100-108 Wolcott Street, Brooklyn
Brooklyn • Block 00565 • Lot 0025 • Zip: 11231
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Downtown Brooklyn 24 min 14 walking, 10 riding
- Fulton Street 32 min 14 walking, 18 riding
- Union Square 41 min 14 walking, 27 riding
- Penn Station 44 min 14 walking, 30 riding
- Times Square 45 min 14 walking, 31 riding
- Grand Central 47 min 14 walking, 33 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Railroad
Ferry
Bus
Citi Bike
Places nearby
Red Hook Tavern
Red Hook Tavern offers a cozy and inviting atmosphere with a menu focused on classic American comfort food. Located i...
Hometown Bar-B-Que
Hometown Bar-B-Que is a popular spot in Brooklyn known for its mouthwatering smoked meats and BBQ dishes. The rustic ...
San Pedro
No description yet
Lundy Bros.
No description yet
Cafe Kestrel
No description yet
Steve's Authentic Key Lime Pies
No description yet
Defonte's
Defonte's is a beloved Brooklyn institution known for its mouthwatering Italian sandwiches. With a cozy and welcoming...
The Good Fork Pub
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
DOB violation Apr 2, 2026
C-CONSTRUCTION OTHER OPTIONAL
EMERGENCY WORK ORDER-S/W VAULT APPROX 5'DEEP ALONG EXP1 IN A STATE OF SEVERE DISREPAIR W/NON-ENGINEERED SHORING,HEAVI...
-
DOB violation Apr 2, 2026
C-CONSTRUCTION OTHER OPTIONAL
FTM BLDG IN A SAFE CONDITION-BLDG IS IN A STATE OF DSREPAIR W/SEVERELY TO MODERATE CORRODED CELLAR COLUMNS,DETERIORAT...
-
CLASS - 1
AT TIME OF INSPECTION OBSERVED AT CELLAR LEVEL,TEMPORARY STEEL SHORING (COLUMNS AND I BEAM) HAVE BEEN INSTALLED AT SI...
-
CLASS - 1
OBSERVED AT CELLAR LEVEL CAST IRON SUPPORT COLUMN HAS BECOME DISLODGED AND UNSTABLE WITH CRACKED FLOOR JOIST DIRECTLY...
-
DOB violation Apr 1, 2026
C-CONSTRUCTION OTHER OPTIONAL
ENGINEERS REPORT REQUIRED DUE TO UNSTABLE SUPPORT COLUMN, CRACKED FLOOR/CELING JOIST AND DISPLACED/UNSAFE SIDEWALK VA...
2025
-
DOB violation Nov 14, 2025
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
2024
-
DOB violation Sep 23, 2024
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
2022
-
CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ON SITE(SIDEWALK SHED)EXPIRED PERMIT.OBSERVED SIDEWALK SHED IN PLACE WITH EXPIRED PE...
-
CLASS - 2
TEMP CONST EQUIPMENT ONSITE W/EXPIRED PERMIT-SWS@EXP1 W/EXPIRED PERMIT.NOTE:ATO MY INSP OF 4STYB,OBSERVED ERECTED SWS...
2021
-
HPD violation Apr 13, 2021
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
-
CLASS - 2
FAILURE TO MAINTAIN BLDG WALLS OR APPURTENACES. AT THE TIME OF INSPECTION & OBSERVED @ EXP#4 REAR OF PREMISE STRESS-L...
-
DOB violation Mar 3, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2020
-
CLASS - 1
ON EXP 4 OF BUILDING SECTION OF WALL IS ON 2ND FLOOR IS BUCKLING AND PULLING AWAY FROM BUILDING ON CORNER WHERE YOU E...
2018
-
HPD violation Oct 22, 2018
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2016
-
HPD violation Nov 15, 2016
Class I
SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CO...
2013
-
HPD violation Mar 14, 2013
Class C
SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BUILDING ENTRANCE DOOR LOCK , 1st STORY
-
HPD violation Feb 25, 2013
Class B
SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW SASH IN THE ENTIRE APARTMENT LOCATED AT...
-
HPD violation Feb 25, 2013
Class B
SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records