ECB violations
16 Street, Brooklyn • Block 01053 • Lot 0020
18 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 16, 2026 | 35726437N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ASNOTED: AT TIME OF INSPECTION AT A JOBSITE OF A ... | $2,500 | $2,500 | Aug 26, 2026 |
| May 21, 2026 | 35726285N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN-PARKING STRUCTURE IN A SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION OF MY INSPECTION ON A OCCU... | $1,250 | $1,250 | Feb 22, 2027 |
| May 7, 2026 | 39553866Y | ACTIVE | CLASS - 1 | TIME OF INSPECTION I OBSERVED CONSTRUCTION ACTIVITIES EXCAVATION OF DIRT WITH HEAVY EQUIPMENT ON SITE IN PROXIMITY TO... | $5,000 | $5,000 | Mar 5, 2027 |
| Feb 8, 2026 | 39550106H | RESOLVE | CLASS - 2 | BLIND SPOT MIRROR. BC 3307.2.6. REQUIREMENTS FOR TEMP. WALKWAY-OBSERVED NO BLIND SPOT MIRRORS ON THE CORNER OF FULLY ... | $2,500 | $2,500 | Apr 15, 2026 |
| Feb 8, 2026 | 39550105X | RESOLVE | CLASS - 2 | ATOI AT 5 STORY NB. SITE CLOSED I OBSERVED TEMPORARY PUBLIC WALKWAY WAS FULLY ENCLOSED WITH BOTH SIDES CONTRARY TO BC... | $2,400 | $2,400 | Apr 15, 2026 |
| Feb 8, 2026 | 39550104Y | ACTIVE | CLASS - 2 | ATOI OF A 5-STORY NEW BUILDING , BUILDING FOOTPRINT 32408 SQUARE FEET. SITE CLOSED AND THERE WAS NO CONSTRUCTION ACTI... | $2,500 | $2,500 | Apr 15, 2026 |
| Oct 28, 2025 | 39165030J | RESOLVE | CLASS - 1 | A TIME OF INSPECTION OBSERVE NEW 5 STORY BUILDING ERECTED UNDER JOB NUMBER B00656247 HOUSEKEEPING INADEQUATE EXCESSIV... | $2,500 | $2,500 | Feb 27, 2026 |
| Jan 29, 2025 | 39536415K | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED STREET OPERATION FOR CONCRETE POUR BEING PERFORMED UPON REQUEST FOR APPROVED SITE SAFE... | $5,000 | $0 | Apr 14, 2026 |
| Jan 29, 2025 | 39536414Z | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, A WORKER WAS OBSERVED CLOSING THE STREET FOR CONCRETE POURING ON THE 5TH FLOOR. UPON REQUE... | $0 | $0 | Apr 9, 2025 |
| Jan 29, 2025 | 39536402L | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, WORKERS WERE OBSERVED POURING AND FORMING CONCRETE ON THE 5TH FLOOR DECK, IN VIOLATION OF ... | $5,000 | $0 | Oct 6, 2025 |
| Jan 29, 2025 | 39536412P | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, THE STREET WAS OBSERVED CLOSED WITHOUT A VALID DOT PERMIT, AND CONCRETE OPERATIONS WERE ON... | $5,000 | $0 | Oct 6, 2025 |
| Jan 14, 2025 | 39535957K | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION PROPOSED 5-STORY NEW BUILDING, 50 FT MAIN STRUCTURE HEIGHT PLUS BULKHEAD, OBSERVED ACTIVE CONST... | $10,000 | $10,000 | Oct 5, 2026 |
| Jan 14, 2025 | 39536002M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION PROPOSED 5-STORY NEW BUILDING WITH APPROVED HEIGHT OF 83 FEET AT BULKHEAD OBSERVED ACTIVE CONST... | $10,000 | $10,000 | Oct 5, 2026 |
| Dec 3, 2024 | 39534857Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE OVERHEAD PROTECTION. AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING UNDER CONSTRUCTION CUR... | $10,000 | $0 | Aug 19, 2025 |
| Dec 3, 2024 | 39534888L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE ROOF PROTECTION. AT THE TIME OF MY INSPECTION OF A 5 STORY BUILDING CURRENTLY AT 3RD FLOOR LEVEL, ... | $5,000 | $0 | Sep 12, 2025 |
| Dec 3, 2024 | 39534858K | RESOLVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OF A ACTIVE 5 STORY NEW BUILDING UNDER CONSTRUCTION CURRENTLY AT 3RD FLOOR LEVEL , I OBS... | $10,000 | $0 | Aug 19, 2025 |
| Nov 22, 2024 | 35686934K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE ... | $1,250 | $0 | Sep 12, 2025 |
| Sep 17, 2024 | 35684072R | RESOLVE | CLASS - 1 | NO SITE-SPECIFIC FORMWORK DESIGN DRAWINGS PRESENT PER 3301.7. AS NOTEDAT TIME OF MY INSPECTION ON AN ACTIVE CONSTRUCT... | $2,500 | $0 | Nov 27, 2024 |