| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 25, 2025 | 37033885H | ACTIVE | CLASS - 2 | 1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103... | $6,250 | $6,250 | May 28, 2025 |
| Feb 25, 2025 | 37033870P | ACTIVE | CLASS - 2 | 1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103... | $6,250 | $6,250 | May 28, 2025 |
| Feb 25, 2025 | 37033858M | ACTIVE | CLASS - 2 | 1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103... | $6,250 | $6,250 | May 28, 2025 |
| Feb 25, 2025 | 37033884X | ACTIVE | CLASS - 2 | 1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103... | $6,250 | $6,250 | May 28, 2025 |
| Jun 17, 2024 | 37028922L | ACTIVE | CLASS - 2 | A.C. 27-929.1, FAILURE TO COMPLETED THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINK... | $6,250 | $0 | Dec 5, 2024 |
| Apr 11, 2024 | 37028111H | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Dec 4, 2024 |
| Apr 11, 2024 | 37028116R | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Dec 4, 2024 |
| Feb 28, 2023 | 37025422L | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $6,250 | $0 | Jan 8, 2024 |
| Nov 1, 2021 | 37022546J | ACTIVE | CLASS - 2 | FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPA... | $1,250 | $0 | Apr 27, 2022 |
| Mar 30, 2021 | 37020805X | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $6,250 | $0 | Aug 25, 2021 |
| Jul 13, 2020 | 37019944H | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $3,125 | $0 | Dec 23, 2020 |
| Nov 15, 2019 | 37016869N | ACTIVE | CLASS - 2 | A.C 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER... | $1,250 | $0 | Nov 9, 2020 |
| Oct 5, 2018 | 35366766H | RESOLVE | CLASS - 1 | SEC. 28-111.1 TEMPORARY MODEL CERTIFICATE. NOTE: AT THE TIME OF MY INSPECTION OF A 12 STY BLDG UNDER ALTERATION CONST... | $2,500 | $0 | Dec 31, 2018 |
| Oct 5, 2018 | 35366767J | RESOLVE | CLASS - 2 | COLLECTION & CONTAINMENT. NOTE: AT THE TIME OF MY INSPECTION OF A 12 STY UNDER ALTERATION CONSTRUCTION WORK IN PROGRE... | $2,500 | $0 | Dec 31, 2018 |
| Oct 5, 2018 | 35366769N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTE:AT THE TIME OF MY INSPECTION I ... | $5,000 | $0 | Mar 25, 2019 |
| Oct 5, 2018 | 35366768L | RESOLVE | CLASS - 1 | SEC. 3307.7.2 GATE. NOTE: AT THE TIME OF MY INSPECTION I OBSERVED GATE AT EXP#1 BEING USE FOR EGRESS & INGRESS OF SIT... | $2,500 | $0 | Dec 31, 2018 |
| Oct 5, 2018 | 35366765X | RESOLVE | CLASS - 1 | SEC. 3301.6 DESIGN SIZES & CAPACITY OF MATERIALS,STRUCTURES,TEMPORARY CONSTRUCTION & EQUIPMENT. NOTE: AT THE TIME OF ... | $2,500 | $0 | Dec 31, 2018 |
| Oct 5, 2018 | 35366763M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE AND MAINTAIN SAFEY EQUIPMENT MEASURES AND TEMPORARY CONSTRUCTION.NOTE:RESPONDING TO COMPLAINT#36... | $10,000 | $0 | Jul 24, 2019 |
| Oct 5, 2018 | 35366764Y | RESOLVE | CLASS - 1 | SEC.. 3303.12 HOIST/ELEVATOR IN READINESS. NOTE: AT THE TIME OF MY INSPECTION OF A 12 STY BLDG UNDER ALTERAITON APPRO... | $2,500 | $0 | Dec 31, 2018 |
| Sep 6, 2018 | 38264860X | RESOLVE | CLASS - 1 | 97R17 ILLEGAL USE OF THIS DEVICE. FILE FOR A CONSTRUCTION TEMP FOR THIS DEVICE. | $0 | $0 | Nov 26, 2018 |
| Jun 25, 2018 | 35300591N | RESOLVE | CLASS - 1 | BC3303.7.2 FIRE EXTINGUISHERS. IN RESPONSE TO AN INCIDENT WHERE A WORKER FELL FROM A 2ND STORY STRUCTURAL STEEL. OBSE... | $2,500 | $0 | Aug 27, 2018 |
| Jun 25, 2018 | 35336054M | RESOLVE | CLASS - 1 | SITE SAFETY FAILURE TO NOTIFY (INCIDENT IMMEDIATELY). IN RESPONSE TO AN INCIDENT, WHERE A WORKER FELL FROM A HEIGHT O... | $0 | $0 | Oct 24, 2018 |
| Jun 25, 2018 | 35300590L | RESOLVE | CLASS - 1 | SUPPORTED PIPE SCAFFOLD MUDSILLS. IN RESPONSE TO AN INCIDENT WHERE A WORKER FELL FROM 2ND STORY OF STRUCTURAL STEEL, ... | $2,500 | $0 | Aug 29, 2018 |
| Jun 25, 2018 | 35300587K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN SAFE OPERATIONS. IN RESPONSE TO AN INCIDENT WHERE A WORKER FELL FROM 2 STORIES OF STEEL STRUCTURE... | $10,000 | $0 | Aug 27, 2018 |
| Jun 25, 2018 | 35300589Y | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIALS. IN RESPONSE TO AN INCIDENT WHERE A WORKER FELL FROM 2ND STORY OF STRUCTURAL ... | $2,500 | $0 | Aug 27, 2018 |
| Mar 26, 2018 | 35314371Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33. AT THE TIME OF MY INSPECTION IT WAS OBSERVED TH... | $625 | $0 | Jul 9, 2018 |
| Mar 26, 2018 | 35314372K | RESOLVE | CLASS - 1 | SEC. 1704.1.1 FAILURE TO FILE A SPECIAL STATEMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUENACE & PRIOR TO START OF WOR... | $625 | $0 | Jul 9, 2018 |
| Mar 26, 2018 | 35314370R | RESOLVE | CLASS - 2 | SEC. 3307.3.2 FAILURE TO PROVIDE REQUIRED LOT LINE CONSTRUCTION FENCE. AT THE TIME OF MY INSPECTION IT WAS OBSERVED T... | $0 | $0 | May 21, 2018 |
| Jun 7, 1995 | 34122999L | RESOLVE | Unknown | FAILURE TO PROVIDE ADEAVATORY DURABLE MATERIAL FOR ELEVATOR LANDING SIGNS THROUGHOUT FLOORS 2-12 AND BASEMENT.REMEDY-... | $0 | $0 | Jul 20, 1995 |
| Jun 7, 1995 | 34122998J | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84-CERTIFYING TO THE ISSTALLATION OF REWIRED FIRE PROTECTION... | $0 | $0 | Jul 24, 1995 |
| Mar 19, 1991 | 34054658L | RESOLVE | Non-Hazardous | SIGNS AT ELEVATOR LANDINGS MISSING OR DEFECTIVE. THE DIAGRAMS POSTED AT ELEVATOR BANK J AREA ARE DEFECTIVE IN THAT TH... | $0 | $0 | May 6, 1991 |
| Mar 19, 1991 | 34054657J | RESOLVE | Non-Hazardous | STAIR RE-ENTRY SIGNS MISSING OR DEFECTIVE. NOT POSTED ON INTERIOR OFSTAIRWAY "RE-ENTRY" ON THE FOLLOWING AREA'S 12B,1... | $0 | $0 | May 6, 1991 |