Maintenance code violations
773 4 Avenue, Brooklyn • Block 00658 • Lot 0005
334 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Apr 5, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILE IN THE 1st ROOM FRO... | 3R | May 10, 2018 |
| Apr 5, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 1st ROOM FROM NORT... | 3R | May 10, 2018 |
| Apr 5, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILE IN THE FOYER LOCATE... | 3R | May 10, 2018 |
| Apr 5, 2018 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR JAMB IN THE 1st ROOM FROM ... | 3R | May 10, 2018 |
| Apr 5, 2018 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jul 9, 2018 |
| Apr 5, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK AT APARTMENT ENTRANCE DOOR LOCATED AT APT 3R... | 3R | May 10, 2018 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN TH... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS LOCATED AT APT 3L, 3rd STORY | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING IN THE BATHROOM LO... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WALL OUTLET AT EAST AND SOUTH WALL IN THE KITCHEN LOCATED ... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 1 PANE GLASS AT LOWER WINDOE SASH IN THE KITCHEN LOCATED ... | 3L | Dec 8, 2016 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE OF SINK IN THE KITCHEN LOCATED AT APT 3L, ... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FRO... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 3L, 3rd STORY | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 3L, 3rd STORY | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE DOOR LOCK ASSEMBLY AT APARTMENT ENTRANCE LOCATED A... | 3L | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Jan 4, 2017 |
| Nov 30, 2016 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE ARTICLES AT PUBLIC HALL, 3rd STORY | — | Jan 4, 2017 |
| Nov 21, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 3R | Dec 26, 2016 |
| Nov 21, 2016 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 3R | Dec 19, 2016 |
| Nov 21, 2016 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC ... | — | Nov 29, 2016 |
| Nov 21, 2016 | B | VIOLATION CLOSED | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT LIGHT ... | — | Dec 26, 2016 |
| Nov 21, 2016 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3... | — | Feb 24, 2017 |
| Nov 21, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AT PUBLIC HAL... | — | Dec 26, 2016 |
| Nov 21, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 3R | Dec 26, 2016 |
| Nov 21, 2016 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 3rd... | — | Dec 26, 2016 |
| Nov 21, 2016 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT SHOWER STALL IN THE BATHROOM LOCATE... | 3R | Nov 29, 2016 |
| Nov 21, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES ON EAST WALL IN THE SH... | 3R | Dec 26, 2016 |
| Nov 21, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL COVER PLATE FOR OUTLET AT EAST WALL IN THE BATHROOM LOCATE... | 3R | Feb 24, 2017 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TOP AND BOTTOM DOOR SEALS. AT REFRIGERATOR. IN THE KITCHEN... | 3R | Sep 30, 2016 |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LOWER DOOR HANDLE AT REFRIGERATOR. IN THE KITCHEN LOCATED AT APT 3R, ... | 3R | Sep 30, 2016 |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATH... | 3R | Sep 30, 2016 |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 3R | Sep 30, 2016 |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 3R, 3rd STORY | 3R | Sep 30, 2016 |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 3R, 3rd STORY | 3R | Sep 30, 2016 |
| Aug 26, 2016 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY | 3R | Sep 30, 2016 |
| Mar 1, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ... | 3L | Jun 4, 2016 |
| Mar 1, 2016 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LEAKY HEAT RISER IN THE 1st ROOM FROM NORTH AT WEST LOCATE... | 3L | Mar 9, 2016 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Feb 18, 2014 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER AT A TEMPERATURE OF 140 DEGREES THA... | 2L | Feb 26, 2014 |
| Feb 18, 2014 | B | VIOLATION DISMISSED | SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2L, 2nd STOR... | 2L | Mar 25, 2014 |
| Feb 14, 2014 | C | VIOLATION CLOSED | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 2L | Feb 13, 2014 |
| May 28, 2013 | B | VIOLATION DISMISSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FR... | 5 | Jul 2, 2013 |
| May 28, 2013 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCONNECTED FREE STANDING RADIATOR AT PUBLIC... | — | Jun 5, 2013 |
| May 28, 2013 | B | VIOLATION DISMISSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | 5 | Jul 2, 2013 |
| May 28, 2013 | C | VIOLATION CLOSED | SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPEC... | 5 | Jun 25, 2013 |