Skip to content

ECB violations

3058 Godwin Terrace, Bronx • Block 05701 • Lot 0117

27 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 3, 2012 34941167H RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.PROVIDE REQUIRED CORRIDOR WIDTH PER BC-1016.2,27-369 SIDE CORRIDOR-... $0 $0 Jun 25, 2012
Mar 3, 2012 34949982K RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPT RECORDS MULTIPLE DWELLING. BASEMENT ON NORTHSIDE OCCUPANCY IS CUR... $0 $0 Jun 22, 2012
Mar 3, 2012 34941168J RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.GAS METER ROOM-BOXES,PAPER BOX ETC OIL TANK/BOILER ROOM-INSULLATION,MILLWOR... $0 $0 Jun 25, 2012
Mar 3, 2012 34941166X RESOLVE CLASS - 2 WORK W/O PERMIT.WORK NOTED:LOWERST FLR-INSTALLED WATER & WASTE LINE FOR SINK & WASHING MACHINE,CHOPPED UP FLR IN BSMN... $0 $0 Jun 25, 2012
Mar 3, 2012 34941165Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.ROOF-COPING STONED DISLODGED ROOF MISSING &/OR BROKEN CAMEL BACKS.R... $0 $0 Jun 22, 2012
Dec 11, 2008 34735846M RESOLVE CLASS - 1 FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER NOTED SECTION OF METAL FENCE APPROX 10FT WIDE IS COLLAPSED DOWN MISSING ... $5,000 $0 Jan 30, 2009
Jul 17, 2007 34592780N RESOLVE Hazardous FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. NOTED: ACCUMULATION OF CONSTRUCTION DEBRIS, PLYWOOD, WOOD PIECES AT REAR Y... $1,000 $0 Nov 16, 2007
May 1, 2007 34570312P RESOLVE Non-Hazardous FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTED:RETAINING WALL AT REAR YARD COLLAPSE... $0 $0 Sep 21, 2007
May 1, 2007 34570313R RESOLVE Hazardous FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. NOTED: ACCUMULATION OF CONSTRUCTION DEBRIS AND MATERIALS AT COURT YARD AND... $5,000 $0 Oct 26, 2007
Mar 23, 2007 34563599X RESOLVE Hazardous FAILURE TO MAINTAIN.NOTE:RETAINING WALL & REAR COLLAPSED.FENCE MISSINGAT REAR COURTYARD AT RETAINING WALL.LOOSE CONCR... $2,000 $0 Nov 23, 2007
Mar 6, 2007 34559491M RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR WALL.REAR RETAINING CONCRETE WALL HAS COLLAPSED UNTO REAR YARD OF STORE'S ON BROADWAY.RE... $0 $0 May 4, 2007
Mar 6, 2007 34559693K RESOLVE Non-Hazardous FAILURE TO MAINTAIN-REAR RETAINING WALL-LOOSE POSTS & LOOSE CHAINLINK FENCE & BROKEN CHAINLINK FENCE-OVER A 20'-0 DRO... $800 $0 May 4, 2007
Feb 6, 2007 34560340N RESOLVE Hazardous FAILURE TO MAINTAIN REAR YARD CHAIN LINK FENCE. CHAIN LINK FENCE IS LOOSE & UNSTABLE. NOT SECURED ( ATTACHED) TO POST... $2,000 -$1,767 Aug 17, 2007
Jan 4, 2007 34556006X RESOLVE Hazardous FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING NOTED:ACCUMULATION OF CONSTRUCTION DEBRIS & MATERIALS & COURTYARD & REAR YA... $1,000 $0 Oct 26, 2007
Jan 4, 2007 34556007H RESOLVE Hazardous FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS NOTED:RETAINING WALL AT REAR YARD COLLAPSE... $0 $0 May 4, 2007
Dec 2, 2006 34548187Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECTS ARE:DETACHED &MISSING SECTION OF RETAININGWALL(MASONRY BLOCK)NATURAL STONE & DIRT WALL IS... $350 $0 Nov 23, 2007
Nov 4, 2006 34540485X RESOLVE Hazardous FAILURE TO MAINTAIN REAR YARD HAZARDOUS.1-RETAINING WALL COLLASPED.2-SIDEWALK BROKEN,CRACKED,SEPARATING FROM SLABS.3-... $800 $0 Nov 23, 2007
Sep 12, 2006 34530935P RESOLVE Hazardous FAILURE TO MAINTAIN REAR AREA CHAINLINK FENCE - CHAINLINK IS LOOSE & NOT SECURED TO POSTS.REMEDY:IMMEDIATELY MAKE THE... $800 $0 Nov 23, 2007
Sep 12, 2006 34530934N RESOLVE Non-Hazardous EXIT PASSAGEWAY & CORRIDOR WIDTH DECREASED BY BABY CARRIAGES AND PLASTIC BAGS. REMEDY: REMOVE ALL CARRIAGES AND PLAST... $2,500 $0 Oct 27, 2006
Aug 2, 2006 34530550Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR WALL REAR CONCRETE RETAINING WALL HAS COLLAPSED INTO REAR YARD OF ADJACENT PROPERTY. NOW... $800 $0 Sep 22, 2006
May 10, 2006 34524561Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BRICK WALL. BRICK SPALLING & MISSING MORTAR THROUGHOUT FRONT PARAPIT WALL ENTIRE. REMEDY... $350 $0 Jun 23, 2006
Apr 27, 2006 34515950H RESOLVE Non-Hazardous WORK W/O A PERMIT-WORK NOTED:ERECTED PARTTIONS TO CREATE TWO ADDITIONAL SLEEPING AREAS-LIVING ROOM DIVIDED INTO TWO R... $500 $0 Jun 23, 2006
Apr 27, 2006 34515815P RESOLVE Non-Hazardous FAILURE TO MAINTAIN. APT C-6 KITCHEN CEILING-CRACKED AND PEELING BATHROOM-TOILET LOOSE-REPAIR JOINTS. REMEDY:MAKE SAF... $350 $0 Sep 22, 2006
Mar 1, 2006 34513651Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN REAR YARD-HAZARDOUS. REAR YARD (FOUNDATION) RETAINING WALL, REAR YARD CONCRETE SLAB AND CURB HAS ... $800 $0 Jun 16, 2006
Dec 27, 2005 34499413P RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG. DEFECT IS LARGE SECTION OF REAR CONCRETE BLOCK RETAINING WALL COLLAPSED. REMEDY: IMMEDIATEL... $350 $0 Feb 21, 2006
Jan 17, 2001 34270431N RESOLVE Non-Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY BLDG DEPT RECORDS H.P.D INFORMATION CARD (I) CERTIFICATE #1141 27 (APTS-A1-A-5)... $2,500 $0 Mar 9, 2001
Oct 20, 2000 34253792Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN: RETAINING WALL WITH RUBBLE STONE RETAINING WALL IS BROKEN WITH LOOSE STONE. HOLE IN RETAINING WA... $2,500 $0 Dec 8, 2000