ECB violations
279-289 Butler Street, Brooklyn • Block 00406 • Lot 0067
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 24, 2026 | 39181677K | RESOLVE | CLASS - 2 | EXCESSIVE OIL IN PIT. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. CONTACTOR STICKER MISSING FROM MAIN L... | $0 | $0 | Jun 3, 2026 |
| Nov 14, 2025 | 39167055P | RESOLVE | CLASS - 1 | CLASS 1: CAR OPERATING PANEL FLOOR BUTTONS C, 2, 4 INOPERATIVE, REPAIR. PISTON LEAKING OIL, REPAIR. CLASS 2: PIT LIGH... | $3,125 | $0 | Jan 28, 2026 |
| Sep 16, 2025 | 39160494P | ACTIVE | CLASS - 1 | CLASS 1 CEASE USE ITEM: CONTROLLER F7 FUSE BYPASSED, ELIMINATING REQUIRED OVERCURRENT PROTECTION IN ELEVATOR CONTROL ... | $1,250 | $0 | Nov 26, 2025 |
| Jul 9, 2025 | 39153211K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. CLASS 2 ITEMS: 1) PIT DIRTY (OIL AND DEBRIS), REMOVE OIL AND C... | $1,592 | $0 | Sep 24, 2025 |
| May 22, 2025 | 39148755M | ACTIVE | CLASS - 2 | 1) THERE IS OIL IN THE PIT. CLEAN THE PIT AND THE REPLACE THE OIL WITH CLEAN OIL. 2) PROVIDE FIRE BLOCKING FOR THE HO... | $655 | $0 | Aug 6, 2025 |
| Jan 17, 2025 | 39135823M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $625 | $0 | Apr 28, 2025 |
| Jan 17, 2025 | 39135824Y | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS AT ROOF LEVEL. POTENTIAL FIRE OR SMOKE HAZARD., REPAIR/RE... | $0 | $0 | Mar 26, 2025 |
| Nov 4, 2024 | 39129357N | RESOLVE | CLASS - 2 | EXCESSIVE OIL LEAKS IN PIT. REPLACE WORN GIBS WHERE NEEDED. REPLACE WORN GIBS WHERE NEEDED. TOP OF CAR LIGHT INOPERAT... | $0 | $0 | Jan 15, 2025 |
| Dec 29, 2023 | 39102434H | RESOLVE | CLASS - 1 | CEASE USE ITEMS: 1)NO AUDIBLE ALARM/NON WORKING PHONE COMBINAATION. 2) EXCESSIVE OIL LEAKS CAUSING CAR TO DRIFT WITH ... | $1,250 | $0 | Apr 8, 2024 |
| Nov 14, 2023 | 39099274N | RESOLVE | CLASS - 2 | MAINTENANCE LOG NOT UP TO DATE (ONLY 1 ENTRY IN SEPTEMBER), PERFORM ROUTINE MAINTENANCE AND UPDATE THE MAINTENANCE LO... | $625 | $0 | Apr 8, 2024 |
| Nov 13, 2023 | 39099210Y | RESOLVE | CLASS - 2 | HOLES & ILLEGAL PLASTIC ACCESS PANALS FOUND THROUGHOUT THE BUILDINGS AND MECHANICAL ROOMS., REPAIR AND/OR REPLACE | $655 | $0 | Jun 10, 2024 |
| Mar 1, 2023 | 39080583R | RESOLVE | CLASS - 1 | I OBSERVED IN THE CORRIDORS THROUGHOUT THE BUILDING THE REMOVAL OF THE EXISTING EMERGENCY LIGHTS AND THE INSTALLATION... | $800 | $0 | Oct 20, 2023 |
| Mar 1, 2023 | 39080585K | RESOLVE | CLASS - 1 | I OBSERVED IN THE BASEMENT WATER METER AREA THE IMPROPER INSTALLATION OF THE WATER METER JUMPER, THE JUMPER IS INSTAL... | $1,250 | $0 | Oct 20, 2023 |
| Mar 1, 2023 | 39080586M | RESOLVE | CLASS - 2 | I OBSERVED IN THE ELEVATOR MACHINE ROOM THE MAIN DISCONNECT WITH IMPROPER FUSES AS PER EC 310.16 #2 AWG THHN HAS A MA... | $1,200 | $0 | Oct 20, 2023 |
| Mar 1, 2023 | 39080567R | RESOLVE | CLASS - 2 | OBSERVED NO VENTILATION IN THE GAS METER ROOM. THE ONLY VENTILATION WAS FROM AN ADJOINING ROOM. AS PER E 4 OF THE FUE... | $0 | $0 | May 10, 2023 |
| Mar 1, 2023 | 39080587Y | RESOLVE | CLASS - 2 | I OBSERVED IN THE BASEMENT ELECTRICAL AND ATS ROOMS THE STORAGE OF EQUIPMENT AND MATERIALS. THE SHALL BE NO STORAGE P... | $0 | $0 | May 10, 2023 |
| Mar 1, 2023 | 39080594M | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, OBSERVED: -EMERGENCY DOOR WILL NOT OPEN LOCATE AT ROOF LEVEL (STAIRCASE A) 6TH FLOOR., REPAIR/... | $0 | $0 | May 10, 2023 |
| Mar 1, 2023 | 39080593K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, GAINED ACCESS THROUGH SITE MAINTENANCE MANAGER. OBSERVED: -LEAK/WATER PENETRATION LOCATED AT R... | $0 | $0 | May 10, 2023 |
| Mar 1, 2023 | 39080595Y | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, OBSERVED: -CRACKS LOCATED ON ROOF LEVEL, ON THE EXTERIOR FACADE OF BULKHEAD AND MECHANICAL ROO... | $0 | $0 | May 10, 2023 |
| Mar 1, 2023 | 39080584Z | RESOLVE | CLASS - 1 | I OBSERVED IN THE ROOFTOP MECHANICAL ROOM THE UNPERMITTED USE OF FLEXIBLE CORDS AS PERMANENT WIRING TO THE WATER HEAT... | $1,600 | $0 | Oct 20, 2023 |
| Feb 14, 2023 | 39079677J | RESOLVE | CLASS - 2 | IN CAR COMMUNICATION INOPERATIVE, REPAIR. CALL BUTTONS ON THE CAR STATION MISSING BRAILLE TAGS AND FLOOR NUMBERS, PRO... | $625 | $0 | Jun 28, 2023 |
| Mar 7, 2022 | 35644360P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.I OBSERVED ON THE ROOF LEVEL EXCESSIVE STORAGE IN THE WATER HEA... | $625 | $0 | Aug 24, 2022 |
| Mar 7, 2022 | 35644361R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.I OBSERVED NO FRESH AIR VENT IN THE GAS METER ROOM.AS PER E4 OF... | $625 | $0 | Aug 24, 2022 |
| Oct 28, 2021 | 39050227N | RESOLVE | CLASS - 2 | CAR STATION LOBBY BUTTON MISSING. BRAILLE MISSING IN THE CAR STATION. IN CAR PHONE OR INTERCOM NOT WORKING. APPLICATI... | $310 | $0 | Mar 2, 2022 |
| Feb 24, 2020 | 35473151P | RESOLVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSSITABLE ELECTRICAL EQUIPMENT,APPERATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.I OBSERVED ... | $800 | $0 | Jan 4, 2021 |