ECB violations
5400-5444 Arlington Avenue, Bronx • Block 05950 • Lot 0475
19 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 15, 2024 | 39534414J | ACTIVE | CLASS - 2 | 3307.6.4.10 FOUNDING. AT TIME OF INSPECTION I OBSERVED 6 STORY RESIDENTIAL BUILDING SIDEWALK SHED IN PLACE EXPOSURE 1... | $2,530 | $0 | Jan 31, 2025 |
| Dec 19, 2022 | 35670126X | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED SAFETY MEASURES TO PROTECT PUBLIC SAFETY. NOTE FISP3 UNSAFE NOTIFICATION#911999 DATED ON ... | $2,400 | $0 | Jun 23, 2023 |
| Oct 19, 2022 | 37023219R | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B AND 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTE... | $6,250 | $6,250 | Feb 3, 2023 |
| Jan 21, 2022 | 35538241N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES.OBSERVED MULTIPLELARGE CRACKS ON TWO SIDES OF A BIG MASONRY,GRIM... | $25,000 | $0 | Apr 15, 2022 |
| Dec 7, 2021 | 35640273Z | ACTIVE | CLASS - 3 | AC28-302.1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT.NOTE:ATOI,EXTERIOR WALL CONDITION CERT WASNT POSTED IN INTERIOR ... | $500 | $96 | Mar 4, 2022 |
| Dec 7, 2021 | 35640272R | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE/WALLS&APPURTENANCES.NOTE:ATOI,OBSERVED@EXP3,E ELEVATION STEP CRACKING IN CHI... | $12,500 | $0 | Mar 4, 2022 |
| Jun 1, 2021 | 37021545N | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT OF CRITIAL EXAMINATION DOCUMENTING CONDITION OF EXTERIO... | $5,000 | -$5,000 | Oct 15, 2021 |
| May 20, 2020 | 37019004H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT CRITICALEXAMINATION DOCUMENTING CONDITION OF EXTERIOR W... | $5,000 | $0 | Aug 21, 2020 |
| Jul 8, 2019 | 38270422R | ACTIVE | CLASS - 2 | 26B11,02X10,52M07,59B01; (26-B)REPLACE WITH MANUAL RESET SWITCH(02-X)REPAIR IN CAR PHONE(52-M)PROVIDE TAG(59-B)ADJUST... | $3,125 | $3,125 | Aug 30, 2019 |
| Oct 15, 2018 | 37012749K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $3,125 | -$3,125 | Mar 1, 2019 |
| Aug 11, 2016 | 37001200J | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $5,000 | $0 | Feb 3, 2017 |
| Mar 30, 2016 | 35174245X | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE. NOTED: EAST ELEVATION EXP#1 (NETHERLAND AV) STEP CARCK AND LOOSE MORTAR AT ... | $500 | $0 | Aug 19, 2016 |
| Oct 28, 2015 | 36023476L | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION PF EXTERIOR WALLS... | $2,000 | $0 | Aug 22, 2016 |
| Oct 21, 2014 | 36019977H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $800 | $0 | Jan 16, 2015 |
| Aug 29, 2003 | 32043035Z | RESOLVE | Non-Hazardous | 50A 50A BOILER NOTIN USE MUST BE PROPERLY DISCONNECTED OR MUST BE MAINTAINED FOR SAFE OPERATION IF BOILER IS TO BE DE... | $180 | $0 | Oct 17, 2003 |
| Jan 9, 2001 | 38108511N | RESOLVE | Non-Hazardous | 75U05/75-PERFORMED AND FILE FOR 5YR TEST. | $0 | $0 | Feb 16, 2001 |
| Jan 9, 2001 | 38108512P | RESOLVE | Non-Hazardous | 75U05/08V01/75 PERFORMED AND FILE FOR 5YR, TEST | $0 | $0 | Feb 16, 2001 |
| Jan 9, 2001 | 38108510L | RESOLVE | Non-Hazardous | 75U05/75-PERFORM AND FILE FOR 5YR. TEST. | $0 | $0 | Feb 16, 2001 |
| Dec 11, 1999 | 38092638R | RESOLVE | Non-Hazardous | 46K,38Q,50Y,37L,63L. LUB HOIST CABLES, REMOVE PAPER FROM RELAYS. REMOVE BLOCK FROM GOVERNOR TENSION SHEAVE. | $0 | $0 | Feb 11, 2000 |