| Aug 14, 2020 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 4 | Sep 18, 2020 |
| Aug 14, 2020 | C | NOT COMPLIED WITH | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STOR... | 4 | Sep 9, 2020 |
| Aug 14, 2020 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY... | 4 | Sep 18, 2020 |
| Aug 14, 2020 | A | VIOLATION CLOSED | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CERAMIC TILE SURFACE AND GROUTED JOINTS OF VISI... | 4 | Nov 17, 2020 |
| Mar 16, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CERAMIC TILES AT EAST (APPROX... | 4 | Aug 18, 2020 |
| Mar 16, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLETS AT EAST WALL IN THE 3rd ROOM FROM EAST ... | 4 | Apr 20, 2020 |
| Mar 16, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM AT NORTH WALL IN THE FOYER LOCATED AT APT 4, 4th ... | 4 | Aug 18, 2020 |
| Mar 16, 2020 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 4, 4th STORY, 1st... | 4 | Apr 6, 2020 |
| Mar 16, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOODEN HANDRAIL AT STAIRS LEADING TO 2ND STORY PUBLIC HALL | — | Apr 20, 2020 |
| Mar 16, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLETS AT WEST WALL IN THE KITCHEN LOCATED AT ... | 4 | Apr 20, 2020 |
| Mar 13, 2020 | C | NOT COMPLIED WITH | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4 | Apr 10, 2020 |
| Dec 20, 2019 | C | NOT COMPLIED WITH | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STOR... | 4 | Jan 10, 2020 |
| Dec 20, 2019 | C | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 4 | Dec 28, 2019 |
| Dec 20, 2019 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AT PUBLIC HALL, 4th STORY | — | Jan 24, 2020 |
| Dec 20, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE OF 130 ... | 4 | Dec 28, 2019 |
| Nov 14, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, ... | 4 | Dec 19, 2018 |
| Nov 14, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER SASH WINDOW 2ND FROM NORTH AT EAST IN... | 4 | Nov 22, 2018 |
| Nov 14, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW 2ND FROM NORTH AT EAS... | 4 | Dec 19, 2018 |
| Nov 14, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 4 | Dec 19, 2018 |
| Nov 14, 2018 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4 | Dec 12, 2018 |
| Nov 14, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES AT SCUTTLE RECESS AT PUBLIC HALL, 4... | — | Dec 19, 2018 |
| Nov 14, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT FRONT ENTRANCE OF BUILDING , 1st STORY | — | Dec 19, 2018 |
| Aug 27, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Oct 1, 2018 |
| Aug 27, 2018 | A | VIOLATION CLOSED | § 27-2049 ADM CODE POST AND MAINTAIN A STREET NUMBER ON THE FRONT OF THE DWELLING PLAINLY VISIBLE FROM THE SIDEWALK. | — | Nov 30, 2018 |
| Aug 27, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT WALKING AREA IN THE 1s... | 4 | Nov 30, 2018 |
| Aug 27, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT UPPER SASH WEST WINDOW IN THE 3rd ROOM FROM EAST... | 4 | Sep 4, 2018 |
| Aug 27, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE 2nd ROOM FROM EAST L... | 4 | Oct 1, 2018 |
| Aug 27, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST AND SOUTH WALL IN THE 1st ROOM F... | 4 | Oct 1, 2018 |
| Aug 27, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT WALKING AREA IN THE KI... | 4 | Nov 30, 2018 |
| Jul 27, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY | — | Aug 31, 2018 |
| Jul 24, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SAGGING WOOD FLOOR AT WALKING AREA I... | 4 | Oct 27, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER WINDOW GLASS, CENTER SASH IN THE 1st ROOM FROM NORT... | 4 | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ELECTRICAL OUTLETS PAINTED SHUT IN THE ENTIRE APART... | 4 | Aug 22, 2018 |
| Jul 18, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AT MAIL BOX DOOR. , 1st STORY | — | Aug 22, 2018 |
| Apr 3, 2018 | B | NOV SENT OUT | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, 1st APART... | 3R | May 8, 2018 |
| Apr 2, 2018 | C | VIOLATION DISMISSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING LOCKABLE HASP WITH EYE AT FIRE ESCAPE GATE IN THE 2nd ROOM FROM... | 3R | Apr 10, 2018 |
| Apr 2, 2018 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SO... | 3R | May 7, 2018 |
| Apr 2, 2018 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3R, 3rd STORY, 1st... | 3R | May 7, 2018 |
| Apr 2, 2018 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT BATHTUB IN THE BATHROOM LOCATED AT APT 3R, ... | 3R | May 7, 2018 |
| Apr 2, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2... | 3R | May 7, 2018 |
| Mar 9, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOX IN THE VESTIBULE AT PUBLIC HALL, 1st STORY | — | Apr 13, 2018 |
| Mar 9, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORT... | 4 | Apr 13, 2018 |
| Mar 9, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS, WALLS AND TRIM... | 4 | Jun 12, 2018 |
| Mar 9, 2018 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jun 12, 2018 |
| Mar 9, 2018 | A | VIOLATION CLOSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Jun 12, 2018 |
| Mar 9, 2018 | A | VIOLATION CLOSED | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Jun 12, 2018 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Aug 8, 2017 | B | VIOLATION DISMISSED | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP... | — | Sep 12, 2017 |
| Apr 18, 2017 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCK TO CELLAR | — | Apr 26, 2017 |