ECB violations
5216 4 Avenue, Brooklyn • Block 00806 • Lot 0043
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 19, 2026 | 39554299L | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE AT 3-STORY BUILDING ERECTED UNDER EXPIRED PERMIT. FAILURE TO MAINT... | $0 | $0 | Aug 5, 2026 |
| Sep 4, 2024 | 39532061Y | RESOLVE | CLASS - 2 | SITE CLOSED NO ACTIVITY. GATE IS LOCKED UP. RESPONDENT FAILED TO COMPLY WITH COMMISSIONERS ORDERS AND FILE FOR A CERT... | $1,250 | $0 | Nov 13, 2024 |
| Sep 4, 2024 | 39532064J | RESOLVE | CLASS - 2 | SITE CLOSED NO ACTIVITY. GATE IS LOCKED UP. CONSTRUCTION SUPER FAILED TO COMPLY WITH COMMISSIONERS ORDERS AND FILE FO... | $1,250 | $0 | Nov 13, 2024 |
| Jul 23, 2024 | 39119641L | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. FENCE OR SIDEWALK SHED. EXIST PERMIT #B00198224-I1-FN HAVE E... | $0 | $0 | Oct 2, 2024 |
| Jul 5, 2024 | 39530272P | RESOLVE | CLASS - 1 | AN INCIDENT OCCURRED ON JULY 3RD 2024 WHERE A SECTION OF EXTERIOR WALL STUCCO ON THE BUILDING AT EXPOSURE # 4 FELL ON... | $5,000 | $0 | Aug 12, 2025 |
| Jul 5, 2024 | 39530273R | RESOLVE | CLASS - 1 | AN INCIDENT OCCURRED ON JULY 3RD 2024 WHERE A SECTION OF EXTERIOR WALL STUCCO ON THE BUILDING AT EXPOSURE # 4 FELL ON... | $2,500 | $0 | Sep 11, 2024 |
| Jul 3, 2024 | 39118413P | RESOLVE | CLASS - 1 | SUMMONS ISSUED FOR FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS DUE TO A SECTION... | $25,000 | $0 | Aug 12, 2025 |
| Oct 20, 2023 | 39522765N | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION I OBSERVED NEEDLE BEAMS INSTALLED AT EXP. # 2 AND EXP. # 3.I SEARCHED ON DOB SYSTEM AND APP... | $1,250 | $0 | Dec 27, 2023 |
| Jun 29, 2023 | 39518497Y | RESOLVE | CLASS - 1 | CONTRACTOR FAILED TO INSTALL GUARD RAILS AT THE STAIRCASE AREA LEADING TO 4TH FLOOR & STAIRCASE AT THE ROOF LEVEL & T... | $2,500 | $0 | Sep 6, 2023 |
| Jun 29, 2023 | 39518496M | RESOLVE | CLASS - 1 | CONTRACTOR FAILED TO HAVE SUPERINTENDENT PRESENT AT THE JOB SITE AS REQUIRED, THERE HAS BEEN NO RECORD OF SIGN IN/OUT... | $10,000 | $0 | Sep 6, 2023 |
| Jun 29, 2023 | 39518494Z | RESOLVE | CLASS - 2 | CONTRACTOR FAILED TO PROVIDE THE DAILY INSPECTIONS FOR SIDEWALK SHED & SUPPORTED SCAFFOLD AS REQUIRED. THIS CONDITION... | $0 | $0 | Sep 6, 2023 |
| Jun 29, 2023 | 39518495K | RESOLVE | CLASS - 2 | CONTRACTOR FAILED TO HAVE SIDEWALK SHED INSTALLED AS PER APPROVED DRAWINGS, SWS HEIGHT IS CONTRARY TO THE APPROVED DR... | $0 | $0 | Sep 6, 2023 |
| Jun 28, 2023 | 39518469R | RESOLVE | CLASS - 2 | CONTRACTOR FAILED TO PERFORM PROPER CONCRETE PROCEDURES, OBSERVED CONCRETE BEING WASHED INTO SEWER. THIS IS A CLEAR V... | $0 | $0 | Sep 6, 2023 |
| Jun 28, 2023 | 39518471X | RESOLVE | CLASS - 2 | OBSERVED WORK BEING CONDUCTED AT THE ROOF LEVEL W/ OUT A FULL CONTROL ACCESS ZONE OR FULL SAFETY MEASURES IN STALLED,... | $0 | $0 | Sep 6, 2023 |
| Jun 28, 2023 | 39518470Y | RESOLVE | CLASS - 2 | OBSERVED STREET OPERATIONS BEING CONDUCTED W/ OUT DOT PERMIT FOR ROADWAY OCCUPANCY. THIS IS A CLEAR VIOLATION AND IS ... | $0 | $0 | Feb 26, 2024 |
| May 26, 2022 | 35586337Y | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT MAINTAINED PURSUANT TO SUBSECTION.AT TIME OF INSPECTION OBSERVED CONSTRUCTION FENCE ON EXP #1 WITH... | $0 | $0 | Oct 19, 2022 |
| Sep 10, 2021 | 35589707X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SIDEWALK SHED FOR PEDESTRIAN AS OHP.AT THE TIME OF INSPECTION A PROPOSED 4 STORY BUILDING OBSERVED... | $10,000 | $0 | Sep 2, 2022 |
| Jun 22, 2021 | 35557103Z | RESOLVE | CLASS - 2 | TEMPORARU CONSTRUCTION EQUIPMENT-EXPIRED PERMIT FOR CONSTRUCTION FENCEAT TIME OF INSPECTION OBSERVED CONSTRUCTION FEN... | $0 | $0 | Nov 3, 2021 |
| Dec 5, 2019 | 35464403H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE DRAWINGS FOR BRACING & SHORING OF STRUCTURAL WALL.AT TIME OF INSPECITON ON AN ACTIVE 4 STORY ALT C... | $625 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464406N | RESOLVE | CLASS - 1 | BC3314-FAILURE TO MAINTAIN PIPE SCAFFOLD AS PER CODE.AT TIME OF INSPECTION ON AN ACTIVE 4 STORY ALT CONSTRUCTION SITE... | $2,500 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464407P | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE SAFETY EQUIPMENT-NO GUARD RAILS.AT TIME OF INSPECTION ON AN ACTIVE 4 STORY ALT CONSTRUCTION SITE... | $2,500 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464408R | RESOLVE | CLASS - 1 | PRE-SHIFT SAFETY MEETING.AT TIME OF INSPECITON ON AN ACTIVE 4 STORY ALT CONSTRUCTION SITE,WHEN THE COMPETENT PERSON W... | $5,000 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464400M | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER RULE.AT TIME OF INSPECTION ON AN ACTIVE 4 STORY ALT CONST... | $5,000 | $0 | Jan 28, 2021 |
| Dec 5, 2019 | 35464401Y | RESOLVE | CLASS - 1 | BC33103-FAILURE TO PROVIDE/MAINTAIN SITE SAFETY PLAN ON SITE AS PER CODE.AT TIME OF INSPECTION ON AN ACTIVE 4 STORY A... | $2,500 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464402X | RESOLVE | CLASS - 1 | BC330311-FAILURE TO PROVIDE ADEQUATE MEANS OF EGRESS.AT TIME OF INSPECTION ON AN ACTIVE 4 STORY ALT CONSTRUCTION SITE... | $2,500 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464404J | RESOLVE | CLASS - 1 | BC33091-FAILURE TO PROTECT OR ADEQUATE PROTECT ADJOINING PROPERTIES.ATTIME OF INSPECTION ON AN ACTIVE 4 STORY ALT CON... | $2,500 | $0 | Mar 8, 2021 |
| Dec 5, 2019 | 35464405L | RESOLVE | CLASS - 1 | BC33073-FAILURE TO PROVIDE/MAINTAIN ADEQUATE OVERHEAD PROTECTION.AT TIME OF INSPECITON ON AN ACTIVE 4 STORY ALT CONST... | $2,500 | $0 | Mar 8, 2021 |
| Aug 7, 2001 | 34299691Z | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTICATE OF OCCUPANCY JOB # 300520577 TEMP C OF O EXP 11/26/1999 REMDY : O... | $350 | $0 | Mar 10, 2003 |
| Oct 6, 1999 | 34215813R | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE APPROVED PLANS NOTE AT TIME OF INSPECTION,NO APPROVED PLANS PROVIDED FOR PERMIT #3003202577 ISSUED... | $130 | $0 | Apr 10, 2000 |
| Sep 14, 1999 | 34207486Z | RESOLVE | Hazardous | THE DECORATIVE, BRICKWORK AT THE 2ND FLOOR HAS UNKEYED FROM THE WOODENEXTERIOR WALL AND COLLAPSED. THE WOODEN ENCLOSU... | $2,500 | $0 | Dec 20, 1999 |
| May 14, 1990 | 34040587X | RESOLVE | Non-Hazardous | ALTERED BLDG OCCUPIED WITHOUT A VALID C OF O UNDER APPL. ALT. #1384/89REMEDY: OBTAIN A C OF FROM THIS DEPT. | $285 | $0 | Jun 25, 1990 |