ECB violations
175 Remsen Street, Brooklyn • Block 00250 • Lot 0007
51 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 22, 2025 | 39145668K | RESOLVE | CLASS - 2 | REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. ADJUST BOTTOM LANDING HOISTWAY DOOR ACCESS HOLE. ELIMINATE ... | $1,562 | $0 | Aug 6, 2025 |
| Apr 22, 2025 | 39145667Z | RESOLVE | CLASS - 2 | REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. ADJUST BOTTOM LANDING HOISTWAY DOOR ACCESS HOLE. ELIMINATE ... | $1,562 | $0 | Aug 6, 2025 |
| Sep 16, 2024 | 39124932H | ACTIVE | CLASS - 3 | FEDERAL PLW-100 BOILER=BODY DRAIN PIPES MISSING AT SAFETY VALVES+DEFECTIVE SAIL SWITCH AT FRESH AIR FAN+BOTH BUILDING... | $500 | $0 | Nov 20, 2024 |
| Jan 16, 2024 | 37026790J | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES RE... | $625 | $0 | May 1, 2024 |
| Dec 26, 2023 | 39102214X | ACTIVE | CLASS - 1 | CLASS 1 ITEM: 2 FUSES IN DISPATCH CONTROLLER HAVE THE INCORRECT FUSE RATING. CLASS 2 ITEMS:ELEVATOR MAIN GEAR CASE IS... | $1,250 | $0 | Apr 19, 2024 |
| Dec 26, 2023 | 39102216J | RESOLVE | CLASS - 1 | CLASS 1 ITEM: 2 FUSES IN DISPATCH CONTROLLER HAVE THE INCORRECT FUSE RATING. ELEVATOR MAIN GEAR CASE IS LEAKING OIL A... | $1,250 | $0 | Apr 19, 2024 |
| Dec 26, 2023 | 39102215H | RESOLVE | CLASS - 1 | CLASS 1 ITEM: 2 FUSES IN DISPATCH CONTROLLER HAVE THE INCORRECT FUSE RATING. CLASS 2 ITEMS: ELEVATOR MAIN GEAR CASE I... | $1,250 | $0 | Apr 19, 2024 |
| Dec 11, 2023 | 35674313J | ACTIVE | CLASS - 2 | REMOVAL OF PUBLIC PROTECTION FROM UNSAFE FACADE WITHOUT APPROVAL FROM THE DEPARTMENT. -AT TIME OF INSPECTION I OBSERV... | $1,250 | $0 | Apr 4, 2025 |
| Apr 16, 2023 | 35670241L | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.NOTE:VIOLATION#35670855X STATES FAILURE TO PROVIDE SAFETY MEASURES WHERE ... | $0 | $0 | Dec 11, 2023 |
| Mar 16, 2023 | 35670855X | RESOLVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SIDEWALK SHED FENCE ECT WHERE REQUIRE TO PROTECT AND SEC... | $0 | $0 | Oct 6, 2023 |
| Nov 10, 2020 | 35509275Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTE:AT TIME OFMY INSPECTION OF A 12 STORYS BLDG 1 OBSERVED BY... | $2,430 | $0 | Apr 21, 2021 |
| Mar 2, 2020 | 39018667R | RESOLVE | CLASS - 1 | CLASS 1 CEASE USE ITEM..... GAP OBSERVED BETWEEN BRAKE DRUM AND PAD. PERFORM BRAKE MAINTENANCE AND PROVIDE DATE ON TA... | $1,250 | $0 | Jul 22, 2020 |
| Nov 15, 2019 | 37016850N | RESOLVE | CLASS - 2 | BC27-929.1/A.C 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF FULL SYTEM OF AUTOMATIC SPRINKLER AND FILE A FINAL SP... | $1,250 | $0 | Dec 3, 2020 |
| Oct 24, 2019 | 39011741Y | RESOLVE | CLASS - 2 | REPAIR AND RESTORE DEVICE TO SERVICE. | $0 | $0 | Feb 26, 2020 |
| Mar 9, 2018 | 38261749Y | RESOLVE | CLASS - 2 | 3M7,15M7,92K2,56Y2,56Y10,39X2. 3M7-MISISNG CITY ID TAG IN CAB AND CAPACITY PLATE; 15M7-PROVIDE LOCATION FOR CERTIFICA... | $0 | $0 | Apr 30, 2018 |
| Oct 27, 2017 | 35285362R | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MET CODE SPEC.3307.6.5.3 SIDEWALK SHED SHALL BE MAINTAINED AND USED BY GC AND WHERE TH... | $2,400 | $0 | May 2, 2018 |
| Jun 27, 2016 | 38243956H | RESOLVE | CLASS - 1 | 05N10 REPAIR BYPASSED DOOR ZONE LOCK AND RENDER OPERATIVE. | $1,000 | $0 | Aug 31, 2016 |
| Jan 12, 2016 | 38240629R | RESOLVE | CLASS - 2 | 59U15,70O02. 59U15-BRAKE MAINTENANCE TAG; 70O02-PIT IS DIRTY. | $250 | $0 | Feb 29, 2016 |
| Jan 12, 2016 | 38240630Y | RESOLVE | CLASS - 2 | 50U15,70O02,05X10. 59U15-BRAKE MAINTENANCE TAG; 70O02-PIT IS DIRTY; 05X10-DOOR ZONE RESTRICTOR IS NOT WORKING. | $500 | $0 | Feb 29, 2016 |
| Jan 12, 2016 | 38240631X | RESOLVE | CLASS - 2 | 59U15,70O02. 59U15-BRAKE MAINTENANCE TAG; 70O02-PIT IS DIRTY. | $500 | $0 | Feb 29, 2016 |
| Jun 11, 2013 | 34990097M | RESOLVE | CLASS - 2 | PARTIAL *SWO* LICENSED RIGGER DESIGNATED AN UNQUALIFIED FOREMAN ON SITE.NOTED:1 WORKER DOING FACADE REPAIRS W/O LICEN... | $400 | $0 | Aug 19, 2013 |
| Jun 11, 2013 | 34990098Y | RESOLVE | CLASS - 2 | PARTIAL *SWO* FAIL NOTIFY DEPT PRIOR TO USE/INST OFF C-HOOKS.NOTE:LICENSED RIGGER CALLED IN NOTIFICATION FOR C-HOOKS,... | $400 | $0 | Aug 26, 2013 |
| Nov 29, 2011 | 38219430N | RESOLVE | CLASS - 2 | 52K11,44H02,56Y13,56O02,42O02,42G11,43L11,17H11,17D06,16B11,70O02,12X10-52K-LUBE OR REPLACE,44H-REGROOVE,56Y-SEAL LEA... | $250 | $0 | Jan 23, 2012 |
| Nov 29, 2011 | 38219428Y | RESOLVE | CLASS - 2 | 17M11,17O06,01B10,02B10,16B11,40B09,56Y13,56O02,56Q03,42G11,42N09,42O02,76M07,39O02,52M07,70O02-17MD-REPLACE/SECURE W... | $0 | $0 | Jan 23, 2012 |
| Nov 29, 2011 | 38219429X | RESOLVE | CLASS - 2 | 42G11,42N09,56Y13,42O02,56Q03,17M11,16B11,17D06,52O02,70O02,42G-UNREADABLE FUSES,42N-FMI FUSE,56Y-SEAL LEAKS,42O-CLEA... | $0 | $0 | Jan 23, 2012 |
| Jan 27, 2010 | 36011660N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT/ENGINEER REPORT CERTIFYING EXIT/DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURC... | $800 | $0 | Dec 27, 2010 |
| Nov 29, 2008 | 34739354Y | RESOLVE | CLASS - 1 | FAIL MAINTAIN BLDG IN COMPLIANT MANNER:LACK OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2;37-954 OBSERVE CELL B... | $1,000 | $0 | Nov 25, 2009 |
| Feb 10, 2005 | 38150768H | RESOLVE | Non-Hazardous | 84L10 84-10 CAR COMMUNICATIONS. | $0 | $0 | Mar 28, 2005 |
| Jan 29, 2004 | 38144316X | RESOLVE | Non-Hazardous | 17H11 17-H, LOBBY GIBS | $0 | $0 | Mar 15, 2004 |
| Jan 29, 2004 | 38144317H | RESOLVE | Non-Hazardous | 15M07/17M07/17H11/21H11 17-M,12FL,L, AND 11.17-H LOBBY,21-H LOCKER ROLLER, L,6,7,10 AND 11 | $0 | $0 | Mar 15, 2004 |
| Jan 29, 2004 | 38144318J | RESOLVE | Non-Hazardous | 15M07/17H11 17-H, LOBBY | $0 | $0 | Mar 15, 2004 |
| Nov 19, 2003 | 32043531H | RESOLVE | Hazardous | 4A,19B 36 4A HAZARDOUS 36 LOCHINARE HOT WATER BOILER MODEL RBN 045 | $800 | $0 | Jun 14, 2004 |
| Feb 7, 2003 | 38135714R | RESOLVE | Non-Hazardous | 70B07/ 17M07/ 16B01/ (17) MAIN REAR - (6) REAR (7FL) REAR (8FL) FRONT (9FL) FRONT (11FL) FRONT (12) FRONT (16) ADJUST... | $180 | $0 | Mar 24, 2003 |
| Feb 7, 2003 | 38135713P | RESOLVE | Non-Hazardous | 79X11/ 17M07/ (79) RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE (17) FRONT | $180 | $0 | Mar 24, 2003 |
| Feb 7, 2003 | 38135712N | RESOLVE | Non-Hazardous | 17M07/ (17) MAIN FL - BASEMENT - 2 - FL - - 7FL | $180 | $0 | Mar 24, 2003 |
| Mar 11, 1999 | 38084060J | RESOLVE | Non-Hazardous | 28L12,52H12. -28 REPLACE GUIDE ROLLER, -52 RELINE BRAKE SHOES, CALL FOR REINSPECTION BEFORE RETURN TO SERVICE | $2,500 | $0 | Jan 10, 2000 |
| Mar 11, 1999 | 38084061L | RESOLVE | Non-Hazardous | 52H12. -52 REPLACE BRAKE SHOES, CALL FOR REINSPECTION BEFORE RETURN TOSERVICE | $2,500 | $0 | Jan 10, 2000 |
| Feb 5, 1998 | 38067862R | RESOLVE | Non-Hazardous | 41B7-PROVIDE UP TRIP SWITCH. | $0 | $0 | Sep 28, 1998 |
| Feb 5, 1998 | 38067861P | RESOLVE | Non-Hazardous | 41B7-PROVIDE UP TRIP SWITCH ON GOV. | $0 | $0 | Sep 28, 1998 |
| Feb 3, 1998 | 38067852N | RESOLVE | Non-Hazardous | 35O,46O,50O,40O,41M,14M,41-M-07 PROVIDE UP TRIP SWITCH ON GOVERNOR | $0 | $0 | Mar 23, 1998 |
| Jun 4, 1996 | 34142662Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY POWER EXIT LIGHT ON FLOORS 8+7.FAILURE TO PROVIDE EMERGENCY POWER TO EXIT-DIRECTIONAL SI... | $800 | $0 | Nov 4, 1996 |
| Jun 3, 1994 | 38041762Y | RESOLVE | Non-Hazardous | 52H,74M, (74) NYC DESIGNATED ELEVATOR NO (AMEND RULE 208.10) | $0 | $0 | Jul 18, 1994 |
| Jun 3, 1994 | 38041763X | RESOLVE | Non-Hazardous | 52H,74M | $0 | $0 | Jul 18, 1994 |
| Oct 27, 1992 | 38028612M | RESOLVE | Non-Hazardous | 37G, | $0 | $0 | Dec 14, 1992 |
| Oct 27, 1992 | 38028611K | RESOLVE | Non-Hazardous | 02I,08V,21L, 21. BOBBY IND., LIGHTS. | $0 | $0 | Dec 14, 1992 |
| Oct 27, 1992 | 38028613Y | RESOLVE | Non-Hazardous | 37G,21L, 21. LOBBY DIR.INDIC. | $0 | $0 | Dec 14, 1992 |
| Mar 4, 1992 | 38022413M | RESOLVE | Non-Hazardous | 73#;57O;03O; 73. PERFORM FIVE YEAR TEST PROPERLY TAG DEVICE AND FILE ELEV. 3 FORM. 03. TOP OF CAR. | $75 | $0 | Apr 20, 1992 |
| Mar 4, 1992 | 38022412K | RESOLVE | Non-Hazardous | 73#;57O;030; 73. PERFORM 5 YEAR TEST AND PROPERLY TAG DEVICE AND FILE #3.FORM. 03. TOP OF CAR. | $75 | $0 | Apr 20, 1992 |
| Mar 14, 1991 | 34054659N | RESOLVE | Non-Hazardous | FLOOR NUMBERING SIGNS MISSING OR DEFECTIVE BASEMENT STAIRWAYS "B" AND "C" NOT NUMBERED OR NAMED AS SUCH. REMEDY:PROVI... | $500 | $0 | Jul 1, 1991 |
| Mar 14, 1991 | 34054660K | RESOLVE | Non-Hazardous | STAIR AND OR ELEVATOR SIGN MISSING AT BASEMENT LEVEL IN "C" STAIRS C STAIRWAY LETTER MISSING. REMEDY PROVIDE SIGN AS ... | $500 | $0 | Aug 19, 1991 |