111 15 Street, Brooklyn • Block 01040 • Lot 0064

17 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 12, 2024 39132770Y RESOLVE CLASS - 2 FAILURE TO PROVIDE KEY FOR ACCESS TO HEATING SYSTEM AS PER HMC-27-2033.CALLED PHONE NUMBER OF DESIGNATED PERSON POSTE... $0 $0 Feb 19, 2025
Feb 3, 2023 39078987K RESOLVE CLASS - 3 FAILURE TO PROVIDE ACCESS TO BLR FOR INSP HMC27-2033; PREVIOUS CURED VIO ISSUED 39071462X/ I RANG BELL#6 THEY SAID DO... $250 $0 Apr 12, 2023
Nov 21, 2022 39074210N RESOLVE CLASS - 3 BOILER WATER LEVEL SURGINGÝCAUSING ON+OFF CONDITION¨ AND NOT BUILDING STEAM PRESSURE TO HEAT UPPER FLOORS/WIRES EXPOS... $0 $0 Jan 25, 2023
Oct 5, 2022 39071462X RESOLVE CLASS - 3 FAILURE TO PROVIDE ACCESS TO BOILER FOR INSPECTION HMC27-2033/I CALLED THE # DISPLAYED IN LOBBY MESSAGE SAID NOT IN S... $0 $0 Feb 8, 2023
Apr 6, 2022 39059632H RESOLVE CLASS - 3 COLD WATER MAIN IN BOILER ROOM IS LEAKING/BOILER ROOM DOOR DOES NOT SELF CLOSE INTO THE FRAME;CORRECT VIOLATION AND S... $0 $0 Aug 10, 2022
Nov 9, 2021 39050871Y RESOLVE CLASS - 2 STORAGE AT GAS METERS;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION $312 $0 Mar 16, 2022
Nov 15, 2019 39012974J RESOLVE CLASS - 1 I OBSERVED IN THE CELLAR AREA NEWLY INSTALLED GAS PIPING FOR 2 NEW HOT WATER HEATERS, AND NEWLY INSTALLED GAS PIPING ... $0 $0 Mar 11, 2021
Nov 15, 2019 39012960Z RESOLVE CLASS - 2 WATER LEAK BACK FLOW, STEAM LEAK HEADER, EXPOSED WIRING, LOW WATER CUTOFF NOT INSTALLED PROPERLY, HOLES IN CEILING& D... $312 $0 Oct 19, 2020
Nov 15, 2019 39012976N RESOLVE CLASS - 1 I OBSERVED IN THE CELLAR AREA, GAS BEING SUPPLIED 2 NEW HOT WATER HEATERS, WITHOUT ANY INSPECTIONS AND CERTIFICATION ... $0 $0 Mar 11, 2021
Nov 15, 2019 39012973H RESOLVE CLASS - 1 I OBSERVED IN THE CELLAR AREA ON THE GAS LINE FOR THE TWO NEW HOT WATER HEATERS A BUSHING INSTALLED ON THE GAS LINE W... $0 $0 Mar 11, 2021
Nov 15, 2019 39012975L RESOLVE CLASS - 1 I OBSERVED IN THE CELLAR AREA NEWLY INSTALLED GAS PIPING FOR 2 NEW HOT WATER HEATERS AND NEWLY INSTALLED GAS PIPING I... $0 $0 Mar 11, 2021
Nov 23, 2015 32075890X RESOLVE CLASS - 2 B254,6A,15,25A,34B,44A,48A,50,50A. 50-WATER FEED DIRECT INTO CASTIRONBOILER; 50A-FIRE CHAMBER,SEVERAL FIRE BRICK HAVE... $500 $0 Mar 28, 2016
Apr 25, 2015 32075244L RESOLVE CLASS - 2 B254,38,32,15,16,34B,50A,50B,50C. 50A-FIRE CHAMBER BRICK COLLAPSED; 50B-FLUE PIPE DEFECTIVE; 50C-BURNER MOUNT NOT SEA... $250 $0 Jun 15, 2015
Dec 20, 2014 32074883N RESOLVE CLASS - 2 B254,38,32A,15,16,25A,25B,50A,50B,50C,50D. 50A-BACK FLOW PREVENTOR LEAKING; 50B-FIRE CHAMBER BRICK COLLAPSED; 50C-FLU... $500 $0 Feb 9, 2015
Nov 6, 2013 35064982Z RESOLVE CLASS - 3 FAILURE TO MAINTAIN BLDGS WALLS OR APPURTENANCES - AT EXPOSURE 1 MAIN ENTRY DOOR STONE MASONRY CANOPY APPROX 2'DEPTH ... $230 $0 Dec 23, 2013
Mar 27, 1997 34151915H RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR OF THE BUILDING DEFECT IS: BROKEN CRACKEDMASONRY DEFECT IS: BROKEN CRACKED MASONRY CANOP... $175 $0 Jul 7, 1997
Mar 15, 1993 34088823L RESOLVE Non-Hazardous FAILURE TO MAINTAIN: VERTICAL CRACK IN CONCRETE AWNING ABOVE MAIN ENTRANCE DOOR. APPROX 1/8" WIDE BY 3' LONG. REMEDY:... $0 $0 May 17, 1993