ECB violations
4311 4 Avenue, Brooklyn • Block 00729 • Lot 0006
22 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 14, 2020 | 35537195R | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION MEASURES.NO GUARDRAILS.AT TIME OF I... | $2,500 | $0 | Oct 14, 2021 |
| Mar 20, 2020 | 35489742N | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT PRIOR TO COMMENCEMENT OF EARTH WORK(WITHIN 24-48 HRS PRIOR TO START)3 STORY OCCUPIED... | $2,500 | $0 | Feb 25, 2021 |
| Mar 20, 2020 | 35489741L | RESOLVE | CLASS - 1 | BC 1704.1 FAILURE TO FILE SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUANCE AND PRIOR TO START ... | $2,500 | $0 | Dec 28, 2020 |
| Mar 20, 2020 | 35489744R | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.AT TIME OF INSPECTION I OBSERVED ... | $2,500 | $0 | Aug 13, 2021 |
| Jan 8, 2020 | 35359553Z | RESOLVE | CLASS - 2 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE.DEFECTIVE F... | $400 | $0 | Nov 30, 2020 |
| Jan 8, 2020 | 35416815H | RESOLVE | CLASS - 1 | 28-104.8.4=INADEQUATE TPP.NOTE AT TIME OF INSPECTION OBSERVED PERFORMED IN CELLAR UNDER AFORMENTIONED JOB NUMBER STRU... | $2,500 | $0 | Nov 30, 2020 |
| Jan 8, 2020 | 35359554K | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED AT 250PM (1) EXIT LIGHT INSTALLED ON FIRST FLOOR ABOVE DOOR.NO APPLICATION ... | $800 | $0 | Nov 30, 2020 |
| Jan 8, 2020 | 35416816J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN FIRE STOPPING NOTE AT TIME OF INSPECTION OBSERVED ALL FIRESTOPPPING REMOVED FROM CEILING IN CELLA... | $2,500 | $0 | Nov 30, 2020 |
| Jan 8, 2020 | 35416817L | RESOLVE | CLASS - 1 | INADEQUATE HOUSEKEEPING NOET AT TIME OF INSPECTION OBSERVED DUST ADDUMULATION THROUGHOUT BUILDING ON STAIRWELLS,HALLW... | $2,500 | $0 | Nov 30, 2020 |
| Nov 8, 2019 | 39012578H | RESOLVE | CLASS - 1 | OBSERVED THE REMOVAL OF THE FRESH AIR INTAKE PLUMBING PIPE FOR THE HOUSE SEWER SYSTEM WHICH IS NOT CODE COMPLIANT, RE... | $3,125 | $0 | Oct 23, 2020 |
| Nov 8, 2019 | 39012580R | RESOLVE | CLASS - 1 | OBSERVED NEW GAS PIPE AND FITTINGS INSTALLED IN THE CELLAR WITHOUT ANY INSPECTIONS CONDUCTED ON FILE UNDER DOB RECORD... | $6,250 | $0 | Oct 23, 2020 |
| Nov 8, 2019 | 35451372L | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVES AMENDMENTS. @TIME OF INSPECTION 2FT EXCAVATE... | $2,500 | $0 | Jun 8, 2020 |
| Nov 8, 2019 | 35451374P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING A CODE COMPLIANT MANNER: NO FIRE STOPPINGPER BC 712:3, ZA-345. @TIME OF INSPECTION IN RE... | $1,250 | $0 | Jun 8, 2020 |
| Nov 8, 2019 | 39012579J | RESOLVE | CLASS - 1 | OBSERVED 100% NEW GAS PIPE AND FITTINGS INSTALLED IN THE CELLAR WITHOUT ANY PERMITS ON FILE UNDER DOB RECORDS. PARTIA... | $2,530 | $0 | Jan 25, 2021 |
| Nov 8, 2019 | 35359503K | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT PERMIT. OBSERVED AT 12:20PM ELECTRICAL WIRING INSTALLED IN BASEMENT FOR OUTLETS, FIXTURES, SW... | $800 | $0 | Jun 11, 2020 |
| Nov 8, 2019 | 35359504M | RESOLVE | CLASS - 1 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE. DEFECTIVE ... | $1,600 | $0 | Jun 11, 2020 |
| Nov 8, 2019 | 35451373N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE PRTECTION @SIDES OF EXCAVATION. @TIME OF INSPECTION, 6FT EXCAVATION OBSERVED @REAR YARD W/O ALLOY ... | $5,000 | $0 | Jun 8, 2020 |
| Nov 8, 2019 | 35359498P | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY CONNECT CONDUCTORS TO TERMINALS. ARMORED CABLES NOT PROPERLY TERMINATED IN BASEMENT. REMEDY: PROV... | $1,200 | $0 | Jun 11, 2020 |
| Nov 8, 2019 | 39012573Z | RESOLVE | CLASS - 1 | CEASE USE BOILER= BOILER HAS POOR DRAFT-IS SPILLING CO-HAS POOR FLAME-THE CHIMNEY IS REDUCED IN SIZE-THERE IS DEBRIS ... | $1,250 | $0 | Dec 7, 2020 |
| Nov 8, 2019 | 39012574K | RESOLVE | CLASS - 1 | CEASE USE GAS HOT WATER HEATER=IT IS SPILLING 20PPM CO, MAINTAIN BOILER; CORRECT ALL HAZARDOUS CONDITIONS IMMEDIATELY... | $1,250 | $0 | Dec 7, 2020 |
| Nov 8, 2019 | 35359496L | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEM. SERVICE SWITCH NOT PROVIDED WITH GROUND CONDUCTOR. REMEDY: PROVIDE GROUNDING | $4,800 | $0 | Jun 11, 2020 |
| Jan 31, 1994 | 34105688J | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE DEPT. OF BUILDING RECORDS . CELLAR CHANGE FORM ORDINARY TO 1 BEDROOM APT. R... | $0 | $0 | Jul 25, 1994 |