ECB violations
275-277 37 Street, Brooklyn • Block 00695 • Lot 0046
34 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 7, 2025 | 39166295J | RESOLVE | CLASS - 2 | OBSERVED IN THE BUILDING USE OF FERNCO COUPLINGS AND CLOSED END TOILET SEATS. IN BASEMENT, PVC PIPING USED ON SINK AN... | $3,125 | $3,125 | Jan 14, 2027 |
| Mar 5, 2025 | 39140400R | RESOLVE | CLASS - 2 | FAILURE CERTIFY CORRECTION VIOLATION NUMBER 39134860R, FILE A CERTIFICATE OF CORRECTION | $0 | $0 | Jun 20, 2025 |
| Mar 5, 2025 | 39140402K | RESOLVE | CLASS - 2 | FAILURE TO CERTIFY CERTIFICATE OF CORRECTION FOR VIOLATION #39134861Z, FILE A CERTIFICATE OF CORRECTION | $0 | $0 | Jun 20, 2025 |
| Mar 5, 2025 | 39140401Z | RESOLVE | CLASS - 2 | FAILURE TO CERTIFY CERTIFICATE OF CORRECTIONS FOR VIOLATION #39134862K, FILE A CERTIFICATE OF CORRECTION | $1,250 | $1,250 | Jun 20, 2025 |
| Jan 8, 2025 | 39134861Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1 (2014 COD... | $1,250 | $1,250 | Mar 19, 2025 |
| Jan 8, 2025 | 39134862K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED PUMPROOM DOOR UNABLE TO OPEN PROPERLY DUE TO THE METAL PLAT... | $1,250 | $1,250 | Mar 19, 2025 |
| Jan 8, 2025 | 39134860R | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED UNSAFE STORAGE(BUCKETS, SHOPVAC, SHOPPING CART, AND BA... | $2,500 | $2,500 | Mar 19, 2025 |
| Nov 21, 2023 | 39099869M | RESOLVE | CLASS - 2 | EMERGENCY EXIT DOORS DO NOT SELF-CLOSE LOCATED THROUGHOUT THE BUILDING., REPAIR/REPLACE DOOR | $312 | $312 | Feb 7, 2024 |
| Nov 21, 2023 | 39099871L | RESOLVE | CLASS - 2 | HOLE PENETRATIONS/CUTOUTS FOUND IN THE BOILER ROOM CELLAR LEVEL., PROVIDE/MAINTAIN FIRE STOPPING | $625 | $625 | Feb 7, 2024 |
| Nov 21, 2023 | 39099838J | RESOLVE | CLASS - 1 | I OBSERVED IN THE BASEMENT BOILER ROOM THE CABLE SUPPLYING POWER TO THE LIGHT WITH THE WIRING EXPOSED AND ENERGIZED T... | $400 | $400 | Aug 22, 2025 |
| Nov 21, 2023 | 39099857P | RESOLVE | CLASS - 2 | RAYPAK BOILER NOT OPERATIONAL, CORRECT VIOLATING CONDITION AND SUBMIT A CERTIFICATE OF CORRECTION. | $310 | $310 | Feb 7, 2024 |
| Nov 21, 2023 | 39099870J | RESOLVE | CLASS - 2 | WOOD BOXED CHIMNEY VENT HAS DETERIORATED EXPOSING THE ROOF TO THE ELEMENT/WHEATHER., REPAIR AND/OR REPLACE | $310 | $310 | Feb 7, 2024 |
| May 24, 2023 | 39087140J | RESOLVE | CLASS - 1 | I OBSERVED THE POWER SUPPLY A FLEXIBLE RUBBER COATED CORD FOR THE SIDEWALK SHED PASSING THROUGH THE WINDOW AND PLUGGE... | $1,600 | $1,522 | Aug 2, 2023 |
| May 24, 2023 | 39087142N | RESOLVE | CLASS - 2 | I OBSERVED IN THE OUTDOOR JUNCTION BOX A DEFECTIVE GFCI OUTLET IN USE. UPON TESTING OF THE GFCI IT FAILED TO TRIP AS ... | $2,400 | $2,400 | Aug 2, 2023 |
| May 24, 2023 | 39087141L | RESOLVE | CLASS - 2 | I OBSERVED THE IMPROPER TERMINATION OF THE SEALTITE RACEWAY- THE RACEWAY WAS UNSECURED AND TAPED TO A FLEXIBLE CORD P... | $1,200 | $1,200 | Aug 2, 2023 |
| Mar 27, 2023 | 39082397M | RESOLVE | CLASS - 2 | OBSERVERED: -CRACKED AND DETERIORATED STUCCO ON ALL SIDES OF THE ROOF BULKHEAD., MAINTAIN EXTERIOR BUILDING WALL; MAI... | $1,250 | $0 | Jun 7, 2023 |
| Mar 11, 2022 | 35644251X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDIN IN CODE COMPLIANT MANNER.OBSERVED AT CELLAR LEVEL MECHANICAL ROOMS & STORAGE ROOMS CEILIN... | $312 | $0 | Aug 31, 2022 |
| Mar 11, 2022 | 39057878Z | RESOLVE | CLASS - 2 | I OBSERVED IN THE STAIRWELL AND IN THE STORAGE AREA ON THE 4TH FLOOR THE INSTALLATION OF CONDUITS JUNCTION BOXES AND ... | $0 | $0 | Jul 13, 2022 |
| Mar 11, 2022 | 35644250Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT ROOF LEVEL STAIRCASE EXTERIOR MORTAR CRACKED MISSIN... | $625 | $0 | Aug 31, 2022 |
| Mar 11, 2022 | 35644252H | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING.OBSERVED AT ROOF & FIRST FLOOR EXP #1 KITCHEN EXIT DOOR DOES NOT SELF CLOSE PROPERLY DUE T... | $312 | $0 | Aug 31, 2022 |
| Mar 11, 2022 | 35644363K | RESOLVE | CLASS - 2 | WORK W/OUT A PERMIT.I OBSERVED NEWLY INSTALLED 3 INCH CAST IRON PIPINGFROM KITCHEN ON 1ST FL GOING THROUGHOUT THE BAS... | $1,250 | $0 | Aug 31, 2022 |
| Dec 17, 2021 | 35649233P | RESOLVE | CLASS - 2 | OUTDOOR ROOF SIGN STRUCTURE USE DISCONTINUED FOR MORE THAN TWO YEARS MUST CONFORM TO CURRENT REGULATIONS.REMEDY:REMOV... | $2,500 | $0 | Jun 10, 2022 |
| Dec 17, 2021 | 35649231L | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY SIGN ON DISPLAY W/O PERMIT (SATURN OF BAY RIDGE) REMEDY:REMOVE ILLEGAL SIGN | $1,250 | $0 | Jun 10, 2022 |
| Dec 17, 2021 | 35649232N | RESOLVE | CLASS - 1 | OUTDOOR ADVERTISING COMPANY FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER SIGN TORN AND SEPARATING FROM IT'S ... | $0 | $0 | Jun 10, 2022 |
| Sep 21, 2021 | 39047873K | RESOLVE | CLASS - 1 | ELEVATED CO READINS 300PPM AT DIVERTER OF LAARS WATER HEATER. CEASE USE ISSUED. CALL DOB 212 393 2784 UPON COMPLETION... | $1,250 | $0 | Jan 26, 2022 |
| Apr 2, 2020 | 37018787Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35383823J ISSUED ON 04/08/19 & TO FILE A CERT OF CORREC... | $3,125 | -$3,125 | Aug 26, 2020 |
| Apr 8, 2019 | 35383823J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVEDAT EXP1 (37 ST) FIRE ESCAPE DROP LADDER DOES NO... | $625 | $0 | Jul 22, 2019 |
| Jan 30, 2019 | 32097593R | ACTIVE | CLASS - 3 | 44C,50,50A. FOUND1 RAYPAK H3-0902B HOT WATER BOILER; 50-MISSING DRIPSON DISCHARGE SIDE OF RELIEF VALVES ON BOILER AND... | $250 | $0 | Aug 7, 2019 |
| Feb 22, 2018 | 35311363P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: EXP#1 FIRE ESCAPE ABOVE MAIN ENTRANCE RUSTED IN SOME PARTS,B... | $0 | $0 | Apr 16, 2018 |
| Feb 22, 2018 | 35311362N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-395. NOTED: FIRE STOP MISSING IN ... | $0 | $0 | Apr 16, 2018 |
| Feb 22, 2018 | 35311364R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: AT ROOF LEVEL UNDEV. STEEL FOR ROOF SIGN OUTER PARTS OF THE W... | $0 | $0 | Apr 16, 2018 |
| Feb 21, 2017 | 35229115N | RESOLVE | CLASS - 2 | 28-301.1 FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6 (1968 CODE) FGG APPENDIX E (E4) 2014 CODE) AT TI... | $0 | $0 | Apr 24, 2017 |
| Feb 21, 2017 | 35229114L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. AT TIME OF MY INSPECTION I OBSERVED ON THE SIDE OF THE BLDG THAT B... | $250 | $0 | Apr 24, 2017 |
| Oct 19, 2016 | 35214520P | RESOLVE | CLASS - 1 | 411.1 MISCELLANEOUS VIOLATION.RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED 10/18/16RESIDENTIAL GAS FLEX... | $1,600 | $0 | Dec 5, 2016 |