| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jan 27, 2010 | A | VIOLATION CLOSED | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS IN THE FOYER LOC... | E8 | May 2, 2010 |
| Dec 4, 2009 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR AT PUBLI... | — | Dec 10, 2009 |
| Nov 20, 2009 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE E... | B5 | Dec 25, 2009 |
| Nov 20, 2009 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | B5 | Dec 25, 2009 |
| Nov 20, 2009 | B | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 3 SQ. FT ... | B5 | Dec 25, 2009 |
| Oct 19, 2007 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | E2 | Nov 23, 2007 |
| Oct 17, 2007 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | B1 | Dec 10, 2007 |
| Oct 17, 2007 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | B1 | Dec 10, 2007 |
| Oct 16, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK AT CEILING AND WEST WA... | E2 | Nov 20, 2007 |
| Oct 16, 2007 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | B1 | Nov 20, 2007 |
| Oct 16, 2007 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT E2, 5t... | E2 | Nov 20, 2007 |
| Oct 16, 2007 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | E2 | Nov 20, 2007 |
| Oct 16, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FRO... | E2 | Nov 20, 2007 |
| Oct 5, 2007 | B | VIOLATION CLOSED | SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... | B5 | Nov 9, 2007 |
| Oct 5, 2007 | A | VIOLATION CLOSED | SECTION 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAI... | — | Jan 8, 2008 |
| Oct 5, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORS IN THE ENTIRE APAR... | A4 | Nov 9, 2007 |
| Oct 5, 2007 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON OF RISER AT WEST WALL, EAST WALL IN THE BATHROOM LOCATED A... | C9 | Nov 9, 2007 |
| Oct 5, 2007 | B | NOT COMPLIED WITH | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... | C9 | Nov 9, 2007 |
| Oct 5, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON OF RISER AT WEST WALL IN THE BATHROOM LOCATED AT APT B1... | B11 | Nov 9, 2007 |
| Oct 5, 2007 | B | VIOLATION CLOSED | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE E... | B11 | Nov 9, 2007 |
| Oct 5, 2007 | B | VIOLATION CLOSED | SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B5, 2n... | B5 | Nov 9, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, 1st WINDOW... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, EAST WALL,... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, 1st DOOR F... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, 1st DOOR F... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, 1st DOOR F... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE PROVIDE METAL BRACING FOR WINDOW AIR CONDITIONER 2 4 AND 5 STYS WEST WALL OF THE BUILDING | — | Jun 20, 2007 |
| May 4, 2007 | C | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 20 SQ FT AT EAST WALL AT CLOS... | E11 | May 22, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AND MILDEW IN THE 2nd B... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW # 2 IN THE 1st ROOM FROM EAST LOC... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT A... | E11 | Jun 20, 2007 |
| May 4, 2007 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEP... | D11 | Jun 20, 2007 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LIGHT SWITCH NORTH WALL EAST ROOM 4 STY SOUTHEAST A... | D11 | Feb 29, 2000 |
| May 4, 2007 | B | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ,, 1st WINDOW... | E11 | Jun 20, 2007 |
| Aug 29, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT WALLS CEILINGS & STE... | C9 | Sep 18, 1995 |
| Aug 29, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT WALLS CLOSET & DOORS... | C9 | Sep 18, 1995 |
| Aug 29, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT ENTRANCE DOOR TO APT... | — | Sep 18, 1995 |
| Aug 29, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT WEST WALL CENTER ROO... | C9 | Sep 18, 1995 |
| Aug 29, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT WALLS & STEAM RISER ... | C9 | Sep 18, 1995 |
| Apr 4, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AND ALL WALL... | D5 | Apr 24, 1995 |
| Apr 4, 1995 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AND ALL WALL... | D5 | Apr 24, 1995 |
| Feb 5, 1991 | C | DEFECT LETTER ISSUED | § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING AND SOUTH WA... | B5 | Feb 25, 1991 |