ECB violations
287-291 Prospect Avenue, Brooklyn • Block 01053 • Lot 0070
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 21, 2026 | 39185483K | RESOLVE | CLASS - 2 | 1) SEAL HOIST MACHINE OIL LEAK. 2) ADJUST ALL DESIGNATED FLOOR LANDINGS C-8. 3) DOOR OPERATOR DOES NOT OPEN CAR DOOR/... | $0 | $0 | Jul 1, 2026 |
| Dec 18, 2025 | 35683266K | ACTIVE | CLASS - 1 | WORK WITHOUT A PERMIT: NOTE OBSERVED AT TIME OF INSPECTION NEW ELECTRICAL SERVICE PANEL INSTALLED WHILE EXISTING PERM... | $2,500 | $2,500 | Sep 11, 2026 |
| Dec 18, 2025 | 35683265Z | ACTIVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK: OBSERVED DURING INSPECTION, EVIDENCE OF UNLAWFULLY CONTINUED WORK AT THE CAPTION LOCATION ... | $25,000 | $25,000 | Sep 11, 2026 |
| Dec 1, 2025 | 39168694X | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS ... | $1,250 | $1,250 | Feb 4, 2026 |
| May 15, 2025 | 39148079X | ACTIVE | CLASS - 1 | FAILED TO OBTAIN PERMIT FOR SUMMONS #35680659H, COMPLY WITH COMMISSIONER'S ORDER | $2,500 | $0 | Jul 23, 2025 |
| Apr 8, 2025 | 37034871L | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $2,500 | $2,500 | Jan 27, 2026 |
| Jul 30, 2024 | 39120294Y | RESOLVE | CLASS - 2 | CLASS 2: DOOR OPERATOR MALFUNCTIONING. DOOR DOES NOT FULLY OPEN & GETS STUCK. BOARD IS MALFUNCTION REPLACE WITH NEW B... | $0 | $0 | Oct 9, 2024 |
| May 9, 2024 | 39113894M | RESOLVE | CLASS - 2 | INOPERATIVE PHONE. PERFORM PREVENTIVE MAINTENANCE ON ZONE LOCK RESTRICTOR TO ENSURE PROPER OPERATION. REPLACE WORN GI... | $312 | $312 | Jun 17, 2026 |
| Mar 8, 2024 | 39108182H | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED CONTRUCTION ACTIVITY ON PROGRESS AT 5TH FLOOR APT. 5D CONTRARY TO PSWO# 35680659H ISSU... | $5,000 | $0 | Sep 19, 2024 |
| Jan 31, 2024 | 35680659H | ACTIVE | CLASS - 1 | WORK WITHOUT PERMIT:AT TIME OF INSPECTION OBSERVED 5 WORKERS ON CONSTRUCTION ACTIVITY AT 5TH FLOOR IN APT.5D THE WORK... | $1,250 | $0 | Aug 20, 2024 |
| Nov 24, 2023 | 39100010P | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING PROPERLY. THIS SAFETY DEVICE PREVENTS THE CAB DOOR FROM OPENING IN BETWEEN FLOORS WH... | $1,250 | $1,250 | Mar 4, 2024 |
| Nov 24, 2023 | 39100011R | RESOLVE | CLASS - 2 | HATCH DOOR IN LOBBY MISSING GIBB, NEED TO PROVIDE NEW GIBB. SIGHT GUARD ON LOBBY HATCH DOOR IS LOOSE, NEED TO PROPERL... | $0 | $0 | Apr 9, 2024 |
| Dec 20, 2017 | 35265010P | RESOLVE | CLASS - 2 | REMOVAL OF SAFETY MEASURES,SUCH AS SIDEWALK SHED'S W/OUT DEPT APPROVAL.@THE TIME OF INSP BLDG FACADE WAS STILL DESIGN... | $800 | $0 | Apr 18, 2018 |
| Mar 30, 2017 | 35210703J | RESOLVE | CLASS - 1 | FAILURE TO TAKE PROVIDE SAFETY MEASURE/SUCH AS SIDEWALK SHEDS,FENCE,ETC.WHERE REQUIRED TO PROTECT AND SECURE PUBLIC S... | $2,400 | $0 | May 15, 2017 |
| Nov 7, 2016 | 37001618R | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 1... | $0 | $0 | Mar 13, 2017 |
| Aug 17, 2016 | 35202806M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER LACK OF A SYSTEMOF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 9... | $1,000 | $0 | Dec 14, 2016 |
| Aug 17, 2016 | 35202808X | RESOLVE | CLASS - 1 | BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID C OF O NOTED:NB JOB# 300637951(NO SIGN OFF)TEMPORARY C OF O EXPIRED BUI... | $0 | $0 | Dec 14, 2016 |
| Aug 17, 2016 | 35202807Y | RESOLVE | CLASS - 1 | BC907.2.8 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER FAILURE TO PROVIDE FIRE ALARM SYSTEM IN TRANSIENT OCC... | $1,600 | $0 | Dec 14, 2016 |
| Aug 17, 2016 | 35202805K | RESOLVE | CLASS - 2 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSES DEPT OF BUILDINGS RECORDS INDICATES R... | $800 | $0 | Nov 16, 2016 |
| Nov 23, 2015 | 38239383H | RESOLVE | CLASS - 2 | 02X10,40M07. 02X-CAR OUTSIDE COMMUNICATIONS; 40M-BI-LEVEL MACH ROOM MISSING EMERG STOP SWITCH AT MAC LEVEL. | $500 | $0 | Jan 11, 2016 |
| Jun 2, 2015 | 35132048L | RESOLVE | CLASS - 2 | NOTIFICATION.NOTED:@TIME OF INSP THERE WAS NO HANGING EQUIPMENT/C-HOOKS ON SITE.FAILED TO NOTIFY THE DEPT 24-48 HRS P... | $830 | $0 | Jul 20, 2015 |
| Jan 26, 2015 | 36027150J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $800 | $0 | Jun 29, 2015 |
| Jul 31, 2006 | 38160309H | RESOLVE | Non-Hazardous | 15M07/59Q03/83L10/60T07 15)CERTIFICATE FRAME MISSING. 59)MOTOR ROOM LIGHTS UNGUARDED. 83)EMERGENCY PHONE NOT WORKING.... | $2,500 | $0 | Sep 18, 2006 |
| Apr 28, 1998 | 34176180R | RESOLVE | Non-Hazardous | DEPARTMENT OF TRANSPORTATION PERMIT FOR SIDEWALK CLOSING NOT POSTED, SIDEWALK IS APPROX 15 FEET WIDE, APPROX 9' FEET ... | $200 | $0 | Sep 21, 1998 |