ECB violations
658-674 East 233 Street, Bronx • Block 04835 • Lot 0070
54 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 9, 2025 | 39163242M | RESOLVE | CLASS - 2 | WORK WITHOUT PERMIT. NOTED: ILLUMINATED SIGN APPROX: 20'X3' INSTALLED WITHOUT PERMIT., OBTAIN ALL PERMITS | $1,250 | $0 | Dec 19, 2025 |
| Aug 6, 2025 | 39156232N | RESOLVE | CLASS - 1 | AGG 2 VIOLATION ISSUED, UPON INSPECTION OF DEVICE, NO DLM WAS FOUND ON CONTROLLER, CAR DOOR RESTRICTOR NOT WORKING, A... | $6,250 | $6,250 | Sep 25, 2026 |
| Feb 6, 2025 | 39137685M | RESOLVE | CLASS - 3 | ACCESS TO THE HEATING SYSTEM SHALL BE READILY PROVIDED TO THE DEPT. ASPER HMC 27-203 SUBMIT A CERTIFICATE OF CORRECTI... | $500 | $0 | Jul 18, 2025 |
| Dec 30, 2024 | 39134047Y | ACTIVE | CLASS - 1 | CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO... | $1,250 | $0 | Mar 7, 2025 |
| Jun 24, 2024 | 39117520X | ACTIVE | CLASS - 1 | CEASE USE ITEM: ZERO CLEARANCE BETWEEN SADDLE AND SILL. SADDLE HITTING SHAFT WALL BETWEEN BASEMENT AND 1ST FLOOR. CLA... | $1,250 | $0 | Aug 30, 2024 |
| May 21, 2024 | 38274951K | ACTIVE | CLASS - 1 | 05-A-10, 69-M-67, 100-N-10, 1-D-06, 67-X-10, 42-M-07. RESPONDING TO A 311 ELEVATOR COMPLAINT, VIOLATION WAS ISSUED, L... | $3,125 | $0 | Aug 2, 2024 |
| Mar 8, 2024 | 39108119P | ACTIVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT,UPON INSPECTION ON THE ONLY DEVICE IN BUILDING, CEASE USE AND CLASS 1 VIOLATIO... | $3,125 | $0 | May 17, 2024 |
| Nov 6, 2023 | 39098890M | RESOLVE | CLASS - 1 | RESPONDING ON A SCHEDULED RESTORE TO SERVICE RE-INSPECTION, NO ONE WAS PRESENT DEVICE WAS NOT LIFTED DEVICE REMAIN CE... | $3,125 | $0 | May 24, 2024 |
| Oct 26, 2023 | 39098137M | ACTIVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT. UPON INSPECTION OF DEVICE, CEASE USE VIOLATION ISSUED FOR, MISSING CAR DOOR R... | $3,125 | $0 | Jan 5, 2024 |
| Sep 8, 2023 | 38274868J | ACTIVE | CLASS - 1 | 42-M-5AGGII,97-X-17,42-N-11,2-X-10. AGGRAVATED II CONDITION. RESPONDENT HAS IGNORED NUMEROUS COMMISSIONERS ORDERS TO ... | $6,250 | $0 | Nov 17, 2023 |
| Aug 22, 2023 | 39093083N | ACTIVE | CLASS - 2 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPA... | $1,250 | $0 | Dec 1, 2023 |
| Aug 22, 2023 | 39093086Z | ACTIVE | CLASS - 2 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPA... | $1,250 | $0 | Dec 1, 2023 |
| Aug 10, 2023 | 39092298X | ACTIVE | CLASS - 2 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPA... | $1,250 | $0 | Nov 3, 2023 |
| Jun 23, 2023 | 38274847K | ACTIVE | CLASS - 1 | 42M7 AND 2X10 NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 APPENDIX K3 OF THE NYC BC.T... | $3,125 | $0 | Sep 1, 2023 |
| Mar 30, 2023 | 39082687K | ACTIVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION OF DEVICE VIOLATION WAS FOUND ITEMS ARE, 1/ NO DOOR LOCK MONI... | $3,125 | $0 | Jun 16, 2023 |
| Sep 21, 2022 | 39070517J | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED NO DLM INSTALLED IN THIS CONTROLLER. NO DOOR LOCK MONITORING IN THIS CONTROLLER AS MANDATED ... | $3,125 | $0 | Dec 16, 2022 |
| Jul 26, 2022 | 39066977Z | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 O... | $3,125 | $0 | Sep 16, 2022 |
| May 12, 2020 | 38273400J | RESOLVE | CLASS - 2 | 42-L-10,59-BB-5=42-CAR BY PASSES FLOOR CALLS SOMETIMES:REMEDY REPAIR SELECTOR OR ADJUST/59-BB-5-BRAKE MAINTENCED TAG ... | $625 | $0 | Oct 2, 2020 |
| Aug 8, 2018 | 35387550L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35336381J ISSUED ON 06-30-18 & TO FILE A C OF C PURSUAN... | $1,250 | $0 | Nov 9, 2018 |
| Aug 7, 2018 | 38252917J | RESOLVE | CLASS - 2 | 02X10,39O02,40Q03,42D06,56Y13,98M05. 02X10-REPAIR OUTSIDE COMMUNICATION (TELEPHONE; 39O02-CLEAN CAR TOP; 40Q03-INSTAL... | $0 | $0 | Sep 21, 2018 |
| Jul 17, 2018 | 38264074Z | RESOLVE | CLASS - 2 | 64M07,39X10,39O02,31V01,56Y10,60M03,68B07,35M07,10B07,78H14,70O02,67X10-64M07)REMEDY: PROVIDE AND INSTALL NYC DEVICE ... | $0 | $0 | Aug 31, 2018 |
| Jun 30, 2018 | 35336381J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT REAR OF BUILDING EXP #3 OBSERVED THE RETAINING WALL ... | $3,125 | $0 | Nov 16, 2018 |
| May 9, 2018 | 35337554N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35322349M ISSUED 03/19/18 AND TO FILE... | $1,250 | $0 | Oct 12, 2018 |
| Apr 19, 2018 | 38262617R | RESOLVE | CLASS - 1 | CU-05A10; 39O02,70O02,80M07,71X10,03D06,67X10,41M07,44M03,41O02,68B01,60X10. 05A10-DOOR RESTRICTOR TAMPERED WITH REND... | $1,250 | $0 | Jun 15, 2018 |
| Apr 4, 2018 | 32093097J | RESOLVE | CLASS - 2 | 15,32A-15)OPENING IN WALLS/CEILING. 32)WIRING EXPOSED. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT CERTIFICATION OF C... | $0 | -$10 | Jun 1, 2018 |
| Mar 19, 2018 | 35322349M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: REAR OF BUILDING EXP 3 RETAINING WALL IS DETERIORATING ... | $1,250 | $0 | Aug 24, 2018 |
| Mar 19, 2018 | 35324838M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 3/19/2018 AT ABOVE GARBAGE IS STORED ON TOP AND AL... | $0 | $0 | May 18, 2018 |
| Nov 15, 2017 | 35297036J | RESOLVE | CLASS - 1 | SEC. 430.75 NO MOROE DISCONNECT PROVIDED. OBSERVED ON ROOF AREA KITCHEN EXHAUST FAN WIRING FROM RESTAURANTS CONNECTED... | $1,600 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35293861L | RESOLVE | CLASS - 2 | FAILUR ETO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORRI... | $500 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35297033Y | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE GROUND FAULT CIRCUIT INTERRUPTOR(GFCI)PROTECTION AS REQUIRED. OBSERVED IN BASEMENT BOILER RM & BAS... | $2,400 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35297035H | RESOLVE | CLASS - 2 | SEC. 250.68 WATER MAIN GROUND CLAMP NOT ACCESSIBLE. OBSERVED IN BASEMENT AREA OF PHARMACY,CONDUIT LEADING TO WATER MA... | $400 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35293862N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTE:LAUNDRY/ON THE GROUND LEVEL HAS NO LINT TRAP ON THERE MAIN EXH... | $250 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35297178P | RESOLVE | CLASS - 2 | FGC 401.1 GAS PIPING NOT LABELED OBSERVED ON 11//15/2017 @ABOVE ADDRESS GAS PIPING IN THE ROOM ADJACENT FROM THE BOIL... | $800 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35297032M | RESOLVE | CLASS - 1 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIAL APPARATUS,DEVICE,APPLIANCE OR WIRING IN USE. OBSERVED IN B... | $1,600 | $0 | Mar 9, 2018 |
| Nov 15, 2017 | 35297034X | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ADEQUATE GROUNDING TO ELECTRICAL SYSTEMS. OBSERVED SERVICE SWITCH(400AMP)IN BASEMENT W/O GROUNDING... | $2,400 | $0 | Mar 9, 2018 |
| May 9, 2017 | 35260830H | RESOLVE | CLASS - 1 | B180,1,FGC401.1. GAS PIPING NOT LABELED.OBSERVED ON 5/9/17 GAS PIPING IN BSMT NOT LABELED. PHOTOS TAKEN. REMEDY: COMP... | $800 | $0 | Oct 6, 2017 |
| May 9, 2017 | 35252994Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORR... | $500 | $0 | Oct 6, 2017 |
| May 9, 2017 | 35260831J | RESOLVE | CLASS - 1 | B180,1,FGC408.2.DRIP-FUTURE CONNECTIONS EXIST DOWN STRAM OF APPLIANCES.OBSERVED ON 05/09/2017 @ ABOVE ADDRESS. FUTURE... | $800 | $0 | Oct 6, 2017 |
| Jan 25, 2017 | 38252082K | RESOLVE | CLASS - 2 | 59T15,68B7,40T15,2B7,8V1,39O2,70O2. 40-UNLABELED MOTOR ROOM DOOR; 2-NO OUTSIDE COMM; 59-LABEL BRAKE FOR BRAKE MAINT; ... | $500 | $0 | Jun 9, 2017 |
| Nov 23, 2016 | 35221900M | RESOLVE | CLASS - 1 | SEC. 408.2 MISC VIOLATION DRIPS-FUTURE CONNECTS EXIT DOWN STREAM OF APPLIANCE OBSERVED ON 11-23-16 IN BASEMENT OF ABO... | $800 | $0 | Jun 23, 2017 |
| Oct 17, 2016 | 35203608X | RESOLVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. AT THE TIME 2PMOF MY INSPECTION,ON 10-17-16 AT THE ABOVE ADDRE... | $1,000 | $0 | Apr 7, 2017 |
| Oct 17, 2016 | 35203607Y | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. AT THE TIME 2PM OF MY INSPECTION ON 10-17-16 AT THEABOVE ADDRESS,I OBSERVED NEWLY INSTALLED GAS PI... | $1,600 | $0 | Apr 7, 2017 |
| May 27, 2016 | 35177898R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.ILLUMINATION FOR EXITS.EXIT DISCHARGES & PUBLIC CORRIDORS PER BC100... | $500 | $0 | Jan 20, 2017 |
| Jun 12, 2015 | 38236303P | RESOLVE | CLASS - 2 | 8V1,3I10,42G11,68U7. 3-PHONE NOT WORKING. | $250 | $0 | Sep 11, 2015 |
| Apr 17, 2012 | 34964481H | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOV #34936733R ISSUED ON 2.22.12. REMEDY: COMPLY W/THE COMM... | $0 | $0 | Jun 1, 2012 |
| Sep 14, 2011 | 34927482R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLAINT MANNER. NOTED: AT NORTH ELEVATION (FRONT OF PREMISES) ROLL DOWN GATE... | $2,500 | $0 | Nov 4, 2011 |
| Sep 30, 2008 | 38191914H | RESOLVE | CLASS - 2 | 35Q03.36D06.39O02.42D06.60Q03.70O02.77Q03.98BB05.35Q03 INSTALL COVERS FOR ELECTRICAL BOXES IN SHAFTWAY 36D06 SECURE P... | $0 | $0 | Feb 20, 2009 |
| Oct 13, 2007 | 34589726P | RESOLVE | Hazardous | SEC. ZR 23-44. NOT A PERMITTED OBSTRUCTION IN SIDE YARD AC UNIT INSTALLED IN SIDE YARD FOR USE AT COMMERCIAL LAUNDROM... | $240 | $0 | Jan 25, 2008 |
| Oct 28, 2005 | 34499187X | RESOLVE | Non-Hazardous | WORK W/O A PERMIT. WORK NOTED: 3 METAL CHIMNEYS INSTALLED AT THE EAST EXTERIOR WALL DOES NOT APPEAR TO BE EXTENDING 3... | $500 | $0 | Feb 24, 2006 |
| Aug 12, 2000 | 38096068M | RESOLVE | Non-Hazardous | 01L12 02L12 03I11 05L11 08V01 15L11 18K12 21K12 28L11 32M07 35O02 57O02 75B05 32 PROVIDE COVERS | $2,500 | $0 | Mar 5, 2001 |