Skip to content

Maintenance code violations

346-348 8 Street, Brooklyn • Block 01005 • Lot 0042

111 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
Apr 30, 2026 A NOV SENT OUT (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... Aug 3, 2026
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Apr 3, 2024 A NOV SENT OUT (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... Jul 7, 2024
Feb 20, 2024 C NOV SENT OUT § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... 2 Mar 5, 2024
Feb 20, 2024 C VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF IRON HOOK PERMANENTLY IN... Mar 5, 2024
Feb 20, 2024 B NOV SENT OUT § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, ... 2 Mar 26, 2024
Feb 20, 2024 C VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF KICK DOWN DOOR STOP PERM... Mar 5, 2024
Feb 20, 2024 B NOV SENT OUT § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... 2 Mar 26, 2024
Feb 20, 2024 C NOV SENT OUT § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd... 2 Feb 19, 2024
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Feb 18, 2022 A NOV SENT OUT (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... May 24, 2022
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Apr 5, 2021 A NOV SENT OUT (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... Jul 9, 2021
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Jul 13, 2016 A NOV SENT OUT SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN T... 2 Oct 16, 2016
Jul 13, 2016 A NOV SENT OUT SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS IN THE 2nd ROOM ... 2 Oct 16, 2016
Jul 13, 2016 B NOV SENT OUT SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... 2 Aug 17, 2016
Jul 13, 2016 A NOV SENT OUT SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW FRAMES IN THE 1st ROOM FROM NORTH LOCATED AT ... 2 Oct 16, 2016
Jul 13, 2016 B NOV SENT OUT SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING IN THE 2nd ROOM FROM NORTH LOC... 2 Aug 17, 2016
Jul 13, 2016 A NOV SENT OUT SECTION 27-2013 ADM CODE REMOVE THE DIRTY AND/OR LOOSE PAPER AND REPAPER OR PAINT TO THE SATISFACTION OF THIS DEPARTM... 2 Oct 16, 2016
Jul 13, 2016 B NOV SENT OUT SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR PIPE IN THE KITCHEN LOCATED... 2 Aug 17, 2016
Jul 13, 2016 A NOV SENT OUT SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE NORTH WINDOW FRAME IN THE 2nd ROOM FROM NORTH LOCATE... 2 Oct 16, 2016
Jul 13, 2016 B NOV SENT OUT SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... 2 Aug 17, 2016
Jul 13, 2016 B NOV SENT OUT SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING IN THE PRIVATE HALLWAY LOCATED... 2 Aug 17, 2016
I VIOLATION DISMISSED SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CO...
May 22, 2008 C NOT COMPLIED WITH D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... May 28, 2008
May 22, 2008 B NOT COMPLIED WITH D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPE... Jun 26, 2008
May 22, 2008 B NOT COMPLIED WITH D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPE... Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT ROTTED AND WATER SOAKED CLG JOISTS CELLAR CE... Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRES 4 STY SOUTHEAST APT 8 THROUGHOUT. , S... 8 Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 4 STY NORTH... 8 Jun 26, 2008
May 22, 2008 A FIRST NO ACCESS TO RE- INSPECT VIOLATION SECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE CEILING 4 STY NORTHEAST APT 8 BATHROOM. , SECTION '' '' 8 Aug 25, 2008
May 22, 2008 A FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE REFIT DOOR AT BOTTOM OF CELLAR STAIRS. Aug 25, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER 4 STY NORTH APT ALL ROOMS. Jun 26, 2008
May 22, 2008 B NOT COMPLIED WITH D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPE... Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER 4 STY NORTHEAST APT 8 1 ROOM FROM KITCHEN. , S... 8 Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 4 STY... 8 Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CEILING 4 STY NORTHEAST APT 8 KITCHE... 8 Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 4 STY APT 8... 8 Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG KITCHEN 4TH STY... 8 Jun 26, 2008
May 22, 2008 A NOT COMPLIED WITH D26-22.03 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND T... Aug 25, 2008
May 22, 2008 A FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 4 STY NORTHEAST APT ... 8 Aug 25, 2008
May 22, 2008 A FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01 ADM CODE REFIT DOOR 1ST STY PUB HALL TO CELLAR. Aug 25, 2008
May 22, 2008 B NOT COMPLIED WITH D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPE... Jun 26, 2008
May 22, 2008 A FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 4 STY APT 8 KITCHEN.... 8 Aug 25, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 3 STY NORTHEAST APT 5. , SECTION '' '' 5 Jun 26, 2008
May 22, 2008 B FIRST NO ACCESS TO RE- INSPECT VIOLATION SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING 4 STY NORTH ... 8 Jun 26, 2008
May 22, 2008 A FIRST NO ACCESS TO RE- INSPECT VIOLATION SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITIO... 8 Aug 25, 2008