Issued Class Status Violation Apartment Correct by
Aug 13, 2008 C NOV SENT OUT SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM FIXTURES, 3RD STORY APT... Aug 19, 2008
Aug 13, 2008 C NOV SENT OUT SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF DEVICE PRESENT ON CENTRAL HEATING SYSTEM--CAPABLE OF CA... Aug 19, 2008
Jul 3, 2006 C NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER AND LOWER RAIL SOUTHEAST ROOM WINDOW 2ND ... Jul 21, 2006
Jul 3, 2006 C NOV SENT OUT SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN AND BATHROOM, 2ND STORY APT. Jul 21, 2006
Jul 3, 2006 C NOV SENT OUT SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF CASCADING WATER LEAK BOILER ROOM CELLAR. Jul 21, 2006
Jul 3, 2006 C NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CEILING, 1S... Jul 21, 2006
Jul 3, 2006 C NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR PRIVATE... Jul 21, 2006
Jul 3, 2006 C NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING MARBLE NOSING AT 2ND STORY PUBLIC HALL. Jul 21, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE & CEMENT FLOO... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK KITCHEN, 2ND STORY APT 2 Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CON... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC TILES WALLS KITCHEN, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS LOWER SASH WINDOW WEST ROOM, 2ND STORY AP... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE SADDLE DOOR WEST ROOM, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES SOUTH WALL BATHROOM, 2ND STORY... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BROKEN ROTTED WOODEN CABINET WASH BASIN BATHROOM, 2ND S... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE UNHINGED DOOR BATHROOM, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING DOOR KNOB WEST ROOM, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB, BATHROOM 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING, 2N... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR, 2ND ROOM FRO... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC NOSING 2ND STORY PUBLIC HALL, STAIRS LANDING. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTRICAL LIGHT FIXTURE CEILING, 2ND STORY PUBLIC HALL. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING METAL COVER ELECTRICAL OUTLET EAST WALL WEST ROOM, 2ND STOR... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING WOODEN BASE BOARD EAST WALL WEST ROOM, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLO... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC TILES WALLS BATHROOM, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLO... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF WATER LEAK CEILING FRONT EAST ROOM, 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAKE OPERABLE SASH UPPER & LOWER WINDOW FRONT NO... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING HANDLE LATCH SET DOOR FRONT ROOM TO PUBLIC HALL, 2ND STORY ... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR SOUTH EAST RO... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING SKYLIGHT ROOF OVER PUBLIC HALL, 3RD STORY PUBLIC HALL. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES, THROUGHOUT 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTRICAL LIGHT FIXTURE CEILING, 2ND STORY PUBLIC HALL Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES NORTH WALL, 2ND STORY PUBLIC H... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT SWITCH SOUTH WALL WEST ROOM, 2N... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL SYSTEM FRONT ENTRANCE TO 2ND STORY APT 2. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL SYSTEM FRONT ENTRANCE TO 3RD STORY APT 3 Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET NORTH WALL KITCHEN, 3RD STORY APT 3. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE WASHBASIN, 3RD STORY APT 3. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE UNHINGED DOOR BATHROOM, 3RD STORY APT 3. Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WALLS SKYLIGHT RECESS BATH... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING WES... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT CERAMIC TILES WALLS ... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING METAL COVER ELECTRIC OUTLET SOUTH WALL, 2ND ROOM FROM REAR,... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS LOWER SASH WINDOW NORTH EAST ROOM, 3RD ST... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LATCH SET DOOR FRONT ROOM, 3RD STORY APT 3, TO P... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LATCH SET DOOR REAR ENTRANCE, FROM 3RD STORY APT TO PUBLIC ... Aug 19, 2006
Jul 3, 2006 B NOV SENT OUT SECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF BUILDING MATERIAL, 1ST TO 3RD STORY PUBLIC H... Aug 19, 2006