Skip to content

DOB violations

Riverdale Avenue, Bronx • Block 05759 • Lot 0573

229 records

Violations issued by the Department of Buildings.

Issued Violation Type Category Description Disposed
Aug 7, 2026 20503 IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL V-DOB VIOLATION - ACTIVE REMEDY: INSTALL APPROX 285' LINEAR FEET OF SIDEWALK SHED AT EXP#1 SOUTH ELEVATION, INSTALL APPROX 45' LINEAR FEET OF ... —
Jul 27, 2026 SR0801NS C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED THE FOLLOWING CONDITIONS:DEFECT AT BALCONY SLAB-CEILI... —
Jul 27, 2026 SR20810NS C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FACADES ELEMENT FAILURE/FAILURE TO MAINTAIN:DUE TO LARGE OPEN CRACKS OF CAVITY MASONRY WALL, VERTICAL CRACKS OF CORNE... —
Jul 27, 2026 SR20811NS C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE EMERGENCY WORK ORDER DUE TO WALL SEPARATION AND CRACKING AT EXPOSURE #1 SOUTH ELEVATION. SOUTH ELEVATION. REMEDY: IMM... —
Apr 22, 2026 26-01111 C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE THE DEPARTMENT OF BUILDINGS ORDERS THAT YOU STOP ALL WORK UNDER PERMIT# 220196017 DUE TO THE APPLICANT OF RECORD WITH... —
Apr 9, 2025 SR20802DO C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION STEP CRACKS @ EXP 1 PARAPET LEVEL ALSO NUMER... —
Oct 10, 2024 SR20803DO C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE AT TIME O F INSPECTION,OBSERVED AT EXP1,3 MULTIPLE BALCO... —
Jun 23, 2024 00551 EARCX-FAILURE TO SUBMIT EER NONE V-DOB VIOLATION - ACTIVE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) —
Oct 4, 2023 01338 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Oct 4, 2023 01337 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Oct 4, 2023 01336 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Oct 4, 2023 01335 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V*-DOB VIOLATION - DISMISSED FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION Oct 6, 2023
Sep 28, 2023 SR0806NS C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE EMERGENCY WORK ORDER DUE TO MISSING BRICKS,CRACKS AND BROKEN WINDOW PA PANE IMMEDIATELY REPAIRS EXISTING UNSAFE CONDI... —
Sep 28, 2023 SR0802NS C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED MULTIPL MULTI OPENMASONRY SECT. WITH.MULTIPLE NOT SHOR... —
Jun 20, 2023 25915 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V-DOB VIOLATION - ACTIVE VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION —
Jun 20, 2023 21904 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V-DOB VIOLATION - ACTIVE VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION —
Jun 15, 2023 SR20801CC C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE IN A CODE COMPLIANT MANNER.OBSERVED MULTIPLE OPEN MASONRY SECTION WITH M... —
Apr 22, 2023 00662 EARCX-FAILURE TO SUBMIT EER NONE V-DOB VIOLATION - ACTIVE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) —
Mar 22, 2023 SR0801DJ C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTAIN BLDG EXTERIOR WALLS AND APPURTENANCES. DURING INSPECTION OBSERVED OPEN MASONRY AT EXP1. REMEDY: M... —
Aug 21, 2022 01044 EARCX-FAILURE TO SUBMIT EER NONE V-DOB VIOLATION - ACTIVE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021) —
Jun 3, 2022 16972 IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL V-DOB VIOLATION - ACTIVE .1)REPAIR SIDEWALK SHED 2) REINSTALL SAFETY NETTING —
May 20, 2022 LL0801NS C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FAILURE TO MAINTIAN BUILDING EXTERIOR WALLS/FACADE AND APPURTENANCES VIEW AT EXP1 EAST ELEVATION MISSING BRIACKS, NOR... —
Jan 5, 2022 00214 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Oct 10, 2021 00025 EARCX-FAILURE TO SUBMIT EER NONE V-DOB VIOLATION - ACTIVE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020) —
Jun 7, 2021 LLFA01LJ C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE FTM EXTERIOR BUILDING FACADE AND APPURTENANCES. AT TIME OF INSPECTION OBSERVED DEFECTIVE FACADE. EXP 1 AND EXP 3 OBJE... —
Feb 3, 2021 00214 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Jun 29, 2020 10358 EARCX-FAILURE TO SUBMIT EER NONE V-DOB VIOLATION - ACTIVE FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2019 —
May 5, 2020 14455 IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL V*-DOB VIOLATION - DISMISSED REPLACE LOOSE ,DEFECTIVE AND MISSING SIDEWALK SHED WOOD PARAPET PANELS Jan 27, 2022
Nov 8, 2019 04066 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V-DOB VIOLATION - ACTIVE VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT —
Nov 8, 2019 04067 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V-DOB VIOLATION - ACTIVE VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT —
Aug 7, 2019 00286 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Aug 7, 2019 00285 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Mar 6, 2019 00237 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Nov 14, 2018 00206 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Nov 14, 2018 00207 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
Nov 14, 2018 00208 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V-DOB VIOLATION - ACTIVE FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION —
May 31, 2018 01665 FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED V-DOB VIOLATION - ACTIVE FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 —
May 9, 2018 9027/628840 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved — Dec 16, 2022
May 9, 2018 9027/628838 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved — Dec 16, 2022
May 9, 2018 9027/628839 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved — Dec 16, 2022
May 9, 2018 9027/628841 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved — Dec 16, 2022
Apr 6, 2018 05508 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V-DOB VIOLATION - ACTIVE VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT —
Apr 6, 2018 05507 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V-DOB VIOLATION - ACTIVE VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT —
Jan 26, 2018 06875 ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED V*-DOB VIOLATION - DISMISSED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST Apr 2, 2018
Jan 26, 2018 06877 ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED V*-DOB VIOLATION - DISMISSED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST Apr 2, 2018
Jan 26, 2018 06874 ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED V*-DOB VIOLATION - DISMISSED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST Apr 2, 2018
Jan 26, 2018 06876 ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED V*-DOB VIOLATION - DISMISSED VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST Apr 2, 2018
Oct 10, 2017 HAZ87011 FISP-FACADE SAFETY PROGRAM FACADE REQUIRED V-DOB VIOLATION - ACTIVE — —
May 9, 2017 9027/602798 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved — Sep 13, 2018
May 9, 2017 9027/602796 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved — Aug 2, 2018