DOB violations
Boston Secor Houses Bldg 1, Bronx • Block 05263 • Lot 0040
40 records
Violations issued by the Department of Buildings.
| Issued | Violation | Type | Category | Description | Disposed |
|---|---|---|---|---|---|
| Jan 27, 2026 | FEU21203XC | C-CONSTRUCTION OTHER OPTIONAL | V*-DOB VIOLATION - DISMISSED | FAILURE TO MAINTAIN.BLDG WAS DMGD DUE TO GAS EXPLOSION ON 1/29/26 SEVERE DMG NOTED@THE 16TH&17THFLS.UNITS 16A EXT WAL... | Mar 13, 2026 |
| Jan 27, 2026 | FA21201YC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES.ON 1/24/26,A FIR E INCIDENT OCCURED WHICH DISPLACED SECTION OF ... | — |
| Jan 27, 2026 | FEU21201XC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | EMERGENCY WORK ORDER.BLDG WAS DMGD DUE TO GAS EXPLOSION ON 1/29/26 SEVERE DMGD NOTED@THE 16THH&17THFLS.WALLS OF PUBLI... | — |
| Jan 27, 2026 | FEU21202XC | C-CONSTRUCTION OTHER OPTIONAL | V*-DOB VIOLATION - DISMISSED | EMERGENCY WORK ORDER.BLDG DMGD DUE TO A GAS EXPLOSION ON 1/24/26 SEVERE DMG NOTED@THE 16TH&17TH FL.UNIT 16A EXT WALL@... | Mar 12, 2026 |
| Jan 24, 2026 | 363502H2584 | E-ELEVATOR ELEVATORREQUIRED | V-DOB VIOLATION - ACTIVE | CEASE USE 2P4106 | — |
| Jan 24, 2026 | 26-00332 | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURAL RENDERED NON-COMPLIANT. BUILDING SUSTAINED EXTENSIVE FIRE, WATER, SMOKE DAMAGED DUE TO GAS EXPLOSION AT 16... | — |
| Jan 24, 2026 | CER01CC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | — | — |
| Jan 24, 2026 | CER02CC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURE RENDERED NON COMPLIANT DUE TO EXPLOSION GAS AT 16TH & 17TH F LOORS STRUCTURAL STABILITY REQUESTED AT EXPOSU... | — |
| Jan 24, 2026 | CER03CC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURE RENDERED NON COMPLIANT . DUE TO GAS EXPLOSISON AT 16TH & 17T H FLOORS STRUCTURAL STABILITY REQUESTED INTERI... | — |
| Jan 24, 2026 | CER01CC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURED RENDERED NON COMPLIANT DUE TO EXPLOSION AT EXPSORURE #3 DAM AGED FACADE & CONSTRUCTION EUIPMENT ALSO SIDEW... | — |
| Jan 24, 2026 | 363501H2584 | E-ELEVATOR ELEVATORREQUIRED | V*-DOB VIOLATION - Resolved | CEASE USE 2P4105 | Feb 13, 2026 |
| Feb 22, 2024 | 00634 | FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED | V-DOB VIOLATION - ACTIVE | FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | — |
| Feb 22, 2024 | 00633 | FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED | V-DOB VIOLATION - ACTIVE | FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | — |
| Jun 20, 2023 | 08119 | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | V*-DOB VIOLATION - DISMISSED | VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Apr 23, 2024 |
| Apr 22, 2023 | 00038 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) | May 12, 2023 |
| Aug 21, 2022 | 00998 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021) | May 12, 2023 |
| Jun 20, 2021 | 00618 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020) | Aug 6, 2021 |
| Jun 29, 2020 | 00476 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2019) | Aug 6, 2021 |
| Dec 5, 2019 | HAZ88506 | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED | V-DOB VIOLATION - ACTIVE | — | — |
| Dec 5, 2019 | HAZ88504 | FISP-FACADE SAFETY PROGRAM FACADE REQUIRED | V-DOB VIOLATION - ACTIVE | — | — |
| Sep 6, 2019 | 00209 | ACH1-(NYCHA) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | V*-DOB VIOLATION - DISMISSED | VIO ISSUED TO NYCHA ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST | Jan 23, 2020 |
| Sep 6, 2019 | 00210 | ACH1-(NYCHA) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | V*-DOB VIOLATION - DISMISSED | VIO ISSUED TO NYCHA ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST | Jan 23, 2020 |
| Mar 27, 2018 | 00543 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2017) | Apr 3, 2018 |
| Feb 16, 2017 | 10097 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2016) | Feb 16, 2017 |
| Jan 3, 2017 | 00952 | ACH1-(NYCHA) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | V*-DOB VIOLATION - DISMISSED | VIO ISSUED TO NYCHA ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST | Feb 24, 2017 |
| Jan 3, 2017 | 00951 | ACH1-(NYCHA) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | V*-DOB VIOLATION - DISMISSED | VIO ISSUED TO NYCHA ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST | Jul 21, 2017 |
| Jan 3, 2017 | 00950 | ACH1-(NYCHA) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED | V*-DOB VIOLATION - DISMISSED | VIO ISSUED TO NYCHA ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST | Jul 21, 2017 |
| Jun 1, 2016 | 40112 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS(2015) | Jun 6, 2016 |
| Jun 1, 2015 | 00164 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS | Jun 6, 2016 |
| Dec 31, 2013 | 00194 | EARCX-FAILURE TO SUBMIT EER NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO SUBMIT AN ENERGY EFFICIENCY REPORT (EER) PER AD. CODE SEC. 28-308.4 | Jun 6, 2016 |
| Dec 31, 2013 | 20081 | FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED | V*-DOB VIOLATION - DISMISSED | FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 | Sep 2, 2014 |
| Aug 5, 2009 | LLFL01 | LL11/98-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL | V*-DOB VIOLATION - DISMISSED | (27-1021A) : FAILURE TO PROVIDE SIDEWALK SHED OR SAFETY MEASURES BC.3307.31 REMEDY: PROVIDE SIDE WALK SHED OR SAFETY ... | Jul 6, 2016 |
| Aug 1, 2008 | HAZ2132 | LL11/98-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL | V*-DOB VIOLATION - DISMISSED | — | Feb 29, 2012 |
| Nov 30, 2007 | NRF45268 | LL1198-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL | V*-DOB VIOLATION - DISMISSED | — | May 12, 2009 |
| Nov 30, 2007 | NRF45269 | LL1198-LOCAL LAW 11/98 - FACADE FACADE OPTIONAL | V*-DOB VIOLATION - DISMISSED | — | Sep 15, 2009 |
| Aug 8, 2002 | NRF52586 | L1198-LOCAL LAW 11/98 - FACADE FACADE REQUIRED | V*-DOB VIOLATION - DISMISSED | — | May 12, 2009 |
| Aug 8, 2002 | NRF52587 | L1198-LOCAL LAW 11/98 - FACADE FACADE REQUIRED | V*-DOB VIOLATION - DISMISSED | — | Sep 15, 2009 |
| Mar 26, 2002 | 12851 | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | V*-DOB VIOLATION - DISMISSED | — | Oct 8, 2002 |
| Mar 26, 2002 | 12852 | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | V*-DOB VIOLATION - DISMISSED | — | Oct 8, 2002 |
| Mar 26, 2002 | 12853 | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | V*-DOB VIOLATION - DISMISSED | — | Oct 8, 2002 |