| Apr 1, 2008 | 34639015L | RESOLVE | Hazardous | EXTERIOR FOUNDATION WALL HAS BECOME POROUS AND ALLOWING RAIN WATER INTO THE BLDG CAUSING INTERIOR DAMAGES IN THE BOIL... | $0 | $0 | Jun 27, 2008 |
| Apr 1, 2008 | 34639013H | RESOLVE | Hazardous | REISSUE: 34577912K. CONCRETE CEILING IS CRACKED LOCATED AT THE STAIRWAY "F" BETWEEN 1ST & BASEMENT LEVEL. APPROX 3' L... | $0 | $0 | Jun 27, 2008 |
| Apr 1, 2008 | 34639017P | RESOLVE | Hazardous | EXIT LIGHTS ABOVE EXIT DOOR NOT LIT AT TIME OF INSPECTION. REMEDY: REPAIR EXIT/SIGN LIGHTS ABOVE DOOR. | $0 | $0 | Jun 27, 2008 |
| Apr 1, 2008 | 34639012X | RESOLVE | Hazardous | REISSUE: 34577914Y. EXTERIOR BRICK FACADE HAS BECOME POROUS AND ALLOWING RAIN WATER TO ENTER THE BLDG CAUSING INTERIO... | $0 | $0 | Jun 27, 2008 |
| Apr 1, 2008 | 34639014J | RESOLVE | Hazardous | PARENT COORDINATOR ROOM IS MISSING A DOOR ADJACENT TO STAIRWAY "F" & REAR EXIT DOOR LEAVING THE AUDITORIUM IS MISSING... | $0 | $0 | Jun 27, 2008 |
| Jun 26, 2007 | 34577914Y | RESOLVE | Hazardous | EXTERIOR WALL HAS BECOME POROUS & ALLOWING RAIN IN THE BLDG CAUSING INTERIOR DAMAGES IN RMS 409 & 407 4 FL & RM 155 O... | $0 | $0 | Aug 17, 2007 |
| Jun 26, 2007 | 34577913M | RESOLVE | Hazardous | PLASTER IS SPALLING & CRACKED LOCATED: ROOM 409 & 407 ON 4 FL. ROOM 155 ON 1 FL (NURSES ROOM). REMEDY: PLASTER WALL &... | $0 | $0 | Aug 17, 2007 |
| Jun 26, 2007 | 34577912K | RESOLVE | Hazardous | CONCRETE CEILING IS CRACKED LOCATED AT THE STAIRWAY "F" BETWEEN 1 FL &BASEMENT. REMEDY: REPAIR CONCRETE CEILING. | $0 | $0 | Aug 17, 2007 |
| May 25, 2006 | 34526688P | RESOLVE | Hazardous | SPALLING PLASTER @ 2FL STAIRWAY D&E, CRACK @ CEILING OVER STAIR TO BOILER RM FROM 1FL TO BASEMENT (BOILER RM). REMEDY... | $0 | $0 | Aug 18, 2006 |
| May 25, 2006 | 34526687N | RESOLVE | Hazardous | MISSING/DEFECTIVE DR CLOSERS, DR RACKED @ VARIOUS LOCATIONS THROUGHOUT1ST TO 4TH FL. DEFECTIVE HINGES @ BASKETBALL GY... | $0 | $0 | Aug 18, 2006 |
| Feb 5, 2004 | 34416104P | RESOLVE | Non-Hazardous | WORK W/OUT VARIANCE.FAILURE TO CARRY OUT PERMITTED WORK IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS IN THAT CO... | $0 | $0 | Mar 26, 2004 |
| Jan 30, 2003 | 34385505R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN: DEFECT: PLAYYAR BLACK TOP SINKING 4" TO 6" CRACKS & POTHOLES THRUOUT YARD CAUSING TRIP HAZARDS T... | $0 | $0 | Apr 18, 2003 |
| Jan 30, 2003 | 34385506Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN! DEFECT: DUE TO WATER PENETRATION THRU FACADE BRICK WALL. CAUSING SEVERE PLASTER SPALLING & BUILD... | $0 | $0 | Apr 18, 2003 |
| Jan 9, 2002 | 34307509K | RESOLVE | Non-Hazardous | FAILURE TO USE PANIC HARDWARE WHERE REQUIRED. NOTED : NO PANIC HARDWARE IN GYMNASIUM 3RD FLOOR REMEDY : PROVIDE PANIC... | $0 | $0 | Apr 19, 2002 |
| Apr 10, 2001 | 34284067N | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT.EXPIRED SIDEWALK SHED PERMIT #200465148 EXP 12/31/00.REMEDY:RENEW EXPIRED PERMIT. | $0 | $0 | Sep 21, 2001 |
| Mar 21, 2000 | 34240513J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN:DEFECT IS A)THROUGHOUT FACADE PARAPET WALLS HAVE LONG CRACKS AND LEANING OUT OF PLUMB.B)WATER DAM... | $0 | $0 | Jun 9, 2000 |
| Jul 30, 1999 | 34176993Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE DURABLE MATERIAL FOR NUMERICAL SIGN INDICATING THE NUMBER OF FL 1 TO 4 ADENTIFYING TO PROVIDE 3 HI... | $0 | $0 | Oct 8, 1999 |
| Apr 5, 1999 | 34206667N | RESOLVE | Non-Hazardous | FAILURE TO MAITNAIN EXTERIOR DEFECTS ARE ROOF AND PARPET ARE LEAKING IN VARIOUS LOCATION REEMDY MAKE ALL NECESSARY RE... | $0 | $0 | Jun 25, 1999 |