ECB violations
5723-5725 Broadway, Bronx • Block 05760 • Lot 0161
36 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 24, 2026 | 39178138Y | RESOLVE | CLASS - 1 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERV... | $1,630 | $1,630 | Jul 28, 2026 |
| Feb 13, 2025 | 39138392N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $625 | $0 | Oct 3, 2025 |
| Feb 12, 2025 | 39138231M | RESOLVE | CLASS - 1 | I NOTED AN ODOR OF GAS UPON ENTERING THE GAS METER ROOM, NOTIFIED CON ED, WHOSE TECHNICIAN DETERMINED THERE WAS A LEA... | $2,500 | $0 | Jan 27, 2026 |
| Jan 23, 2024 | 39104040Y | RESOLVE | CLASS - 2 | HOLE PENETRATION/CIRCULAR CUT-OUT OF THE FIRE STOPPING/SHEET ROCK IN THE CEILING OF THE BOILER MECHANICAL ROOM, CELLA... | $0 | $0 | Mar 29, 2024 |
| Jan 23, 2024 | 39104038P | RESOLVE | CLASS - 2 | EMERGENCY EXIT DOORS DO NOT SELF-CLOSE ROOF LEVEL AND THROUGHOUT BUILDING., REPAIR/REPLACE DOOR | $0 | $0 | Aug 23, 2024 |
| Jan 22, 2024 | 38275513P | RESOLVE | CLASS - 2 | 2-L-10=DEFECTIVE OUTSIDE COMMUNICATION(PHONE) DIAL, BUT NO ANSWER; MUST REPAIR. (THIS IS A CLASS 2 VIOLATION) ALARM S... | $0 | -$10 | Mar 29, 2024 |
| Aug 17, 2022 | 39068239X | RESOLVE | CLASS - 2 | AS PER ONE VIESSMAN BOILER IN CELLAR. CONDENSING DRAIN LEAKING INTO BOILER AND ONTO FLOOR. | $0 | $0 | Oct 7, 2022 |
| May 9, 2022 | 39062500N | RESOLVE | CLASS - 1 | I OBSERVED IN THE ELECTRICAL EQUIPMENT ROOM THE INSTALLATION OF DATA EQUIPMENT OTHER THAN ELECTRICAL DISTRIBUTION EQU... | $300 | $0 | Jul 15, 2022 |
| May 9, 2022 | 39062501P | RESOLVE | CLASS - 2 | I OBSERVED IN THE ELECTRICAL EQUIPMENT ROOM THE DISCONNECT SWITCH FOR METER BANK "B" BLOCKED AND MADE INACCESSIBLE BY... | $0 | $0 | Jul 15, 2022 |
| Jun 5, 2019 | 35434202Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN ACTIVE COMPLIANT MANNER. OBSERVED IN THE BOILER ROOM IN THE CELLAR ONE BOILER FOR THE... | $0 | $0 | Aug 2, 2019 |
| May 7, 2019 | 39002688J | RESOLVE | CLASS - 2 | PRESSURE RELIEF VALVE LEAKING, NO COMPOUND GAGE ON BOILER SUPPLY PIPING. CORRECT ALL VIOLATING CONDITIONS, SUBMIT A C... | $0 | $0 | Jun 21, 2019 |
| Apr 16, 2019 | 38269209J | RESOLVE | CLASS - 2 | 67X10;(67,X,10)OUTSIDE COMMUNICATION NOT WORKING IN CAR. | $312 | $0 | Jul 12, 2019 |
| Jan 9, 2019 | 35359774M | RESOLVE | CLASS - 2 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN DECEMBER 03,2018.A ELECTRICAL VIOLATION WAS ISSU... | $625 | $0 | Mar 15, 2019 |
| Dec 3, 2018 | 35362098N | RESOLVE | CLASS - 1 | FAILURE TO INSTALL GROUND ELECTRODE CONDUCTOR IN ACCORDANCE WITH SECTION.OBSERVED GROUND ELECTRODE CONDUCTOR INSTALLE... | $1,200 | $0 | Jan 18, 2019 |
| Dec 3, 2018 | 35372862Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. OBSERVED ON ROOF FOR THE SIXTH FLOOR APPROX THREE INCHES OF ... | $0 | $0 | Jan 18, 2019 |
| Dec 3, 2018 | 35362099P | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY LABEL DISCONNECTS.OBSERVED IN ELECTRICAL EQUIPMENTROOM,SEVERAL 400 AMP SERVICE SWITCHES WITH NO D... | $0 | $0 | Jun 28, 2019 |
| Dec 3, 2018 | 35373075Y | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED THE INSTALLATION OF BRANCH CIRCUIT WIRING; OUTLET BOXES FOR SWITCHES RECEP... | $1,600 | $0 | Mar 15, 2019 |
| Jul 23, 2018 | 32097410P | RESOLVE | CLASS - 2 | 32A,50A,50B,50C-AS PER CLASS 2 (B254) 28-301.1 FAILURE TO MAINTAIN. 50A)BOILER ROOM DOOR NOT SELF-CLOSING. 50B)DOMEST... | $0 | $0 | Sep 7, 2018 |
| Jun 13, 2017 | 35238857R | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.NOTE:O BSERVED SITE-FACADE AT EXPO #1 COMPLETELY ENCLO... | $4,800 | $0 | Aug 4, 2017 |
| May 3, 2017 | 35238699K | RESOLVE | CLASS - 1 | SIDEWALK SHED WHERE REQUIRED. NOTED: @ TIME OF INSP OF A 7 STORY BLDG @ ROOF LEVEL APPROX 70FT IN HEIGHT, CONSTRUCTIO... | $4,800 | $0 | Jun 30, 2017 |
| Dec 14, 2016 | 35212247Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN GUARDRAILS.NOTED:AT 7TH FLOOR LEVEL WORKERS ARE NOT TIED OFF AND THERE ARE NO GUARDRAILS IN PLACE... | $1,200 | $0 | Feb 3, 2017 |
| Dec 14, 2016 | 35212246M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSON AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION.NOTED:WORKERS AT 7TH FLOOR INSTALLING... | $10,000 | $0 | Feb 3, 2017 |
| Dec 14, 2016 | 35212555X | RESOLVE | CLASS - 2 | HOUSEKEEPING: NOT MAINTAINED. NOTED: AT 6TH FLOOR LEVEL THERE IS ASSORTED CONSTRUCTION DEBRIS EQUIPMENT AND TRASH.HOU... | $0 | $0 | Feb 3, 2017 |
| Dec 14, 2016 | 35212556H | RESOLVE | CLASS - 1 | FAILURE TO KEEP JOB SAFE. AT TIME OF INSPECTION REGISTERED SUPER JOSEPH MARTINO HAS NO RECORD OF BEING ON SITE. THE F... | $1,600 | $0 | Apr 14, 2017 |
| Dec 14, 2016 | 35212554Y | RESOLVE | CLASS - 1 | 3303.4.4 AREAS OPEN TO PERSONS OTHER THAN WORKERS.NOTED:EXPO#1ACTIVE LOADING OPERATIONS IN PROGRESS WITH A "LULL"LOAD... | $1,600 | $0 | Mar 31, 2017 |
| Dec 14, 2016 | 35212248X | RESOLVE | CLASS - 1 | 3301.2 SAFETY MEASURES AND STANDARDS:NO OVERHEAD PT.NOTED:ACTIVE SITE MASONARY WORK AT 7TH FLOOR LEADING EDGE.AT EXPO... | $1,600 | $0 | Mar 31, 2017 |
| Dec 14, 2016 | 35212249H | RESOLVE | CLASS - 1 | 3301.1.1RESPONSIBILITY FOR SAFETY:NO OVERHEAD BLOCKING NOTED:ACTIVE 7 STORY BUILDING MASONARY WORK AT LEAD EDGE.THERE... | $1,600 | $0 | Mar 31, 2017 |
| Dec 14, 2016 | 35212552K | RESOLVE | CLASS - 1 | 3301.6.1 DESIGN:NO DESIGN DRAWING FOR NEEDLE BEAM PLATFORM AT EXPO #4.OVER AD PROPERTY OBSRVED NEEDLE BEAM WITH NO RE... | $1,600 | $0 | Mar 31, 2017 |
| Dec 14, 2016 | 35212550R | RESOLVE | CLASS - 1 | SMOKING AT CONSTRUCTION/DEMOLITION SITE.NOTE:WORKER AT 7TH FLOOR LEVEL W/NO HARD HAT WAS SMOKEY AND CIGARETTE WHILE I... | $2,400 | $0 | Feb 3, 2017 |
| Dec 14, 2016 | 35212553M | RESOLVE | CLASS - 1 | BC3301.1.1 RESPONSIBILTY FOR SAFETY: NO REBAR CAPS NOTED: AT 7TH FLR LEVEL 6-8 WORKERS INSTALLING MASONRY BLOCKS/BRIC... | $1,600 | $0 | Feb 3, 2017 |
| Dec 14, 2016 | 35212551Z | RESOLVE | CLASS - 2 | 3301.1.2 FIRE CODE.FIRE EXTINGUISHER NOTE:AT 5-6-7 FLOOR OF ACTIVE CONSTRUCTION SITE THERE WERE NO FIRE EXTINGUISHERS... | $400 | $0 | Feb 3, 2017 |
| Dec 14, 2016 | 35212245K | RESOLVE | CLASS - 1 | 3307.6 SIDWALK SHEDS:MISSING SECTIONS.NOTED:ACTIVE S6 MASSONARY WORK IN PROGRESS @7TH FL AT EXPO#1.THE SIDWALK SHED W... | $1,600 | $0 | Mar 31, 2017 |
| Aug 19, 2016 | 35170494Z | RESOLVE | CLASS - 2 | SUBMITTAL OF CONSTRUCTION DOCUMENTS AS NOTED: AT TIME OF INSPECTION ATAN ACTIVE JOB SITE OBSERVED NEW BUILDING UNDER ... | $400 | $0 | Nov 4, 2016 |
| Aug 19, 2016 | 35170493R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOB S... | $2,400 | $0 | Feb 3, 2017 |
| Mar 1, 2016 | 35165235H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE PROTECTION AT RIDES OF EXCAVATION. 45 ANGLE OF REPOSE AS SHOWN ON APPROVED(50 E)PLANS(PG 102.00)DA... | $2,400 | $0 | Jul 29, 2016 |
| Mar 1, 2016 | 35165236J | RESOLVE | CLASS - 1 | SEC. 48 FAILURE TO ADEQUATELY SUPERVISE WORK AT A CONSTRUCTION SITE;SOAS TO MAINTAIN A SAFE CONST SITE & ENSURE COMPL... | $1,630 | $0 | Oct 7, 2016 |