ECB violations
545 46 Street, Brooklyn • Block 00748 • Lot 0057
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 15, 2019 | 39012939Y | RESOLVE | CLASS - 2 | I OBSERVED IN THE CELLAR AREA OF THE GAS METER ROOM, COMBUSTIBLE MATERIAL BEING STORED IN THE GAS METER ROOM, WHICH I... | $312 | $0 | Jun 19, 2020 |
| Nov 15, 2019 | 39012940L | RESOLVE | CLASS - 1 | I OBSERVED IN THE CELLAR AREA OF THE BUILDING, NEWLY INSTALLED GAS PIPING FOR 16 GAS METERS IN THE CELLAR WITHOUT A P... | $1,250 | $0 | Jun 19, 2020 |
| Nov 15, 2019 | 39012930H | ACTIVE | CLASS - 2 | COLD WATER THERMO LOOP ON HOLBY MIXING VALVE IS NOT MIN 27" DOWN; CORRECT VIOLATIONS AND SUBMIT THE CERTIFICATE OF CO... | $312 | $0 | Jun 19, 2020 |
| Feb 22, 2019 | 39001424L | RESOLVE | CLASS - 2 | HOLES IN OIL TANK ROOM+GAS METER ROOM-PIPE LEAKING AT CONDENSATE TANK-BOTTOM DRAIN COCK CORRODED-COLD WATER THERMO LO... | $0 | $0 | Jul 22, 2019 |
| Jul 31, 2013 | 35021431M | RESOLVE | CLASS - 1 | VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS.CONTINUOUS CONTINUITY OF GROUND OF METALLIC RACEWAYS AND CABLES ... | $4,000 | $0 | Nov 4, 2013 |
| Jul 31, 2013 | 35021429N | RESOLVE | CLASS - 1 | VIOLATION OF ELECTRICAL CODE TECHNICAL STANDARDS. PLUG FUSES ARE IN USE BASENT,APT CIRCUITS AT 11:30AM OBSERVED IN BA... | $4,000 | $0 | Nov 4, 2013 |
| Jul 31, 2013 | 35021430K | RESOLVE | CLASS - 1 | FAILURE TO PROTECT CONDUCTORS AGAINST OVERCURRENT PER EC OVER FUSED BRANCH CIRCUIT IN BASEMENT 20 AMP FUSES ON #14 AW... | $12,000 | $0 | Nov 4, 2013 |
| Mar 1, 2013 | 34746918X | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO AND DOB RECORDS CLASS"A"APTCONVERTED INTO 3 SINGLE ROOM OCCUPANCIES WITH F... | $6,000 | $0 | Jul 15, 2013 |
| Feb 13, 2013 | 34746921R | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO AND DOB RECORDS CLASS"A"APT#4M CONVERTED INTO 4 SINGLE ROOM OCCUPANCIES.GA... | $6,000 | $0 | Jul 15, 2013 |
| Feb 13, 2013 | 34746922Z | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO AND DOB RECORDS 3RD STORY CLASS"A"APT 3J CONVERTED INTO 4 SINGLE ROOM OCCU... | $3,000 | $0 | Jul 15, 2013 |
| Dec 8, 2012 | 32072902K | RESOLVE | CLASS - 1 | B154,15,21B,25A,B,32B,4B,16,26,45A,B,50,50A. 4B- HAZARDOUS - REPAIR/REPLACE IMMEDIATELY. 50A- ELECTRICAL WIRES ARE BU... | $2,500 | $0 | Jan 28, 2013 |
| Dec 6, 2012 | 32072490N | RESOLVE | CLASS - 2 | 2B254,16,42,50EFGH,15,32A,50ABCD. FOUND ROCKMILLS MP100 WITH DEFECTS 50 DEBRIS IN BOILER ROOM;50A-DISCHARGE PIPE MISS... | $1,250 | $0 | Jan 28, 2013 |
| Jul 10, 2012 | 34991363K | RESOLVE | CLASS - 1 | BURNED ELECTRICAL SERVICE SWITCHES AND FUSE BLOCKS WERE REUSED AFTER A FIRE AND DAMAGE TO FEEDER INSULATION DEFECTIVE... | $4,000 | $0 | Aug 27, 2012 |
| Jul 10, 2012 | 34942811Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER.@ TIME OF INSPEC OBSERVED RUBBLE STONE RETAINING WALL @ REAR YARD... | $1,250 | $0 | Feb 4, 2013 |
| Jul 10, 2012 | 34991362Z | RESOLVE | CLASS - 1 | NO ELECTRICAL PERMIT APPLICATION IS ON FILE FOR THE REPLACEMENT OF A 100AMP SERVICE SWITCH AND REPAIRED SERVICE ENTRA... | $4,000 | $0 | Aug 27, 2012 |
| Jul 10, 2012 | 34991361R | RESOLVE | CLASS - 1 | THE OWNERS REPLACE THE EXISTING SERVICE SWITCH AND INSTALLED A 100AMP 3PHASE REPLACEMENT SERVICE SWITCH SERVICE ENTRA... | $12,500 | $0 | Aug 27, 2012 |
| Mar 14, 2012 | 34985757M | RESOLVE | CLASS - 1 | WORK W/O PERMIT.WORK NOTED:RENOVATION IN PROGRESS @ APT 1A.PLUMBING LINES BEING REMOVED IN KITCHEN.CEILING IN PROCESS... | $8,000 | $0 | Aug 27, 2012 |
| Jul 15, 2011 | 34970309R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMM ORDER TO FILE A CERT OF CORRECTION W/ THE DOB FOR NOV#3487899M ISSUED ON 08/21/10 PURSU... | $2,000 | $0 | Oct 3, 2011 |
| Mar 15, 2011 | 34906467X | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY W/AN ORDER OF THE COMM'S RESPONDENT FAILED TO CORRECT THE CONDITIONS CITED IN NOV#348... | $24,000 | $0 | May 2, 2011 |
| Jan 4, 2011 | 34896877M | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY W/ AN ORDER OF THE COMM.NOTED:RESPONDENT FAILED TO CORRECT THE CONDITIONS CITED IN TH... | $12,000 | $0 | Feb 28, 2011 |
| Oct 8, 2010 | 34877279Z | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER NOTE:RESPONDENT FAILED TO CORRECT THE CONDITION(S) ... | $12,000 | $0 | Nov 29, 2010 |
| Oct 8, 2010 | 34877278R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL OR APPURTENANCE. NOTE: AT REAR YARD WEST WALL OF BUILDING HAS NUMEROUS STE... | $10,000 | $0 | Nov 29, 2010 |
| Aug 21, 2010 | 34871899M | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN EXTERIOR BLDG WALL OR APPURTENANCE.NOTED: @ REAR COURT YARD WESTWALL OF BLDG STEP CRACKS EVIDENT ABO... | $10,000 | $0 | Oct 18, 2010 |
| Apr 10, 2010 | 34839266M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BLDG WALL OR APPURTENANCE NOTED: @ REAR COURTYARD WEST WALL OF BLDG STEP-CRACKS EVIDENT ... | $10,000 | $0 | Jun 7, 2010 |
| Nov 12, 2009 | 34818345H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM ORDER TO FILE A COFC W/THE DOB NOTED:RESPFAILED TO COMPLY W/THE COMM ORDER TO CORRECT TH... | $4,000 | $0 | Jul 19, 2010 |
| Nov 12, 2009 | 34818344X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR SPPURTENANCES NOTED:@ EXPOSURE #2 (NORTH-WEST FACADE)THERE ARE VERTICAL CRACKS IN T... | $10,000 | $0 | Mar 1, 2010 |
| Jun 22, 2009 | 34781832Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG INTERIOR DEFECTS NOTED APPROX 10CUYDS DEBRIS AT BSMT LVL GARBAGE & DEBRIS THROUGHOUT BSMT OP... | $5,000 | $0 | Aug 24, 2009 |
| Jun 22, 2009 | 34781833K | RESOLVE | CLASS - 1 | VIOLATION FOR FAILURE TO MAINTAIN BLDG EXTERIOR DEFECTS NOTED AT EXP#2 STREAK CRACKS AT BRICK WALL UNDER 2ND STORY WI... | $5,000 | $0 | Aug 24, 2009 |
| Oct 17, 2003 | 34386943L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALLS/DEFECTS NOTED/STEP CRACKING EVIDENT AT REAR AND SIDEWALL EXPOSURES-VARIOUS LO... | $0 | $0 | Dec 8, 2003 |
| Nov 13, 1991 | 34063511L | RESOLVE | Hazardous | MULTIPLE GAS METERS INSTALLED AT REAR HALF OF BASEMENT IN SAME AREA ASTHE BOILER, CONTRARY TO BUILDING CODE. REMEDY: ... | $345 | $0 | May 11, 1992 |
| Nov 13, 1991 | 34063510J | RESOLVE | Hazardous | NO FIREPROOF ENCLOSURE FOR A BOILER. BOILER NOT SEPARATED FROM THE REST OF THE BUILDING IN THAT IT IS NOT SEPARATELY ... | $460 | $0 | May 11, 1992 |