| Mar 23, 2021 | 35540925R | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.NOTE:TIME OF INSPECTION OBSERVED 2 GUYS CUTTING WOOD THROUGH AS I LOOKED THROUGH WINDOW.I KNOCK... | $2,500 | $0 | Aug 4, 2021 |
| Oct 10, 2018 | 35355961J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT TIME OF INSPECTION REAR EXPOSURE OF 232 COURT ST, EXP3 OBSE... | $0 | $0 | Dec 31, 2018 |
| Oct 9, 2009 | 34811302X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: AT 3RD FLR 2 ROOMS 1 AT FRONT & 1 AT REAR SIDE MISSING P... | $250 | $0 | Nov 30, 2009 |
| Sep 10, 2009 | 34796698Z | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION NOTE A 4'X8' SECTION OF PLYWOOD SHEATHING IS MISSING FROM CONST... | $0 | $0 | Nov 2, 2009 |
| Jun 25, 2009 | 34775819N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED: 1. STAGNANT WATER ACCUMULATED ON THE ROOF OF 3 CAR GARAGE O... | $1,000 | $0 | Aug 17, 2009 |
| Jun 25, 2009 | 34775820K | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. EXPIRED PERMIT. NOTED: SIDEWALK SHHED ERECTED W/PERMIT #3101606335H, HAS EXPIRED ON 12.29.08. REME... | $0 | $0 | Aug 17, 2009 |
| Apr 24, 2009 | 34753237X | RESOLVE | CLASS - 2 | EXPIRED SIDEWALK SHED PERMIT. UPON INSP NOTED: THERE ARE SIDEWALK SHEDS IN PLACE AND PERMIT #310160633 HAS BEEN EXP O... | $4,000 | $0 | Jun 15, 2009 |
| Jun 23, 2008 | 34652455L | RESOLVE | Hazardous | FAILURE TO OBTAIN A PERMIT FOR TEMPORARY CONSTRUCTION FOR SIDEWALK SHED NOTED CREATED SIDEWALK SHED ON BALTIC ST AND ... | $200 | $0 | Aug 21, 2008 |
| Jun 3, 2008 | 34652008J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL DEFECTS NOTED BROKEN AND DEFECTIVE LOOSE BRICK WALL ABOVE GARAGE WITH LEANING ... | $800 | $0 | Jul 21, 2008 |
| Jun 3, 2008 | 34652009L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN INTERIOR BLDG HAZ DEFECTS NOTED 1ST FL FOUND WITH PARTIAL DEMO OF SUSPENDED CEILING LEAVING EXPOS... | $800 | $0 | Jul 21, 2008 |
| Mar 22, 2005 | 32047423Z | RESOLVE | Non-Hazardous | 48B 50A 50B 1994 FULTON N.B. 71278 50A HOLES IN CEILING ABOVE BOILER 50B SEAL FLUE PIPE TO CHIMNEY. | $180 | $0 | May 9, 2005 |
| Mar 22, 2005 | 32047424K | RESOLVE | Non-Hazardous | 50A 50B 50C HEATING BOILER. 50A INSTALL THE SAFETY VALVE IN A VERTICALPOSITION WITH THE DISCHARGE PIPED DOWN. 50B HOL... | $0 | $0 | May 9, 2005 |
| Oct 16, 2000 | 32021092H | RESOLVE | Non-Hazardous | 36/49/51 INSTALLED AND OPERATED BOILER W/O PERMITS AND W/O EQUIPMENT USE PERMIT BOILER SEALED DO NOT USE. | $400 | -$400 | Dec 4, 2000 |