ECB violations
273 GARAGE 56 Street, Brooklyn • Block 00829 • Lot 0043
23 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 21, 2026 | 39185465R | ACTIVE | CLASS - 2 | OBSERVED ONE GAS FIRED LAARS VW0500 500000BTU HOT WATER BOILER UNREGISTERED CORRECT ALL VIOLATING CONDITIONS | $1,250 | $1,250 | Jan 25, 2027 |
| Feb 13, 2025 | 39138375L | RESOLVE | CLASS - 1 | . AT TIME OF INSPECTION OF A 4 STORY BUILDING OBSERVED BUILDING WALL APPUERTANANCES AT THE 2ND TO THE 4TH FLOOR FOR C... | $2,500 | $2,500 | Mar 12, 2026 |
| Feb 13, 2025 | 39138376N | RESOLVE | CLASS - 2 | FOR AC UNIT NOT HAVING SUPPORT BRACKETS AT EXPOSURE 2, REPAIR AND/OR REPLACE | $625 | $625 | Mar 12, 2026 |
| Feb 6, 2017 | 32087365X | ACTIVE | CLASS - 2 | AS PER CLASS 2 (B265) 28-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS. SUBMIT A CURRE... | $500 | $0 | May 2, 2017 |
| Jan 13, 2016 | 35048218N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMM'S ORDER CONTAINED IN NOV#35154351L ISSUED ON 11/21/15 & TO FILE A CERT OF CORRECTION PU... | $800 | $0 | May 23, 2016 |
| Nov 21, 2015 | 35154351L | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTE: AT EXP2 MASONRY STONES FROM SECOND TO FOURTH FLR ARE CRACK AND ... | $1,000 | $0 | May 23, 2016 |
| Apr 4, 2013 | 32073020N | ACTIVE | CLASS - 1 | B154,1,49. 1- OPERATING A SEALED BOILER - DOB WAS NOT NOTIFIED AS PERVIOLATION #32072174L TO REMOVE SEAL AFTER REPAIR... | $5,000 | $0 | May 20, 2013 |
| Apr 4, 2013 | 32073017M | ACTIVE | CLASS - 1 | B154,1,49. 1- OPERATION OF A SEALED BOILER - DOB WAS NOT NOTIFIED AS PER VIOLATION #32072171X TO REMOVAL SEAL AFTER R... | $5,000 | $0 | May 20, 2013 |
| Apr 4, 2013 | 32073015Z | ACTIVE | CLASS - 1 | B154,1,49. 1- OPERATION OF A SEALED BOILER - DOB WAS NOT NOTIFIED AS PER VIOLATION #32072169R TO REMOVE SEAL AFTER RE... | $5,000 | $0 | May 20, 2013 |
| Apr 4, 2013 | 32073018Y | RESOLVE | CLASS - 1 | 1- OPERATION OF A SEALED BOILER - DOB WAS NOT NOTIFIED AS PER VIOLATION #32072172H TO REMOVE SEAL AFTER REPAIRS. BOIL... | $5,000 | $0 | May 20, 2013 |
| Apr 4, 2013 | 32073019X | ACTIVE | CLASS - 1 | B154,1,49. 1- OPERATION OF A SEALED BOILER - DOB WAS NOT NOTIFIED AS PER VIOLATION #32072173J TO REMOVE SEAL AFTER RE... | $5,000 | $0 | May 20, 2013 |
| Apr 4, 2013 | 32073016K | ACTIVE | CLASS - 1 | B154,1,49. 1- OPERATION OF A SEALED BOILER - DOB WAS NOT NOTIFIED AS PER VIOLATION #32072170Y TO REMOVE SEAL AFTER RE... | $5,000 | $0 | May 20, 2013 |
| Aug 10, 2012 | 32072172H | RESOLVE | CLASS - 2 | 4B,19,B254,51,32A: 4B;HAZARDOUS WIRING IS CUT. 19;INCORRECTLY INSTALLED WEIL MCLAIN CG-30 62,000BTU. DO NOT OPERATE B... | $2,500 | $0 | Oct 1, 2012 |
| Aug 10, 2012 | 32072173J | RESOLVE | CLASS - 2 | 4B,19,B354,51,32A: 4B;HAZARDOUS WIRES ARE CUT. 19;INCORRECTLY INSTALLED WEIL MCLAIN CG30 62,000 BTU DO NOT OPERATE BO... | $2,500 | $0 | Oct 1, 2012 |
| Aug 10, 2012 | 32072169R | ACTIVE | CLASS - 2 | 4B,19,32A,51,B254: 4B;HAZARDOUS WIRING IS CUT. 19;INCORRECTLY INSTALLED WEIL MCLAIN BOILER CG30 62,000 BTU DO NOT OPE... | $2,500 | $0 | Oct 1, 2012 |
| Aug 10, 2012 | 32072170Y | ACTIVE | CLASS - 2 | 4B,19,32A,51,B254: 4B;HAZARDOUS WIRING IS CUT. 19;INCORRECTLY INSTALLED WEIL MCLAIN CG30 62,000 BTU DO NOT OPERATE BO... | $2,500 | $0 | Oct 1, 2012 |
| Aug 10, 2012 | 32072171X | ACTIVE | CLASS - 2 | 4B,19,32A,51,B254: 4B;HAZARDOUS WIRING IS CUT. 19;INCORRECTLY INSTALLED WEIL MCLAIN CG 30 62,000 BTU DO NOT OPERATE B... | $2,500 | $0 | Oct 1, 2012 |
| Aug 10, 2012 | 32072174L | ACTIVE | CLASS - 2 | 4B,19,B254,51,32A: 4B;HAZARDOUS WIRES ARE CUT. 19;INCORRECTLY INSTALLED WEIL MCLAIN CG 30. DO NOT OPERATE THE BOILER ... | $2,500 | $0 | Oct 1, 2012 |
| Aug 13, 2001 | 34300734P | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING HAZARDOUS DEFECT NOTED: BRICK PIER FOR CENTER LINE BEAM DEFECTIVE DUE TO SERVERE LEANING... | $800 | $0 | Oct 29, 2001 |
| Aug 9, 2001 | 34300733N | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE/MAINTAIN FIRE STOPPING WHERE REQUIRED AT CEILING LEVEL AT VARIOUS LOCATION THROUGHOUT CELLAR FIRE ... | $350 | $0 | Oct 29, 2001 |
| Aug 18, 1999 | 34221107K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR AND INTERIOR BUILDING ALL DEFECTS ARE BROKEN SAGGING FLOOR PUBLIC BALL. LOOSE SAGGING AN... | $2,500 | $0 | Oct 4, 1999 |
| Jun 15, 1999 | 34194501H | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING. HAZARDOUS DEFECTS ARE: AT FIRE ESCAPE (3RD AVE SIDE): PROFOUND CORROSION EVIDENT ENTIRE... | $2,500 | $0 | Aug 2, 1999 |
| Mar 12, 1992 | 34069296P | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTICAT OF OCCUPANCY. ALTERATION # 1047/1990 NO SIGN OFF IN DEPT. OFFICAL ... | $0 | $0 | May 18, 1992 |