ECB violations
Cambridge Avenue, Bronx • Block 05791 • Lot 0388
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 1, 2024 | 37029714L | RESOLVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMEN... | $1,250 | -$1,250 | Jun 20, 2025 |
| Sep 19, 2024 | 35683110Y | RESOLVE | CLASS - 2 | FAILURE TO CONDUCT OR FILE A FINAL INSPECTION OF PERMITTED WORK WITH THE DEPARTMENT. ATOI OBSERVED WORK ON FACADE COM... | $625 | $0 | Feb 14, 2025 |
| May 7, 2021 | 35559963H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:AT TIME OF INSPECTION OBSERVED DEFECTIVE FACADE.R... | $0 | $0 | Jul 30, 2021 |
| Mar 10, 2021 | 35542509R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES NOTE AT THE TIME OF MY INSPECTION OBSERVED DISLODGE ME... | $1,250 | $0 | Jun 4, 2021 |
| Sep 16, 2019 | 35438893K | RESOLVE | CLASS - 1 | BC 3314.15.2 HANGERS OR STIRRUPS. NOTE: AT THE TIME OF INSPECTION WITHA COMPLAINT OBSERVED ACTIVE JOB SITE FOR FACADE... | $2,530 | $0 | May 22, 2020 |
| Jul 15, 2019 | 35439723M | RESOLVE | CLASS - 1 | 3314.10.10 FAILURE TO PROVIDE BEARING BLOCKS FOR C-HOOK SUPPORT. AT TIME OF INSPECTION OF AN ACTIVE 7STORY ALERATION ... | $625 | $0 | Sep 13, 2019 |
| Jul 15, 2019 | 35439722K | RESOLVE | CLASS - 1 | 3314.4.3.2 FAILURE TO PROVIDE INSTALLATION INSPECTION FOR SUSPENDED SCAFFOLD. AT TIME OF INSPECTION OF AN ACTIVE 7 ST... | $625 | $0 | Sep 13, 2019 |
| Apr 17, 2007 | 38166109K | RESOLVE | Non-Hazardous | 66Z09, 10A07 10A07 REMOVE ZIP SCREWS & PROVIDE PROPER SCREWS FOR CAR DOOR GIBS | $350 | $0 | Jun 15, 2007 |
| Nov 4, 2004 | 34447841R | RESOLVE | Non-Hazardous | PIPING AND/OR EQUIPMENT INSTALLED IMPROPERLY. RAN FLEX CONNECTORS TO DRYERS IN LAUNDRY ROOM. MUST BE HARD PIPED. REME... | $350 | $0 | Dec 17, 2004 |
| May 17, 2002 | 34326966J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT NOTED: PARAPET WALL IS CURRENTLY BEING REMOVED ALONG THE ENTIRE BUILDIG. THERES A HAEAVY ... | $0 | $0 | Sep 6, 2002 |
| Nov 28, 2001 | 34260526R | RESOLVE | Hazardous | USE OF ROGGING EQUIPMENT(SCAFFOLD)WITHOUT A SPECIAL RIGGERS LICENSE USE OD SCAFFOLDING WITHOUT A CENTER IRON SUPPORT.... | $0 | $0 | Feb 1, 2002 |
| Oct 10, 2001 | 34305882J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN ( WORK INPROGRESS ) DEFECT NOTED: BRICKWORK ( POINTING ) MANSORY ABOVE 5TH STORY REAR OF BUILDING... | $180 | $0 | Jan 18, 2002 |
| Feb 22, 2000 | 38094335Z | RESOLVE | Non-Hazardous | 13M07,50Y11,50F11,37G12. | $0 | $0 | Apr 14, 2000 |
| Apr 21, 1999 | 38086579P | RESOLVE | Non-Hazardous | 50Y11,50F11,22Q3,47H12,38Q3,57O2. -22 PROPERLY SEAL TOP EMERG. EXIT | $2,500 | $0 | Jun 11, 1999 |
| Aug 5, 1997 | 38060585X | RESOLVE | Non-Hazardous | 75U,50Y, 50-SEAL OIL LEAK MAIN MACHINE. | $100 | $0 | Sep 26, 1997 |