ECB violations
728 Franklin Avenue, Brooklyn • Block 01168 • Lot 0055
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 31, 2013 | 35029183Z | RESOLVE | CLASS - 2 | WORK W/O A PERMIT - WORK NOTED: 1-GROUND FLOOR LEFT SIDE - NEW STORE FRONT; 2-NEW ENTRY DOOR. | $800 | $0 | May 28, 2014 |
| Dec 11, 2012 | 34997348J | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE/MAINTAIN SUFFICIENT ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT. METER ROOM AND SER ROOM IS USED ... | $250 | $0 | Mar 18, 2013 |
| Dec 11, 2012 | 34997346X | RESOLVE | CLASS - 1 | SEC EC-215. FEEDER IS NOT OF PROPER SIZE - APT 3A. APT 3A HAS ELECTRICSTOVE AND ELECTRIC HEAT CAUSING BREAKER TO TRIP... | $0 | $0 | Mar 20, 2013 |
| Dec 11, 2012 | 34997347H | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. AN ELECT APPLICATION IS NOT ON FILE FOR 15- FEEDER AND 15 PANELS FOR ENTIRE BLDG. APP #... | $0 | $0 | Mar 20, 2013 |
| Dec 4, 2012 | 35000894X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. PROVIDE REQUIRED CORRIDOR WIDTH PER BC 1016.2;27-369. NOTED ON 2ND... | $0 | $0 | Jan 28, 2013 |
| Dec 14, 2006 | 34555525N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG DEFECT IS:IN FRONT OF BLDG @ ROOF LEVEL THE CORNICE IS IN DISREPAIR.2 SECTIONS ARE CORRDED &... | $2,500 | $0 | Jan 29, 2007 |
| Jan 6, 2003 | 34342499J | RESOLVE | Hazardous | WORK WITHOUT A PERMIT. ILLEGAL WORK NOTED: REMOVED STAIRWAY FROM 4TH FLOOR TO ROOF ALSO REMOVE BULKHEAD AND SECTION O... | $800 | $0 | Feb 2, 2004 |
| Oct 12, 2001 | 34304285R | RESOLVE | Hazardous | FAILURE TO MAINTAIN HAZARDOUS DEFECTS ARE DEFECTIVE BULK HEAD DOOR RISERS AND TREADS ARE PULLING AWAY FROM THE STRING... | $2,500 | $0 | Nov 26, 2001 |
| Aug 8, 2001 | 34300752Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING NOTED BROKEN WOODEN BEAMS AT ROOF CAUSING ENTORE WOOD FRAMED BULKHEAD TO SAGG & PROTRUDE... | $2,500 | $0 | Sep 24, 2001 |
| Aug 8, 2001 | 34299038X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING INTERIOR DEFECT IS:SAGGED AND PULLING AWAY STAIRS, FOURTH FLOOR TO ROOF.SUGGESTED REMEDY... | $2,500 | $0 | Sep 24, 2001 |
| May 17, 2001 | 34290300L | RESOLVE | Hazardous | FAILURE TO MAINTAIN NOTE:AT 4TH FLOOR LEVEL ENTIRE HALLWAY CEILING IS PITCHEDN LEANDING AND IN POSSIBLE DANGER OF COL... | $2,500 | $0 | Jul 2, 2001 |
| Apr 13, 1999 | 34210138J | RESOLVE | Non-Hazardous | FAILURE TO MAINTIAN DEFECT IS 1 EXTERIOR BRICKWORK AT REAR HAS VERTICAL CRACKS VARIOUS LOCATION 2 MORTOR JOINTS ERODE... | $10,000 | $0 | Jun 7, 1999 |
| May 12, 1998 | 34176191M | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECTS NOTED: BRICKS ARE LOOSE, BULGING, IN DANGER OF FALLING AND MORTAR... | $2,500 | $0 | Jun 29, 1998 |
| May 5, 1998 | 34176068R | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING/HAZARDOUS DEFECTS ARE/ 1)AT CELLAR WASTE LINES INSTALLED 1'APPROX ABOVE CELLAR FLOOR CRE... | $2,500 | $0 | Jun 22, 1998 |