ECB violations
Dash Place, Bronx • Block 05779 • Lot 0801
18 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 27, 2026 | 39186217M | RESOLVE | CLASS - 1 | OBSERVED IN LAUNDRY ROOM ON 1ST FLOOR DRYER VENTS NOT VENTED PROPERLY. PER BC 28-301.1 FAILURE TO MAINTAIN BUILDING I... | $2,530 | $2,530 | Jul 31, 2026 |
| Apr 16, 2026 | 39184861Y | ACTIVE | CLASS - 2 | MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED IN THE CELLAR OUTSIDE H.W. / BOILER RM N... | $830 | $830 | Jul 17, 2026 |
| Apr 16, 2026 | 39184827K | ACTIVE | CLASS - 2 | CLASS 2 VIOLATIONS: 1) IN-CAR HANDRAIL MISSING AS REQUIRED BY ASME A17.1 2.14.1.7. REMEDY: INSTALL HANDRAIL. 2) EMERG... | $655 | $655 | Jul 17, 2026 |
| Apr 16, 2026 | 39184828M | ACTIVE | CLASS - 1 | CLASS 1 - CEASE USE: 1) FIRE FIGHTER SERVICE PHASE II INOPERATIVE - KEY ROTATES 360B0 WITHOUT ACTIVATING PHASE II AS ... | $1,280 | $1,280 | Jul 17, 2026 |
| Apr 16, 2026 | 39184860M | ACTIVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN THE BASEMENT ON NEW PANEL INSTALLED ALSO THRU OUT BUILDING THE INSTALLA... | $2,530 | $2,530 | Jul 17, 2026 |
| Apr 14, 2025 | 39144789M | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING EXIT DOOR. LOCATED AT BASEMENT LEVEL. POTENTIAL HAZARD., REPAIR... | $0 | $0 | Jun 20, 2025 |
| Apr 14, 2025 | 39144788K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED AT BASEMENT LEVEL. 8 GARAGE PALES OBSTRUCTING MAIN EXIT PAS... | $1,250 | $0 | Dec 5, 2025 |
| Apr 14, 2025 | 39144790J | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED EXCESSIVE UNSAFE STORAGE IN THE BOILER ROOM. (REFRIGER... | $0 | $0 | Dec 5, 2025 |
| Sep 6, 2024 | 35686173P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENACES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #1 SOUT... | $0 | $0 | Nov 15, 2024 |
| Feb 27, 2023 | 35670676K | RESOLVE | CLASS - 3 | FAILURE TO POST EXTERIOR WALL CONDITION CERTIFICATE AS REQUIRED UNDER 1RCNY 103-04. AT TIME OF INSPECTION CERTIFICATE... | $500 | $0 | May 5, 2023 |
| Dec 9, 2022 | 37024881X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 2, 2023 |
| Jul 1, 2015 | 35123504L | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT. GROUND FLOOR RESTAURANT: SUB PANEL 200AMP,BRANCH CIRCUIT WIRING,RECEPTACLES OUTLETS,SWI... | $0 | $0 | Mar 18, 2016 |
| May 25, 2010 | 38211167Z | RESOLVE | CLASS - 2 | 15M07,17H11,41I11,41T07,42D06. 42D- PROPERLY SECURE TIMER RELAY | $0 | $0 | Jul 16, 2010 |
| Dec 19, 2000 | 38109966Y | RESOLVE | Non-Hazardous | 3I11,10B11,14M7,28H12,30O2,46#7,57O2.3-CAR PANEL DAMAGE.10-CAR BUTTON LIGHT NOT WORKING.14-NO CERTIFICATE FRAME.28-WO... | $0 | $0 | Feb 9, 2001 |
| Dec 19, 2000 | 38109967X | RESOLVE | Non-Hazardous | 3I11,10B11,14M7,28H12,30O2,46#7,57O2.3-CAR PANEL DAMAGED.10-CAR BUTTON LIGHT NOT WORKING.14-NO CERTIFICATE FRAME.28-W... | $0 | $0 | Feb 9, 2001 |
| Feb 18, 2000 | 38094329M | RESOLVE | Non-Hazardous | 22Q6. | $180 | $0 | Jul 14, 2000 |
| Feb 18, 2000 | 38094330J | RESOLVE | Non-Hazardous | 7L11,31Q3. *31 WIRING FOR GATE. | $0 | $0 | Jul 14, 2000 |
| Jul 21, 1997 | 38061775L | RESOLVE | Non-Hazardous | 75U03O30O35O62O57O | $1,000 | $0 | Nov 14, 1997 |