Skip to content

ECB violations

263-267 6 Street, Brooklyn • Block 00987 • Lot 0001

41 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 31, 2021 35548759R RESOLVE CLASS - 1 FAILURE TO TAKE PROVIDE SFATEY MEASURES SUCH AS SIDEWLKA SHED FENCE ETC WHERE REQUIRED TO PROTETCT AND SECURE PUBLIC ... $10,000 $0 Aug 11, 2021
Mar 31, 2021 35548760Y RESOLVE CLASS - 1 FAILURE TO MAINTAIN EXTEIROR BUILDING FACADE AND APPURTENANCES NOTE AT THE TIME OF MY INSPECTION OBSERVED HORIZONTAL ... $2,500 $0 Aug 11, 2021
Apr 8, 2020 39020828L RESOLVE CLASS - 1 IMPROPER FUSING ON THE CONTROLLER BYPASS. NO ACCESS TO THE HOISTWAY MISSING THE SCHINDLER HOISTWAY KEY. NO ACCESS TO ... $1,250 $0 Dec 3, 2020
Apr 8, 2020 39020829N RESOLVE CLASS - 1 IMPROPER FUSING ON THE CONTROLLER BYPASS. NO ACCESS TO THE HOISTWAY MISSING SCHINDLER HOISTWAY KEY. NO ACCESS TO THE ... $1,250 $0 Dec 3, 2020
Mar 12, 2020 39019524Y RESOLVE CLASS - 2 PROVIDE KEYS TO GAIN ACCESS TO THE PIT., PROVIDE KEYS TO GAIN ACCESS TO THE TOP OF CAR. $625 $0 Dec 28, 2020
Dec 12, 2016 32086088M RESOLVE CLASS - 2 50A PRESSURE RELIEF VALVE LEAKING. $500 $0 Feb 6, 2017
Mar 9, 2016 35035328L RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTE:@TIME OF INSP OBS THE BALCONIES AT THE 9,10,11 FLRS @EXP #... $0 $0 Apr 25, 2016
Jun 19, 2013 35019314K RESOLVE CLASS - 1 USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERTIFICATE. AT THE TIMEOF MY INSPECTION. I OBSERVED 1 WORKER USING A S... $8,000 $0 Aug 5, 2013
Jun 19, 2013 35019313Z RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONST - NO GUARD RAILS OR TOE BOARD. AT THE TIME... $12,000 $0 Aug 5, 2013
Jun 19, 2013 35019312R RESOLVE CLASS - 1 SEC. 3314.5 WORKING PLATFORM ON SUPPORTED SCAFFOLD NOT FULLY PLANK. ATTHE TIME OF MY INSPECTION AT A ACTIVE CONST. SI... $8,000 $0 Aug 5, 2013
May 17, 2013 35018825H RESOLVE CLASS - 1 SITE SAFETY MAGR/COORDINATOR FAILED TO IMMEDIATELY NOTIFY DOB OF CONDITIONS REQUIRED SITE SAFETY MGR STATED ACCIDENT ... $2,500 $0 Aug 26, 2013
May 17, 2013 35016447K RESOLVE CLASS - 1 BC3307.7 FULL*SWO*JOB SITE FENCE NOT CONST TO CODE.SLIDING GATE @EXP 4NOT CONST PROPERLY.@APPROX 4:20PM ON 5/16/13,SI... $1,600 $0 Sep 25, 2013
May 17, 2013 35016448M RESOLVE CLASS - 1 BC3308.1.1 FAIL TO MAINTAIN VERTICAL NETS.NOTE:VERTICAL NETS DAMAGED & NOT PROPERLY INSTALLED @EXP#4 BY HOIST RUN;HOI... $1,600 $0 Oct 2, 2013
May 17, 2013 35016449Y RESOLVE CLASS - 1 FAIL TO PROVIDE GUARD RAILS.NOTED:@EXP #4 AT EDGE OF BLDG NO GUARD RAIL SYSTEM FOR OPEN AREAS.ONGOING WORK @TIME OF I... $2,400 $0 Oct 2, 2013
May 17, 2013 35018276Y RESOLVE CLASS - 2 BC3303.8.2 FAIL TO PROVIDE METAL SIGN FOR STAND PIPE SIAMESE CONNECTION.NOTE:NO SIGN FOR SIAMESE CONNECTION LOCATION.... $0 $0 Jul 1, 2013
May 17, 2013 35018275M RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTE:EXIT PASSAGEWAYS BLOCKED BY DEBRIS & CONSTRUCTION MATERIALS THRU... $0 $0 Oct 2, 2013
May 2, 2013 35017006J RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLAN AT JOB SITE. AT TIME OF INSPNO APPROVED ENGINEERED PLANS FOR SIDEWALK SHED ... $250 $0 Aug 26, 2013
May 2, 2013 35017005H RESOLVE CLASS - 2 SEC. BC 3310.8.3. FAILURE TO COMPLY W/RULES PROMULGATED BY THE COMMISSIONER - SITE SAFETY RULE AT TIME OF INSPECTION ... $0 $0 Jun 17, 2013
Jan 29, 2013 35003444M RESOLVE CLASS - 1 FAIL TO INSTITUTE/MAINTAIN SAFETY EQUIP MEASURES - NO HANDRAILS.NOTED:HANDRAILS HAVE BEEN REMOVED @THE FOLLOWING FLOO... $1,000 $0 Mar 18, 2013
Jan 29, 2013 35003445Y RESOLVE CLASS - 1 FAIL TO SAFEGUARD ALL PERSONS/PROP AFFECTED BY CONST OPERATIONS.NOTED:@10TH&11TH FLRS BY HOIST AREA NETTING HAS BEEN ... $1,200 $0 Mar 26, 2013
Oct 23, 2012 34907862K RESOLVE CLASS - 1 SEC. 3314.4.1. INSTALLATION - NOTED AT TIME OF INSPECTION OBSERVED MENWORKING ON SCAFFOLD DOING STUCCO WORK WHILE SCA... $1,600 -$1,600 Dec 31, 2012
Oct 23, 2012 34907863M RESOLVE CLASS - 1 SEC. 3308.3. VERTICAL SAFETY NETTING REQUIREMENTS - NOTED AT TIME OF INSPECTION OBSERVED VERTICAL SAFETY NETTING NOT ... $1,600 $0 Jan 14, 2013
Sep 11, 2012 34987543X RESOLVE CLASS - 1 SEC. 3303.12 NO(ELEVATOR) IN READINESS - AT TIME OF INSPECTION,OBSERVED BUILDING ERECTED OVER 75 IN HEIGHT - NO ELEVA... $1,600 $0 Dec 3, 2012
Sep 11, 2012 34987541M RESOLVE CLASS - 1 FAILURE TO PROVIDE CONCRETE SITE SAFETY MANAGER ON SITE - AT TIME OF INSPECTION OBSERVED BUILDING ERECTED TO 8TH FLOO... $1,200 $0 Dec 3, 2012
Sep 11, 2012 34987542Y RESOLVE CLASS - 1 SEC. 3308.13 HORIZONTAL SAFETY NETTING NOT PROVIDED - AT TIME OF INSPECTION OBSERVED HORIZONTAL NETS MISSING ON 4TH A... $1,600 $0 Dec 3, 2012
Sep 11, 2012 34987544H RESOLVE CLASS - 1 SEC. 1906.6 RESHORES NOT SECURED - AT TIME OF INSPECTION - OBSERVED RESHOES AT (PERMITS) OF BUILDING ON 7TH FLOOR NOT... $1,600 $0 Dec 3, 2012
Jul 31, 2012 34980761M RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS-PARTIAL STOP WORK ORDER ISSUED PURSUA... $2,400 $0 Oct 25, 2012
Jul 31, 2012 34980759N RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & AMENDMENTS-PARTIAL STOP WORK ORDER ISSUED PURSUANT TO 28-2... $1,000 $0 Oct 25, 2012
Jul 31, 2012 34980758L RESOLVE CLASS - 1 SEC. 3309.1 FAILURE TO PROVIDE CONTINUOUS PROTECTION FOR ADJACENT PROPERTY DURING CONSTRUCTION-PARTIAL STOP WORK ORDE... $1,600 $0 Oct 24, 2012
Jul 31, 2012 34980760K RESOLVE CLASS - 2 SEC. 3301.7 DESIGN REQUIRED BY THE CHAPTER 33 PARTIAL STOP WORK ORDER ISSUED PURSUANT TO 28-207.2 AS (1) POSTED AT PR... $400 $0 Sep 17, 2012
Dec 13, 2011 34934850R RESOLVE CLASS - 2 EXPIRED PERMIT. NOTED PERMIT # 310071294 FN EXPIRED ON 10/19/10.REMEDYRENEW PERMIT. $400 $0 Mar 5, 2012
May 3, 2011 34910636J RESOLVE CLASS - 2 SEC. 105.8 EXPIRED PERMITS FOR TEMPORARY CONSTRUCTION EQUIPMENT NOTED: UPON INSPECTION FENCE PERMIT EXPIRED. PERMIT #... $800 $0 Jun 20, 2011
Mar 24, 2011 34906000M RESOLVE CLASS - 2 WPRK W/O A PERMIT. EXPIRED PERMIT. CONSTRUCTION FENCE ERECTED IN FRONT OF PRPERTY PERMIT #310092869 EXPIRED 2/25/09. ... $4,000 $0 May 9, 2011
Mar 17, 2011 34895579J RESOLVE CLASS - 2 FAILED TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTE:CONSTRUCTION FENCE IS COLLAPSED CAUSING 2' X8' GAP IN FENCE BTW... $2,500 $0 May 2, 2011
Oct 27, 2010 34874512M RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. NOTE: AT CENTER OF SITE,A POOL OF STAGNANT WATER ... $4,000 $0 Dec 20, 2010
Oct 27, 2010 34874513Y RESOLVE CLASS - 3 WORK W.O PERMIT. NOTED: CONST FENCE ERECTED AT PERIMETER OF SITE NO VALID PERMIT ISSUED. PERMIT 310071294 EXP 10/19/0... $500 $0 Dec 20, 2010
Mar 16, 2010 34769151L RESOLVE CLASS - 1 3309.6MISC VIO FAILURE TO ADEQUATELY INVESTIGATE & CONTROL THE INFLOW OF GROUND WATER INTO EXCAVATION SITE &/PROVIDE ... $8,000 $0 May 10, 2010
Mar 16, 2010 34769150J RESOLVE CLASS - 1 3303.1MISC VIO FAILURE TO PROVIDE A SOLID 8 FT HIGH CONSTRUCTION FENCE WHERE CONST & EXCAVATION OPERATIONS HAVE BEEN ... $8,000 $0 May 10, 2010
Oct 20, 2009 34796874Z RESOLVE CLASS - 2 WORK W/O A PERMIT. EXPIRED PERMIT NOTED: 8FT HEIGHT PLYWOOD CONSTRUCTION FENCE ERECTED WITH PERMIT #302395824 EXPIRED... $4,000 $0 Sep 13, 2010
Jul 31, 2009 34796481H RESOLVE CLASS - 2 SEC BC3304.8 MISC VIOLATIONS EXCAVATION NOT ADEQUATELY DRAINED OF RAIN AND OR SUBSURFACE WATER NOTED CONTRACTOR OWNER... $0 $0 Sep 21, 2009
Mar 3, 2008 34633151Z RESOLVE Hazardous FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY DEMOLITION OPERATIONS. UPON INSPECTION DEMO WORK ON SITE WAS IN PR... $1,500 $0 Jun 29, 2009