ECB violations
181 26 Street, Brooklyn • Block 00654 • Lot 0034
76 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 27, 2026 | 39197824H | ACTIVE | CLASS - 2 | ATOI OBSERVED IN BASEMENT LAUNDRY ROOM PVC PIPING USED FOR WASTE.ALSO IN ADJASENT ROOM SLOP SINK HAVING WASTE LINE WI... | $1,250 | $1,250 | Oct 7, 2026 |
| Jul 27, 2026 | 39197687K | ACTIVE | CLASS - 1 | CLASS 1 C/U: DOOR LOCK MONITORING FOR CAR REAR DOOR INOPERATIVE AS PER ASME A17.1 2.26.5 AND 8.6.4.7, FAILING TO ENSU... | $1,250 | $1,250 | Oct 7, 2026 |
| Jul 27, 2026 | 39197688M | ACTIVE | CLASS - 2 | CLASS 2: 1. EMERGENCY PHONE INOPERATIVE AS PER ASME A17.1 2.27.1, FAILING TO PROVIDE REQUIRED EMERGENCY COMMUNICATION... | $625 | $625 | Oct 7, 2026 |
| Jul 27, 2026 | 39197825J | ACTIVE | CLASS - 1 | ATOI OBSERVED IN MECHANICAL ROOM WATER HEATERS INSTALLED WITHOUT ADEQUATE SPACE FOR REPAIR OR REPLACEMENT. EXHAUST PI... | $2,500 | $2,500 | Oct 7, 2026 |
| Apr 3, 2025 | 39143744Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED IMPROPER VENTILATION FOR TANKLESS WATER HEATERS. LOCA... | $0 | $0 | Jun 11, 2025 |
| Nov 8, 2024 | 39129798Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REM... | $0 | $0 | Jan 15, 2025 |
| Nov 22, 2023 | 39099930M | RESOLVE | CLASS - 2 | EMERGENCY LIGHTS DO NOT WORK LOCATED THROUGHOUT BUILDING, REPAIR AND/OR REPLACE LIGHTING | $0 | $0 | Feb 7, 2024 |
| Nov 22, 2023 | 39099931Y | RESOLVE | CLASS - 2 | ADMINISTRATION DESK BLOCKING EGRESS/EMERGENCY EXIT LOCATED GROUND LEVEL.; 28-301.1, COMPLY WITH CODE | $1,250 | $0 | Dec 2, 2024 |
| Nov 22, 2023 | 39099927L | RESOLVE | CLASS - 2 | OBSERVED IN THE SUB-CELLAR EXCESSIVE STORAGE IN THE MECHANICAL ROOM. THE MECHANICAL ROOM HOUSES 2 GAS FIRED INSTANT H... | $0 | $0 | Feb 7, 2024 |
| Nov 22, 2023 | 39099928N | RESOLVE | CLASS - 2 | ILLEGAL PLASTIC EXCESS PANELS INSTALLED ON CEILINGS LOCATED THROUGHOUT THE BUILDING., PROVIDE/MAINTAIN FIRE STOPPING | $0 | $0 | Feb 7, 2024 |
| Nov 22, 2023 | 39099929P | RESOLVE | CLASS - 2 | EMERGENCY EXIT DOORS DO NOT CLOSE LOCATED AT ROOF LEVEL AND GROUND LEVEL EXPOSURE 2., REPAIR/REPLACE DOOR | $0 | $0 | Feb 7, 2024 |
| Oct 13, 2023 | 39097022H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP... | $625 | $0 | Dec 20, 2023 |
| Oct 3, 2022 | 39071232K | RESOLVE | CLASS - 2 | EXPIRED BRAKE MAINT TAG. EXPIRED CAT ONE TAG. KINK IN GOV ROPE. SHORTEN GOV ROPE. | $0 | $0 | Feb 8, 2023 |
| Oct 3, 2022 | 39071233M | RESOLVE | CLASS - 2 | EXPIRED BRAKE MAINT TAG. EXPIRED CAT ONE TAG. KINK IN GOV ROPE. ADJUST SC LEVEL HOISTWAY DOOR ACCESS HOLE. SHORTEN HO... | $0 | $0 | Feb 8, 2023 |
| Apr 2, 2022 | 35636959L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN SWS AS PER CODE.AT TIME OF RESPONDING TO COMP#3838091 OBSERVED FOLLOWING MISSING PROJECT INFORMAT... | $312 | $0 | Sep 14, 2022 |
| Dec 15, 2021 | 39052873R | RESOLVE | CLASS - 2 | I OBSERVED ON FLOORS 3,6,9 THE INSTALLATION OF HOT WATER HEATERS WITHOUT A REMOTE SHUT-DOWN SWITCH AS REQUIRED IN MC ... | $1,250 | $0 | Apr 20, 2022 |
| Dec 15, 2021 | 39052872P | RESOLVE | CLASS - 2 | I OBSERVED IN THE BASEMENT ATS ROOM THE INSTALLATION OF WOOD SHELVING, TOOLS, MATERIALS, AND AN OFFICE DESK. NO STORA... | $0 | $0 | Apr 20, 2022 |
| Sep 28, 2021 | 35562698N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V35582198P ISSUED8/10/21 &TO FILE C/C PURSUANT TO28-201... | $1,280 | $0 | Feb 9, 2022 |
| Aug 10, 2021 | 35582198P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. I OBSERVED IN CELLAR/BASEMENT RESIDENTIAL GAS FLEX ON COMMERCI... | $1,250 | $0 | Dec 22, 2021 |
| Aug 10, 2021 | 39045731X | RESOLVE | CLASS - 2 | AT 7TH FL STAIR B, 6TH FL FRONT ELECTRICAL RM, 5THFL FRONT ELECTRICAL RM, 4THFL STAIR B, FIRST CORRIDOR FRONT RM 104,... | $0 | $0 | Dec 15, 2021 |
| Aug 10, 2021 | 39045730Y | RESOLVE | CLASS - 2 | AT 5TH FL STAIR B DOOR, 4TH FL STAIR A&B DOOR, 3TH FL STAIR A&B DOOR, 2ND FL STAIR A DOOR, FIRST FL STAIR B DOOR DO N... | $655 | $0 | Dec 15, 2021 |
| May 18, 2018 | 37010725R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPUR... | $1,250 | $0 | Nov 5, 2018 |
| May 3, 2018 | 38262189J | RESOLVE | CLASS - 2 | 05J01,60B07,59H10,59BB15,67B07. 05J01-RETRACTING VAIN IS STRIKING ROLLERS; 60B07-MOTOR ROOM LIGHTS ARE NOT WORKING; 5... | $625 | $0 | Nov 7, 2018 |
| Jan 30, 2018 | 38261128L | RESOLVE | CLASS - 1 | 42X10,57R11,42M07,68B07,40R07,13X10,01B10,02B10,37X10,53I10,75T15,69B11-*CEASE USE ITEM 42X)INOPERATIVE DOOR POSITION... | $1,000 | $0 | Jul 25, 2018 |
| Sep 1, 2010 | 34769586K | RESOLVE | CLASS - 2 | SEC. 1103.1. ROOMS BEING STORED W/FURITURE ETC. BEDDING. UPON INSP FURNISHING DELIVERED & BEING DELIVERED TO SITE, CH... | $0 | $0 | Oct 25, 2010 |
| Sep 1, 2010 | 34769583P | RESOLVE | CLASS - 2 | NO DOT PERMIT POSTED. UPON INSP. ON 26 ST SIDE OF SITE ENTIRE SIDEWALKCLOSED AND IS UNDER CONST (PREPARING FOR NEW SI... | $500 | $0 | Jan 24, 2011 |
| Sep 1, 2010 | 34769585Z | RESOLVE | CLASS - 2 | NO DOT PERMIT POSTED. UPON INSP SIDEWALK CLOSED TO PEDESTRIAN TRAFFIC ON 26 ST SIDE OF SITE. 5' WALKWAY IN ROADWAY NO... | $500 | $0 | Jan 24, 2011 |
| Jul 29, 2010 | 34857987L | RESOLVE | CLASS - 1 | 3314.8 EXCEPT FOR SCAFFOLD PLATFORMS 6' OR LESS ABOVE THE GROUND THE OPEN SIDES & ENDS OF EVERY SCAFFOLD PLATFORM SHA... | $1,600 | $0 | Sep 20, 2010 |
| Jul 29, 2010 | 34857986J | RESOLVE | CLASS - 1 | 3314.9 SUPPORTED SCAFFOLD DOES NOT MEET CODE SPECIFICATIONS NOTED: UPON INSPECTION THE FOLLOWING WER EFOUND SCAFFOLD ... | $1,600 | $0 | Sep 20, 2010 |
| Apr 13, 2010 | 34844244H | RESOLVE | CLASS - 1 | SEC-BC3314.4.1-INSTALLATION SCAFFOLDS THAT REQUIRE A PERMIT OR DESIGN SHALL BE ERECTED & INSTALLED IN ACCORDANCE W/CO... | $1,600 | $0 | Jun 7, 2010 |
| Mar 31, 2010 | 34832506K | RESOLVE | CLASS - 2 | SIDEWALK SHED DOESN'T MEET BLDG CODE SPECIFICATIONS. NOTED: SHED AT EXP 1 IS MISSING HORIZONTAL BRACING AT APPROX 20'... | $2,400 | $0 | Jun 24, 2010 |
| Mar 31, 2010 | 34832505Z | RESOLVE | CLASS - 1 | SEC. 3314.9. SUPPORTED SCAFFOLD DOESN'T MEET BLDG CODE SPECIFICATIONS.NOTED: EQUIPMENT AT EXP 1,2 HAS INADEQUATE/UNST... | $0 | $0 | Jul 6, 2010 |
| Mar 31, 2010 | 34832507M | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUPPORTED SCAFFOLDS PERFORMED BY AN AUTHORIZED PERSON AT SITE. NOTED: SUPPORTED SCAF... | $2,400 | $0 | Jun 28, 2010 |
| Mar 31, 2010 | 34832508Y | RESOLVE | CLASS - 1 | FAILURE TO PERFORM A SAFE/PROPER INSPECTION OF SUPPORTED SCAFFOLDS. NOTED: AT APPROX 2 PM THERE ARE APPROX 4 MEN WORK... | $10,000 | $0 | Jun 28, 2010 |
| Feb 8, 2010 | 34827049H | RESOLVE | CLASS - 1 | FAIL TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS-UPON INSPECTION OBSERVED THE PANEL BOARDS IN TH... | $2,400 | $0 | Apr 5, 2010 |
| Feb 1, 2010 | 34827043R | RESOLVE | CLASS - 1 | BC3310.8.2(MISC)FAIL TO NOTIFY DOB ABOUT THE INCIDENT @ THE CONST SITE-UPON INSP NTED THE TEMP EXTERIOR ELEVATOR FOR ... | $400 | $0 | Mar 29, 2010 |
| Feb 1, 2010 | 34827042P | RESOLVE | CLASS - 1 | BC3303.12(MISC)FAIL TO PROVIDE ELEVATOR IN RESDINESS-UPON INSP NOTED THE ELECTRICAL CABLE OF THE TEMP PERSONAL & MATE... | $1,600 | $0 | Mar 29, 2010 |
| Jan 28, 2010 | 34827039Y | RESOLVE | CLASS - 1 | SEC. 3308.1. FAILURE TO MAINTAIN VERTICAL SAFETY NETTING - UPON INSPECTION NOTED: VERTICAL SAFETY NETTING NOT MAINTAI... | $1,600 | $0 | Jun 23, 2010 |
| Jan 28, 2010 | 34827040L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING - UPON INSPECTION THE FOLLOWING CONDITION OBSERVED: 1) LARGE QUANTITY OF CO... | $0 | $0 | Jul 1, 2010 |
| Jan 28, 2010 | 34827041N | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. UPON INSPECTION NOTED: LARGE QUANTI... | $0 | $0 | Jul 1, 2010 |
| Jan 4, 2010 | 34826875P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.OBSERVED THE ACCESS WAY TO THE HOIST IS IS FULL OF ICE ON GROUND LEVEL.THE ... | $0 | $0 | Mar 1, 2010 |
| Dec 14, 2009 | 34819412N | RESOLVE | CLASS - 2 | SEC. BC 310.3 FAILURE TO COMPLY WITH SITE SAFETY PLAN & PROGRAM. REMOVAL OF HORIZONTAL SAFETY NETTING W/O APPROVAL AS... | $0 | $0 | Feb 8, 2010 |
| Dec 14, 2009 | 34819410J | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE HORIZONTAL NETTING AT REQUIRED HEIGHT. 10TH FLR STRIPPING OPERATION IN PROGRESS ON CONCRETE STRUCT... | $0 | $0 | Feb 2, 2011 |
| Dec 14, 2009 | 34819399H | RESOLVE | CLASS - 2 | FAILURE TO POST D.O.T. PERMIT FOR OCCUPYING THE STREET. A CONTRACTORS OFFICE (PORTABLE UNIT) INSTALLED ON THE RIGHT L... | $0 | $0 | Feb 8, 2010 |
| Dec 14, 2009 | 34819411L | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM APPROVED SITE SAFETY PLAN. STRUCTURE IS UP TO 11TH FLR (ROOF). STRIPPING ON 10TH IN PROGRESS. H... | $0 | $0 | Feb 8, 2010 |
| Dec 3, 2009 | 34786223X | RESOLVE | CLASS - 2 | 1RCNY5-02 MISC VIOL: FAIL TO PROVIDE EMPLOYEE W.PHOTO ID. NOTED: AT THE TIME OF INSPECTION AT THE PLATE OF OCCURRENCE... | $400 | $0 | Jan 25, 2010 |
| Dec 3, 2009 | 34786224H | RESOLVE | CLASS - 2 | 1RCNY5-02 (A) MISC VIOL: FAIL TO PROVIDE EMPLOYEE W/PHOTO ID. NOTED: AT THE TIME OF INSPECTION AT THE PLACE OF OCCURR... | $0 | $0 | Jan 25, 2010 |
| Nov 25, 2009 | 34819392P | RESOLVE | CLASS - 1 | BC3304.3.1 FAILURE TO NOTIFY DOB PRIOR COMMENCEMENT OF EARTHWORK WITHIN THE PROPERTY LINE. OBSERVED EXCAVATION & FOUN... | $0 | $0 | Jan 26, 2011 |
| Nov 24, 2009 | 34819391N | RESOLVE | CLASS - 2 | BC3303.5.1(MISC)FAIL TO COMPLY W/NYC FIRE CODE TO REMOVE COMBUSTIBLE WASTE MATERIALS. OBSERVED A PILE OF WOODEN MATER... | $400 | $0 | Jan 11, 2010 |
| Oct 28, 2009 | 34786299M | RESOLVE | CLASS - 1 | SEC BC 3301.7 MISC VIOL: DESIGN REQUIRED- FAIL TO PROVIDE DESIGN FOR CANTILEVER WOODEN WALKWAY ON 6TH ST, NORTH SIDE ... | $1,600 | $0 | Dec 22, 2009 |