CONST WORK.ALSO OBSERVED FENCE HAS BEEN ERECTED ... | $0 | $0 | Feb 11, 2022 |
| May 7, 2021 | 35559651Z | RESOLVE | CLASS - 1 | BC1704.1.2 UPON CONCRETE ENFORCEMENT UNIT(CEU)REVIEW OF TR-1 SPECIAL INSPECTION REPORT FOR CONCRETE CAST-IN-PLACE SUB... | $6,250 | -$6,250 | Jun 17, 2022 |
| Apr 1, 2021 | 35537623Y | RESOLVE | CLASS - 1 | BC16&BC107=INADEQUATE DESIGN DOCUMENTS.DRAWINGS PER CONCRETE ENLARGMENT UNIT (CEU) AUDIT ON STRUCTURAL DRAWINGS SUBMI... | $2,500 | $0 | Jan 28, 2022 |
| Mar 22, 2021 | 35537622M | RESOLVE | CLASS - 1 | BC 1704.1.3 RESPONDENT FAILED TO COMPLY TO BC 1704.1.3.1 RESPONSIBILITY OF THE PERMIT HOLDER STATEMENT OF SPECIAL INS... | $2,500 | $0 | Jun 18, 2021 |
| Feb 18, 2021 | 35552626P | RESOLVE | CLASS - 1 | 3314.5.5 PLATFORM NOT TIEDOWN. COMPETENT PERSON PRESENT AT SITE. ONGOING CONSTRUCTION WORK UNDER APP#210178680 HAS SU... | $2,500 | $0 | May 7, 2021 |
| Feb 18, 2021 | 35552628Z | RESOLVE | CLASS - 2 | NO PEDESTRIAN PROTECTION@TIME OF INSP@ACTIVE CONST SITE,I OBSERVED SWS@EXP1 IN UNSAFE CONDITION NOTED-MISSING PARAPET... | $2,400 | $0 | May 7, 2021 |
| Feb 18, 2021 | 35552627R | RESOLVE | CLASS - 1 | 3314.8.2 LOOSE DEBRIS NETTING NOTED:@TIME OF INSP,I OBSERVED ACTIVE SITE W/SUPPORTED SCAFFOLD@ALL EXPS W/LOOSE NETING... | $2,500 | $0 | May 7, 2021 |
| Feb 18, 2021 | 35552629K | RESOLVE | CLASS - 1 | GUARDRAIL SYSTEM INADEQUATE @TIME OF INSP OF ACTIVE SITE,I OBSERVED GUARDRAIL SYSTEM@ROOF LEVEL MISSING MIDRAIL.NOTED... | $2,500 | $0 | May 7, 2021 |
| Jan 12, 2021 | 39034759Y | RESOLVE | CLASS - 2 | THE INSTALLED METAL FRAMED WALLS ON EXP. 2 AND EXP. 4 FROM FIRST TO SECOND FLOOR, THERE WERE NO OUTBOARD CONTINUOUS I... | $2,000 | $0 | Apr 2, 2021 |
| Nov 24, 2020 | 35542428P | RESOLVE | CLASS - 1 | BC 3301.7 FAILURE TO PROVIDE APPROVED P.E DESIGN DRAWING AND EOR. AS NOTED:AT TIME OF INSPECTION FOR AN ACTIVE CONSTR... | $1,250 | $0 | Mar 5, 2021 |
| Nov 24, 2020 | 35542429R | RESOLVE | CLASS - 1 | BC 3301.4 FAILURE TO PROVIDE SAFETY STRAP INSTALLATION INSPECTION LOG.AS NOTED:AT TIME OF INSPECTION FOR AN ACTIVE CO... | $2,500 | $0 | Mar 5, 2021 |
| Aug 7, 2020 | 35469313R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE DOCUMENTS TO BE KEPT ONSITE AT TIME OF INSPECITON OF AN ACTIVE 7 STORY NEW BUILDING.I OBSERVED CON... | $2,500 | $2,500 | Mar 12, 2021 |
| Aug 7, 2020 | 35469312P | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.AT TIME OF INSPECTION OF AN ACTIVE 7 STORY NEW BUILDING.I OB... | $5,000 | $5,000 | Mar 12, 2021 |
| May 26, 2020 | 35492411X | RESOLVE | CLASS - 1 | CORRECTING UNSAFE CONDITIONS. AT TIME OF INSPECTION ON A ACTIVE JOBSITE 5TH FL IT WAS OBSERVED THAT CONSTRUCTION SUPE... | $10,000 | $0 | Oct 16, 2020 |
| May 26, 2020 | 35492405J | RESOLVE | CLASS - 1 | SEC. 3309.10 PROTECTION ROOFS. AT TIME OF INSPECTION ON A ACTIVE JOBSITE FORMING 5TH FLOOR,IT WAS OBSERVED THAT ROOF ... | $2,500 | $2,500 | Jul 31, 2020 |
| May 26, 2020 | 35492406L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE & MAINTAIN HOUSEKEEPING. AT TIME OF INSPECTION ON AACTIVE JOBSITE FORMING 5TH FL,IT WAS OBSERVED I... | $2,500 | $2,500 | Jul 31, 2020 |
| May 26, 2020 | 35492407N | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED PLANS-SSP. AT TIME OF INSPECTION ON A ACTIVE JOBSITE FORMING 5TH FL. IT WAS OBSERVE... | $2,500 | $2,500 | Jul 31, 2020 |
| May 26, 2020 | 35492408P | RESOLVE | CLASS - 1 | SEC. 3301.1.2 FAILURE TO COMPLY W/FDNY(GENERAL). AT TIME OF INSPECTIONON A ACTIVE JOBSITE FORMING 5TH FL,IT WAS OBSER... | $2,500 | $2,500 | Jul 31, 2020 |
| May 26, 2020 | 35492409R | RESOLVE | CLASS - 1 | DOCUMENTS TO BE KEPT ON SITE. AT TIME OF INSPECTION ON A ACTIVE JOBSITE FORMING 5TH FL,APPROX 50 FEET IN HEIGHT,IT WA... | $1,250 | $1,250 | Jul 31, 2020 |
| May 26, 2020 | 35492410Y | RESOLVE | CLASS - 1 | SEC. 2113.1.6.1 RESPONSABILY OF OWNER OF TALLER BLDG-CHIMNEY. AT TIME OF INSPECTION ON A ACTIVE JOBSITE FORMING 5TH F... | $2,500 | $2,500 | Jul 31, 2020 |
| Mar 5, 2020 | 35471284J | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.AT MY TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION SITE GRO... | $2,500 | $2,500 | Oct 9, 2020 |
| Mar 5, 2020 | 35471283H | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMEDMENTS"SITE SAFETY PLANS"AT TIME OF INSPE... | $625 | $625 | Oct 9, 2020 |
| Mar 5, 2020 | 35471286N | RESOLVE | CLASS - 2 | BC3307.2.1 FAILURE TO COMPLY WITH D.O.T REGULATION AS PER 34RCNY.2-05 AND ADMIN CODE PROVISIONS 19-107,19-108 OR 19-1... | $625 | $625 | Oct 9, 2020 |
| Mar 5, 2020 | 35471285L | RESOLVE | CLASS - 1 | NO HANDRAILS.AT TIME OF INSPECTION I OBSERVED AN ACTIVE CONSTRUCTION SITE WITH POUR CONCRATE ON PROGRESS,DURING INSPE... | $2,500 | $2,500 | Oct 9, 2020 |