| — | I | INFO NOV SENT OUT | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Apr 9, 2024 | A | NOV SENT OUT | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 13, 2024 |
| — | I | INFO NOV SENT OUT | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Oct 23, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF IRON FENCE ERECTED UNDER DROP LADDER AT FIRE ESCAPE... | — | Oct 31, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTELINE IN THE KITCHEN LOCATED AT APT 4F, 4th ... | 4F | Mar 8, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, ... | 4F | Feb 28, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 4F | Feb 28, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES ..STOVE IN THE KITCHEN LOCATED AT APT 4F, 4th ST... | 4F | Mar 8, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ..WOOD SINK BASE CABINET IN THE KITC... | 4F | Mar 8, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ...WOOD PANELING INSTALLED WITHIN 1 FOOT OF STOVE A... | 4F | Mar 8, 2017 |
| Feb 28, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ..SCALDING HOT WATER TEMP OF 136 DEGREES AT SINK IN... | 4F | Mar 8, 2017 |
| Feb 27, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, APARTMENT AT NORTH | 4F | Jun 2, 2017 |
| Feb 27, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS I... | 4F | Apr 3, 2017 |
| Feb 27, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, AP... | 4F | Apr 3, 2017 |
| Feb 27, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 4F | Apr 3, 2017 |
| Feb 24, 2017 | C | VIOLATION CLOSED | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 4F | Feb 23, 2017 |
| Feb 24, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE FIRE GUARD COVERAGE FOR 24 HOURS UNTIL FURTHER NOTICE BUILDING THROUGHOUT | — | Mar 4, 2017 |
| Feb 22, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ..FIRE DAMAGED FLOOR JOISTS OF APT A... | 2F | Mar 2, 2017 |
| Feb 22, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SKYLIGHT AT ROOF | — | Mar 29, 2017 |
| Feb 22, 2017 | B | VIOLATION CLOSED | § 185, 240 M/D LAW PROPERLY FIRE RETARD IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT THE CELLAR CE... | — | Mar 29, 2017 |
| Feb 22, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ..BOILER AT CELLAR | — | Mar 2, 2017 |
| Feb 22, 2017 | C | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Mar 2, 2017 |
| Feb 22, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ...STORAGE SHED PREVENTING FIRE ESCAPE DROP LADDER ... | — | Mar 2, 2017 |
| Feb 22, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS ..REST... | — | Mar 29, 2017 |
| Feb 22, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ..FIRE RETARDANT SHEETROCK AT CEILIN... | — | Mar 2, 2017 |
| Feb 22, 2017 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Mar 29, 2017 |
| — | I | VIOLATION CLOSED | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESU... | — | — |
| Jan 3, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT ALL LOWER AND UPPER SASH WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st A... | 4F | Apr 8, 2017 |
| Jan 3, 2017 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 4... | 4F | Feb 7, 2017 |
| Jan 3, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET DOOR UNDER SINK IN THE ... | 4F | Apr 8, 2017 |
| Jan 3, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE BA... | 4F | Feb 7, 2017 |
| Jan 3, 2017 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .... IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, 1... | 4F | Feb 7, 2017 |
| Nov 28, 2016 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, ... | 4F | Nov 24, 2016 |
| Nov 28, 2016 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Dec 6, 2016 |
| Nov 28, 2016 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM THE DOOR TO CELLAR LOCKED AT PUBLIC HALL, 1st STORY | — | Dec 6, 2016 |
| Nov 28, 2016 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4t... | 4F | Nov 24, 2016 |
| Nov 14, 2016 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES . AT PUBLIC HALL, 4th STORY | — | Dec 19, 2016 |
| Nov 14, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND SOUTH WALL. ... | — | Feb 17, 2017 |
| Nov 14, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROVIDE STANDARD WIRE GLASS AT SKYLIGHT OR APPROVED TYPE WIRE SCREENS ABOVE AND BELOW SKYLIGHT GLA... | — | Dec 19, 2016 |
| Nov 14, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING. AT PUBLIC HALL, 4th STORY | — | Dec 19, 2016 |
| Nov 14, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AND SOUTH WAL... | — | Dec 19, 2016 |
| Nov 10, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW. IN THE 2nd ROOM FROM... | 4F | Dec 15, 2016 |
| Nov 10, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE COUNTER TOP AT NORTH WALL . IN THE KITCHEN LOCATED AT APT... | 4F | Dec 15, 2016 |
| Nov 10, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | 4F | Feb 13, 2017 |
| Nov 10, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET DOOR AT NORTH WALL. IN THE KITCHEN LOCATED AT... | 4F | Dec 15, 2016 |
| Nov 10, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW. IN THE KITCHEN LOCAT... | 4F | Dec 15, 2016 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Nov 2, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 1st ... | — | Feb 5, 2017 |
| Nov 2, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AT PUBLIC HALL, 4th ... | — | Feb 5, 2017 |
| Nov 2, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING CEILING AT PUBLIC HAL... | — | Dec 7, 2016 |