Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 8, 2026 39550096N RESOLVE CLASS - 1 BC3307.4 OBSERVED STORAGE ZONE IN THE STREET WITH YODOK'S SCATTERED INTO ACTIVE VEHICULAR LANES, DISLODGED/ EXPOSED M... $2,400 $0 Apr 15, 2026
Dec 20, 2025 39548185M RESOLVE CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED FIXED OUTRIGGERS BEAM SUSPENDED SCAFFOLD INSTALLED AT ALL EXPOSURE, AFTER REVIE... $0 $0 Feb 25, 2026
Dec 20, 2025 39548175Z RESOLVE CLASS - 2 AT THE TIME OF INSPECTION, SIDEWALK SHED INSTALLED AT EXPOSURE 1, I OBSERVED ILLUMINATED LIGHTING WRAPPED AROUND BOTH... $0 $0 Feb 25, 2026
Dec 20, 2025 39548182R RESOLVE CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED SUSPENDED SCAFFOLD ERECTED AT THE CORNER OF EXPOSURE 1 & 2, THAT IS NOT SHOWN O... $0 $0 Feb 25, 2026
Sep 3, 2025 35718214X RESOLVE CLASS - 1 UNLAWFULLY CONTINUE WORK WHILE ON NOTICE OF A STOP WORK ORDER.AS NOTEDAT THE ABOVE ACTIVE JOBSITE OBSERVED WORK ADJOI... $25,000 $25,000 Feb 18, 2027
Aug 8, 2025 35693949Z ACTIVE CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE 19 STORY N... $10,000 $10,000 Nov 24, 2026
Jul 12, 2025 39542292K RESOLVE CLASS - 2 BC3303.3 19 STORY NEW BUILDING, BUILDING APPROXIMATELY 15669 SQUARE FEET. NO TCO, MEET WITH CONCIERGE INADEQUATE/UNQU... $2,500 $2,500 Jun 16, 2026
Jul 11, 2025 35693971P RESOLVE CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE C... $1,250 $1,250 Jun 16, 2026
Jul 11, 2025 35716923J RESOLVE CLASS - 1 WORK WITHOUT A PERMIT. AS NOTED AT TIME OF MY INSPECTION AT AN ACTIVE JOB SITE OBSERVED STAIRS AND FOUNDATION FROM TH... $1,250 $1,250 Jun 16, 2026
Jul 5, 2025 39542008Y RESOLVE CLASS - 2 NOTE: AT TIME OF INSPECTION, I OBSERVED YODOCK SYSTEM IN PLACE WITH CHAIN LINK FENCE MOUNTED ON TOP WITH MISSING INTE... $0 $0 Apr 16, 2026
Jul 5, 2025 39542007M RESOLVE CLASS - 2 ATOI OF A 19-STORY NB 15,669 SQ FT. SITE WAS CLOSED WITH NO CONSTRUCTION ACTIVITY. UPON SHOUTING AROUND THE PERIMETER... $2,500 $2,500 Apr 16, 2026
May 31, 2025 39540845M RESOLVE CLASS - 2 19 STORY NB WITH A BUILDING FOOTPRINT(SQ. FT.)15669 SITE CLOSED NO CONSTRUCTION ACTIVITY OBSERVED. WALKED AROUND PERI... $2,500 $2,500 Dec 17, 2026
May 29, 2025 39540805H RESOLVE CLASS - 2 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING I OBSERVED FOAM AND STUCCO OPERATION IN PROGRESS AT EXPOSURE 3... $5,000 $5,000 Sep 9, 2026
May 24, 2025 39540641K RESOLVE CLASS - 2 NO WATCH PERSON AT THE TIME OF INSPECTION OF A 19 STORY BUILDING UNDER CONSTRUCTION APPROXIMATELY 24,000 SQUARE FEET ... $0 $0 Feb 9, 2026
Jan 8, 2025 39535755M RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING, I OBSERVED CONSTRUCTION WORK IN PROGRESS, UPON REVIEW OF THE... $5,000 $5,000 Jun 1, 2026
Jan 8, 2025 39535765X RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING, I OBSERVED CONSTRUCTION WORK IN PROGRESS, UPON REQUEST FOR S... $10,000 $0 Jun 1, 2026
Jan 8, 2025 39535764Y RESOLVE CLASS - 1 BC 3301.1.2 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING, I OBSERVED CONSTRUCTION WORK IN PROGRESS, UPON R... $0 $0 Jun 1, 2026
Jan 7, 2025 39535704M RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING TOP OFF. I OBSERVED CONSTRUCTION WORK IN PROGRESS AND AT THE ... $0 $0 Jun 1, 2026
Jan 7, 2025 39535706X RESOLVE CLASS - 1 BC 3310.5.1 AT THE TIME OF MY INSPECTION OF A 17 STORY BUILDING, UPON REVIEW OF THE SITE SAFETY MANAGER LOG BOOK, SIT... $0 $0 Jun 1, 2026
Sep 19, 2024 39532557H RESOLVE CLASS - 2 BC 3307.4.7 AT TIME OF INSPECTION OBSERVED: AT EXPOSURE# 3 INADEQUATE STORAGE ZONE AREA CONTRARY TO SITE SAFETY PLAN,... $0 $0 Jul 1, 2025
Sep 10, 2024 39124474J RESOLVE CLASS - 1 AT TIME OF INSPECTION OBSERVED AT TOWER WHICH AT PACIFIC STREET (NORTH EAST SIDE) EXP#4 SIDE NO TOE BOARD AND NETTING... $0 $0 May 20, 2025
Sep 4, 2024 35684065Z RESOLVE CLASS - 1 NO SITE-SPECIFIC FORMWORK DESIGN DRAWINGS PRESENT PER 3301.7.AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION... $2,500 $0 Nov 13, 2024
Aug 20, 2024 35683759Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENT REQUIRED BC CHAPTER 33. AS NOTED AT TIME OF INSPECTION OBSERVED THE REMO... $1,250 $0 Mar 18, 2025
Jul 11, 2024 39530465L RESOLVE CLASS - 1 CARPENTER FELL THROUGH THE HOLE, AND THE AMBULANCE WAS CALLED. UPON REVIEW OF THE DEPARTMENT RECORDS IT WAS REVEALED ... $0 $0 Nov 6, 2024
May 25, 2024 39528985M RESOLVE CLASS - 1 FAILURE TO PROVIDE WATCHPERSON-BC-3303.3.ATOI AT THE PROPOSED 17-STORY NB NO CONSTRUCTION ACTIVITIES, I OBSERVED THAT... $2,500 $0 Sep 11, 2024
Apr 15, 2024 39527535K RESOLVE CLASS - 2 AT TIME OF INSPECTION, NO MIRRORS WERE PROVIDED/INSTALLED (AS REQUIRED PER BC 3307.2.6.3) ON THE CORNERS OF SIDEWALK ... $625 $0 Oct 27, 2025
Apr 15, 2024 39527536M RESOLVE CLASS - 1 OBSERVED INADEQUATE TEMPORARY GUARDRAIL SYSTEMS NEAR EDGE OF SLAB ON 1ST, 2ND AND 3RD FLOORS (ALL EXPOSURES) AND AROU... $5,000 $0 Oct 27, 2025
Apr 7, 2024 39527238Y RESOLVE CLASS - 2 BC 3309.10 PROTECTION OF ROOFS. OBSERVED IN ADEQUATE ROOF PROTECTION FOR ADJACENT BUILDING EXP#2, OBSERVED ROOF PROTE... $0 $0 Nov 12, 2024
Mar 24, 2024 39526757L RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY BUILDING AT 3 FLOOR DECKING LEVEL, SITE CLOSED AND THERE WERE NO CONSTRUCT... $5,000 $0 May 22, 2025
Mar 21, 2024 39526688R RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY BUILDING, I OBSERVED AT EXPOSURE #2 ADJACENT PROPERTY AT 1039 PACIFIC STRE... $2,500 $0 May 22, 2025
Mar 21, 2024 39526687P RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT 3 FLOOR DECKING, I OBSERVED CONCRETE TRUCK WITH OUT RIGGER... $1,250 $0 May 22, 2025
Mar 21, 2024 39526686N RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT 3 FLOOR DECKING, I OBSERVED SIDEWALK SHED IN PROCESS OF IN... $10,000 $0 May 22, 2025
Mar 21, 2024 39526690X RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT 3 FLOOR DECKING, I OBSERVED SIDEWALK SHED IN PROCESS OF IN... $5,000 $0 May 22, 2025
Mar 21, 2024 39526692J RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT SUPER STRUCTURE PHASE 3 STORY, UPON REVIEW OF THE SITE SAF... $2,500 $0 May 22, 2025
Sep 13, 2023 39521659P RESOLVE CLASS - 2 AT THE TIME OF MY INSPECTION, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 WITH A VALID PERMIT DATE: 09-30-2023 A... $0 $0 Oct 7, 2024
Oct 8, 2021 39049040P RESOLVE CLASS - 2 SAFETY VALVE DISCHARGE NOT PIPED DOWN/SMALLER FLUE NOT ABOVE LARGER FLUE INTO CHIMNEY/NO DOOR AT BASE OF CHIMNEY/WATE... $655 $0 Feb 9, 2022