| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 31, 2026 | 39552461L | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION FOR PARTIAL SWS REMOVAL I OBSERVED WORK CONTRARY TO SITE SAFETY PLAN-AT EXP#3/#4 ADJ PRO... | $0 | $0 | Jun 10, 2026 |
| Feb 1, 2026 | 39549761X | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF A 15 STORY NB (APPROXIMATELY 26045 SQUARE FEET) SITE CLOSED AND THERE WERE NO CONSTRUCTION A... | $2,500 | $0 | Apr 8, 2026 |
| Dec 22, 2025 | 39548408K | RESOLVE | CLASS - 1 | AT 12:50PM OBSERVED WORKERS WORKING ON SUPPORTED SCAFFOLD AGAINST THE COMMISSIONERS ORDER TO STOP ALL USE OF THE SUPP... | $10,000 | $0 | Apr 10, 2026 |
| Dec 22, 2025 | 39548410J | RESOLVE | CLASS - 1 | BC 3310.8.4 SITE SAFETY MANAGER MARY E LAGANA LICENSE #: 002602 FAIL TO NOTIFY THE DEPARTMENT OF ONGOING CONSTRUCTION... | $5,000 | $0 | Apr 10, 2026 |
| Dec 21, 2025 | 39548314J | RESOLVE | CLASS - 2 | BC 3303.3 TIME OF MY INSPECTION OF A 15 STORY NEW BUILDING, BUILDING APPROXIMATELY 223886 SQ. FEET. SITE CLOSED AND T... | $2,500 | $0 | Apr 10, 2026 |
| Dec 21, 2025 | 39548317P | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED SUPPORTED PIPE SCAFFOLD BUILT AT EXPOSURE 1 & 2 WITH THE LAYOUT OF THE SCAFFOLD D... | $0 | $0 | Apr 10, 2026 |
| Oct 4, 2025 | 39545626P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, DELIVERY IN PROCESS WITH LIFT OBSTRUCTING PEDESTRIAN SIDEWALK. FLAGPERSON ON SITE FAILED TO PR... | $2,500 | $0 | Dec 10, 2025 |
| Aug 16, 2025 | 39543747M | RESOLVE | CLASS - 1 | AT TIME OF MY INSPECTION ACTIVE SITE OBSERVED WORK IN PROCESS UPON REQUEST NO SITE SAFETY MANAGER WERE PRESENT ON SIT... | $10,000 | $0 | Oct 22, 2025 |
| Jul 19, 2025 | 39542573R | RESOLVE | CLASS - 2 | BC3303.3 WATCHPERSON15 STORY NEW BUILDING, BUILDING APPROXIMATELY 32500 SQUARE FEET. SITE CLOSED AND THERE WERE NO CO... | $2,530 | $0 | Nov 24, 2025 |
| Jul 5, 2025 | 39542009X | RESOLVE | CLASS - 2 | INACTIVE JOBSITE, WITH A BUILDING FOOTPRINT (SQ. FT.) 223886, WALK JOBSITE PERIMETERS, KNOCK & CALLED OUT, I OBSERVED... | $2,500 | $0 | Sep 10, 2025 |
| Jun 2, 2025 | 39149592L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION FOR CD00004932, CN00083924, PERSON ACTING ASLIFT DIRECTOR, MASTER RIGGER OR MASTER RIGGER F... | $0 | $0 | Aug 13, 2025 |
| Jun 2, 2025 | 39149591J | ACTIVE | CLASS - 2 | AT THE TIME OF THE INSPECTION FOR CD00004932, CN00083924, PERSON ACTING AS LIFT DIRECTOR, MASTER RIGGER OR MASTER RIG... | $6,250 | $6,250 | Aug 13, 2025 |
| May 24, 2025 | 39540623R | RESOLVE | CLASS - 2 | NOTE: AT THE TIME OF INSPECTION AT APPROXIMATELY 7:10 AM, I OBSERVED CONSTRUCTION WORK IN PROGRESS CONTRARY TO THE ST... | $625 | $0 | Aug 6, 2025 |
| May 24, 2025 | 39540624Z | RESOLVE | CLASS - 1 | NOTE: AT TIME OF INSPECTION OF A 13-STORY NEW BUILDING ACTIVE CONSTRUCTION WORK IN PROGRESS, UPON REQUEST, NO SITE SA... | $10,000 | $0 | Aug 6, 2025 |
| Apr 8, 2025 | 39144208P | RESOLVE | CLASS - 2 | FOUNDATION WALLS OUTBOARD INSULATION WERE INSTALLED WITH THICKNESS 2" R-VALUE-10 CONTRARY TO THICKNESS 2 1/4" R-VALUE... | $0 | $0 | Jun 18, 2025 |
| Apr 3, 2025 | 39538735Z | RESOLVE | CLASS - 2 | OBSERVE SUPPORT SCAFFOLD AT EXP1 INSTALLED CONTRARY TO APPROVE DOCUMENTS. EQ -010.02 SHOW A 2FT WIDE FRAME TYPE ON TO... | $0 | $0 | Jun 11, 2025 |
| Mar 31, 2025 | 39538537H | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION OBSERVED ARTICULATING BOOM CRANE INSTALLED/PARKED/IN USE AT VEHICULAR LANE LIFTING MATERIAL... | $0 | $0 | Jun 4, 2025 |
| Mar 7, 2025 | 39537763L | RESOLVE | CLASS - 1 | BC3301.2 - FAILURE TO INSTITUTE SAFETY MEASURES. WORKER WAS INJURED BY A FALL THROUGH UNPROTECTED OPENING IN THE FLOO... | $12,500 | $12,500 | Apr 16, 2026 |
| Dec 20, 2024 | 39535283N | RESOLVE | CLASS - 2 | 3307.4.7 WORK OR STORAGE ZONES, FAILURE TO PROVIDE CHAIN LINK FENCING ON BARRIERS AND SOLID 4 FEET PANEL WITH CHICKEN... | $0 | $0 | Aug 15, 2025 |
| Dec 20, 2024 | 39535275N | RESOLVE | CLASS - 2 | STANDING WATER ACCUMULATION . AT THE TIME OF MY INSPECTION OF A ACTIVE JOB SITE WITH APPROXIMATELY 60 WORKERS OF VARI... | $0 | $0 | Aug 15, 2025 |
| Dec 20, 2024 | 39535274L | RESOLVE | CLASS - 2 | BC 3308.6 MISSING HORIZONTAL NETTING. AT THE TIME OF MY INSPECTION OF A 13 STORY NEW BUILDING CURRENTLY AT 7 FLOOR LE... | $2,500 | $0 | Aug 15, 2025 |
| Dec 20, 2024 | 39535276P | RESOLVE | CLASS - 2 | BC 3313.1 FAILURE TO COMPLY WITH FIRE CODE. AT TIME OF MY INSPECTION I OBSERVED OXYGEN AND ACETYLENE TANKS OF GASES O... | $2,500 | $0 | Aug 15, 2025 |
| Oct 24, 2024 | 35686534L | RESOLVE | CLASS - 1 | NO SITE-SPECIFIC FORMWORK DESIGN DRAWINGS PRESENT PER 3301.17. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTI... | $2,500 | $0 | Jan 8, 2025 |
| Mar 2, 2024 | 39107522K | RESOLVE | CLASS - 1 | WHILE DIGGING A TEST PIT, EXCAVATOR HIT ADJACENT PROPERTY AT 233 NEVINS ST DAMAGING PARAPET AND CORNER OF ONE STORY S... | $10,000 | $0 | Jul 26, 2024 |
| Feb 23, 2023 | 39513454L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED INSTALLED JERSEY BARRIERS ON EXPOSURE 1 AND 4. THE PEDESTRIAN WALKWAY WAS NOT MAI... | $2,400 | $2,400 | May 3, 2023 |
| Feb 23, 2023 | 39513456P | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED INSTALLED CONSTRUCTION FENCE WITH EXPIRED PERMIT. FENCE PERMIT UNDER B00661581 WA... | $3,125 | $3,125 | Oct 23, 2023 |
| Feb 23, 2023 | 39513453J | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED INSTALLED CONSTRUCTION FENCE WITH EXPIRED PERMIT. FENCE PERMIT UNDER B00661629 WA... | $0 | $0 | May 3, 2023 |
| Feb 23, 2023 | 39513458Z | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED INSTALLED JERSEY BARRIER AND SIDEWALK CLOSURE ON EXPOSURE 1 AND 4. UPON REQUEST, ... | $1,250 | $1,250 | Dec 18, 2023 |
| Feb 23, 2023 | 39513457R | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, PROJECT PANEL WAS NOT POSTED ON THE CONSTRUCTION FENCE. G.C FAILED TO COMPLY WITH BC3301.9. | $3,125 | $3,125 | Oct 23, 2023 |
| Jan 9, 2023 | 39511426P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED YODOCK BARRIERS AT STREET LEVEL AT EXPOSURES 1 / 2 TO PROTECT THE SAFETY OF PEDESTRIAN... | $0 | $0 | May 3, 2023 |
| Jan 9, 2023 | 39511425N | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION , OBSERVED BARRIOS ON ROADWAY PROVIDED TO PROTECT PEDESTRIANS WAS NOT MAINTAINED AS REQUIRED . ... | $1,250 | $1,250 | May 3, 2023 |