Maintenance code violations
89-91 Columbia Heights, Brooklyn • Block 00219 • Lot 0004
17 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Feb 23, 2022 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | May 29, 2022 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Oct 14, 2009 | B | NOV SENT OUT | D26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF MISCELLANEOUS ITEMS BOILER ROOM CELLAR. | — | Nov 18, 2009 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTERBOARD CEILING CELLAR CENTER. | — | Nov 18, 2009 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING BOILER ROOM CELLAR. | — | Nov 18, 2009 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKWORK & CEMENT MORTAR AROUND MET... | — | Nov 18, 2009 |
| Oct 14, 2009 | A | NOV SENT OUT | D26-10.01 ADM CODE REFIT ENTRANCE DOOR BOILER ROOM CELLAR. | — | Jan 17, 2010 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 1ST TO 5 ... | — | Nov 18, 2009 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-10.01 ADM CODE PROPERLY SECURE THE LOOSE WOOD TREADS & RISERS 4 5 & 6 UP FROM BOTTOM 1 TO 2 STY PUBLIC HALL. | — | Nov 18, 2009 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEP... | 3 | Nov 18, 2009 |
| Oct 14, 2009 | A | NOV SENT OUT | D26-41.15 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Jan 17, 2010 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CRACKED CEMENT ORNAMENTAL AWNING OVER ENTRANCE DOOR TO BLDG. | — | Nov 18, 2009 |
| Oct 14, 2009 | A | NOV SENT OUT | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... | 1 | Jan 17, 2010 |
| Oct 14, 2009 | A | NOV SENT OUT | § 27-2050 ADM CODE MAINTAIN ON THE PREMISES A COPY OF THE SPRINKLER TEST FOR THE CURRENT YEAR. AT PUBLIC HALL | — | Jan 17, 2010 |
| Oct 14, 2009 | B | NOV SENT OUT | D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEP... | — | Nov 18, 2009 |
| Oct 14, 2009 | A | NOV SENT OUT | D26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... | — | Jan 17, 2010 |