ECB violations
Arlington Avenue, Bronx • Block 05912 • Lot 0091
19 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 19, 2022 | 39072320P | ACTIVE | CLASS - 2 | NO GFCI PROTECTION IN THE KITCHEN THROUGHOUT ALL APARTMENTS, INSTALL GFC1 PROTECTION | $2,400 | $2,400 | May 12, 2023 |
| Oct 7, 2022 | 35655354M | ACTIVE | CLASS - 1 | ELECTRICAL WORK W/O PERMIT.OBSERVED IN APT #8C 3 NEW RECEPTACLE OUTLETS INSTALLED AT KITCHEN COUNTERTOP W/O ELECTRICA... | $800 | $0 | May 12, 2023 |
| Apr 8, 2016 | 35141957N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. TIME OF INSPEC TION 11:45 AM ABOVE THE DATE. AT TIME OF INSPEC... | $500 | $0 | Jul 15, 2016 |
| Nov 1, 2011 | 34912804Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE REQUIRED PER BC 27-95... | $0 | $0 | Jan 26, 2012 |
| Jun 30, 2011 | 34898359L | RESOLVE | CLASS - 1 | SEC. 3314.1.2. NOTIFICATION OF SCAFFOLDING ACCIDENTS THE PERMIT HOLDEROR PERSON DIRECTLY IN CHARGE OF ANY SCAFFOLDING... | $1,600 | $0 | Oct 14, 2011 |
| Jun 30, 2011 | 34898360Z | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. + STOP WORK ORDER ISSUED + - COU... | $0 | $0 | Aug 19, 2011 |
| Mar 8, 2010 | 38209758H | RESOLVE | CLASS - 2 | 71X10.98BB5 | $0 | $0 | Apr 30, 2010 |
| Nov 19, 2007 | 38179819H | RESOLVE | Non-Hazardous | 38O02,51M11,59Q03,85BB05,86BB05. 51-M-11 REPLACE SPIN OUTS FOR HOIST ROPES. | $350 | $0 | Mar 21, 2008 |
| Jul 17, 2006 | 34530375X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN PLUMBING STORM SEWER IN FRONT OF GARAGE IS BLOCKEDWITH DEBRIS FROM WET SAW WORK DONE IN GARAGE.RE... | $0 | $0 | Sep 1, 2006 |
| Sep 30, 2004 | 34447597Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED. NOSPRINKLERS OVER DRYERS IN LAUNDRY ROOM. REMEDY:... | $0 | $0 | Feb 25, 2005 |
| Sep 30, 2004 | 34447596M | RESOLVE | Non-Hazardous | PIPING AND/OR EQUIPMENT INSTALLED IMPROPERLY, RAN FLEX CONNECTORS TO DRYERS IN LAUNDRY ROOM. MUST BE HARD PIPED. NO P... | $0 | $0 | Feb 25, 2005 |
| Feb 27, 2004 | 34423628L | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT PERMIT EXPIRED WORK NOTED AT INTERIOR BUILDING LOT # 91 AT 6 FL APT 6G,6H CONSTRUCTION WORK UND... | $200 | $0 | Jul 16, 2004 |
| Oct 13, 2000 | 34253781Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT NOTED:MASONRY CONCRETE FLOOR IS BROKEN AND SPALLING.HOLES THROUGHOUT GARAGE.TEMPORARY STEE... | $180 | $0 | Dec 8, 2000 |
| Mar 17, 1998 | 38071816H | RESOLVE | Non-Hazardous | 30P5#37O50Y57O30O 30-NO ACCESS TO CAR TOP 5-CAR DOOR DON'T OPEN PULLEY | $180 | $0 | May 8, 1998 |
| Mar 17, 1998 | 38071817J | RESOLVE | Non-Hazardous | 35A30P50Y37O57O30O74M 30-NO ACCESS TO CAR TOP 35-PATCH MOTOR RM WALL 74-FAN GUARD MISSING IN CAB. | $180 | $0 | May 8, 1998 |
| Jul 2, 1997 | 34155002L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN THE ROOF MOUNTED COOLING TOWER AND ITS SUPPORTING STEEL DONAGE: THE VIBRATION ISOLATORS FROM UNDE... | $350 | $0 | Nov 14, 1997 |
| Aug 19, 1996 | 34139539L | RESOLVE | Hazardous | FAILURE TO MAINTAIN THE ROOF MOUNTED COOLING TOWER THE ITS SUPPORTING STEEL DONAGE THE VIBRATION ISOLATORS FROM UNDER... | $800 | $0 | Jun 13, 1997 |
| Jul 8, 1992 | 34073812Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT IS: CONCRETE WALKS AT FRONT SOUTH PORTION ARE BROKEN, DEFECTIVE & SINKING. REMEDY-REPAIR,... | $1,000 | $0 | Sep 11, 1992 |
| May 15, 1992 | 34057567J | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSAUNT TO RULE RCNY 32-036(5) INDICATION CORRECTION... | $0 | $0 | Aug 14, 1992 |