Issued Class Status Violation Apartment Correct by
Mar 7, 2013 B VIOLATION CLOSED SECTION 27-2077, 2078 ADM CODE DISCONTINUE UNLAWFUL USE FOR SINGLE ROOM OCCUPANCY PURPOSES ANNA MONTEZ, TEODULFA MEZA... 1C Apr 11, 2013
Mar 7, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SINK CABINET IN THE KITCHEN LOCATED AT APT 1C, 1st ... 1C Mar 13, 2013
Mar 7, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN... 1C Mar 13, 2013
Mar 7, 2013 C VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT WINDOW LOWER SASH IN THE BATHROOM LOCATED A... 3K Mar 13, 2013
Mar 7, 2013 C VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE APARTMENT ENTRANCE DOOR IN THE PRIVATE HALLWAY LOCATED AT... 3K Mar 13, 2013
Mar 7, 2013 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3K, 3rd STORY,... 3K Apr 11, 2013
Mar 7, 2013 B VIOLATION CLOSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... 3K Apr 11, 2013
Mar 7, 2013 C VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT 1ST AND 2ND FROM SOUTH AT WEST WINDOW ... 3K Mar 13, 2013
Mar 7, 2013 C VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT 1ST FROM WEST AT NORTH WINDOW LOWER SASH IN... 3K Mar 13, 2013
Mar 7, 2013 C VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... 3K Mar 13, 2013
Mar 7, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL STAIRS CASE LEADING TO THE STREET AT FIRE PAS... Mar 13, 2013
Mar 5, 2013 C VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATE... 1A Mar 11, 2013
Feb 27, 2013 B VIOLATION CLOSED § 27-2077, 2078 ADM CODE DISCONTINUE UNLAWFUL USE FOR SINGLE ROOM OCCUPANCY PURPOSES LEIDI CHANAX, JOHN DOE, JOHN DOE... 3J Apr 3, 2013
Feb 27, 2013 C VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... 3J Mar 5, 2013
Feb 27, 2013 C VIOLATION CLOSED § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC ... 3J Mar 5, 2013
Feb 26, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR LEADING TO WEST COURT YARD AT PUBLIC HALL, 1st... Mar 4, 2013
Feb 26, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TERRACOTTA CAPING AT ALL PARAPET WALLS Mar 4, 2013
Feb 26, 2013 B VIOLATION CLOSED § 27-2077, 2078 ADM CODE DISCONTINUE UNLAWFUL USE FOR SINGLE ROOM OCCUPANCY PURPOSES JOVITA ORTIZ, JOHN DOE, JOHN DOE... 4M Apr 2, 2013
Feb 25, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK PARAPET WALL AT NORTH OF... Mar 3, 2013
Feb 25, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 4th STORY Mar 3, 2013
Feb 25, 2013 A VIOLATION CLOSED § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... 3J May 31, 2013
Feb 25, 2013 C VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH FIRE ESCAPE WIND... 4M Mar 3, 2013
Feb 25, 2013 A VIOLATION CLOSED § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... 4M May 31, 2013
Feb 25, 2013 C VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH FIRE ESCAPE WIND... 4M Mar 3, 2013
Feb 25, 2013 A VIOLATION CLOSED § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... 4M May 31, 2013
Feb 25, 2013 C VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH FIRE ESCAPE WIND... 3J Mar 3, 2013
Feb 25, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LOCK AT VESTIBULE ENTRANCE DOOR AT PUBLIC HALL, 1st STORY Mar 3, 2013
Feb 25, 2013 A VIOLATION CLOSED § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... 3J May 31, 2013
Feb 25, 2013 C VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE PIPE IN GAS METERS ROOM AT BASEMENT Mar 3, 2013
Feb 25, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BUIDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY Mar 3, 2013
Feb 25, 2013 C VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT STEAM DISTRIBUTION PIPE IN GAS METERS ROOM AT BASEMENT Mar 3, 2013
Feb 25, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE NORTH AND SOUTH BULKHEAD DOORS AT PUBLIC HALL, 4th ... Mar 3, 2013
Feb 20, 2013 C VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT RADIATOR SHUT OFF VALVE IN THE 1st ROOM FROM NORTH LO... 4O Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH FIRE ESCAP... 4O Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT 1ST FROM WEST AT NORTH WINDOW LOWER S... 4O Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT WINDOW LOWER SASHES IN THE KITCH... 4O Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPEC... 4O Mar 13, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE FOYER LOCATED AT APT 4O, 4th STOR... 4O Feb 26, 2013
Feb 20, 2013 B VIOLATION CLOSED SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELE... 4O Mar 27, 2013
Feb 20, 2013 B VIOLATION CLOSED SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT L... 4O Mar 27, 2013
Feb 20, 2013 B VIOLATION CLOSED SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4O, 4t... 4O Mar 27, 2013
Feb 20, 2013 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 2F Mar 27, 2013
Feb 20, 2013 C VIOLATION CLOSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 2F Mar 13, 2013
Feb 20, 2013 B VIOLATION CLOSED SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT L... 2F Mar 27, 2013
Feb 20, 2013 B VIOLATION CLOSED SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd ... 2F Mar 27, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHRO... 2F Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN... 2F Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCA... 2F Feb 26, 2013
Feb 20, 2013 C VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AT APARTMENT ENTRANCE DOOR IN THE FOYER LOCATED AT AP... 2F Feb 26, 2013
Feb 20, 2013 C VIOLATION DISMISSED SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPEC... 1D Mar 13, 2013