ECB violations
611 Sterling Place, Brooklyn • Block 01168 • Lot 0085
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 7, 2017 | 35276969Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35244738P ISSUED ON 06/23/17 AND TO FI... | $800 | $0 | Jan 22, 2018 |
| Jun 23, 2017 | 35244738P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER(EGRESS).NOTED AT TIME OF INSPECTION,OBSERVED HANDICAP RAMP AT E... | $250 | $0 | Oct 18, 2017 |
| Jan 14, 2016 | 35148657N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTE: AT 3RD FLR STAIRLANDING FOUND ACCUMULATION OF STORAGE IN PUBLIC... | $6,000 | $0 | Mar 7, 2016 |
| Sep 14, 2015 | 32075734Y | RESOLVE | CLASS - 1 | B154,36,15,16,51,50A,50B,50C. 50A-FLUE PIPE NOT PROPERLY SEALED TO CHIMNEY HOLES; 50B-GAS BOILER HAS A DRY BACK; 50C-... | $2,500 | $0 | Aug 8, 2016 |
| Sep 14, 2015 | 32075735X | RESOLVE | CLASS - 1 | B154,51,50. 50A-FLUE PIPE NO PROPERLY SEALED TO CHIMNEY HOLES. | $5,000 | $0 | Feb 1, 2016 |
| Jan 28, 2015 | 35113242L | RESOLVE | CLASS - 1 | WORK W/O PERMIT @EXP#1.NOTED CONSTRUCTED WOODEN RAMP @EXP#1 FROM ENTRANCE DOOR,TURNING TO SIDEWALK.NO PERMITS FIELD.R... | $400 | $0 | Jun 15, 2015 |
| Jun 4, 2014 | 32074363J | RESOLVE | CLASS - 2 | 36,5B,15,32A 36)BURNHAM BOILER INSTALLED, KIN-12 PERMIT #320435917, EXPIRED WITHOUT SIGNOFF REMEDY:RENEW PERMIT AND G... | $2,500 | $0 | Jul 21, 2014 |
| Dec 27, 2011 | 32071615N | RESOLVE | CLASS - 2 | B254,40,47,50A,56B,36;50A-REMOVE WASTE OIL FROM BOILER ROOM,56B-CHIMNY BASE NEED TO BE CLEANED OUT. | $0 | $0 | Feb 13, 2012 |
| Mar 22, 2010 | 32068261H | RESOLVE | CLASS - 3 | 36 40 15 16 50ABCD 50A-PEEP HOLE GLASS DIRTY 50B-BOILER ROOM FIRE DOORDEFECTIVE CUTOUT 50C-NO ANTI PHYSOM VALVE ON OI... | $100 | $0 | May 17, 2010 |
| Jul 8, 2009 | 32066003X | RESOLVE | CLASS - 2 | 15,16,50,50A 50-OIL TANK VENT PIPE IS ONE INCH OUTSIDE OF BUILDING MUST BE AT LEAE 1 1/4 OR LARGER 50A- OIL TANK VENT... | $2,500 | $0 | Aug 31, 2009 |
| Nov 23, 2007 | 34612187H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG. EXCESSIVE CONSTRUCTION FLAMMABLE DEBRIS. OBSERVE IN THE FRONT YARD OF THE BLDG APPROX 5'HIG... | $180 | $0 | Jan 28, 2008 |
| Aug 15, 2006 | 32051961H | RESOLVE | Hazardous | B4B/51/32/50/50A 50-BOILER CHIMNEY NOT BEING USED. SMOKE PIPE RUNNING THRU BASEMENT WITH SINGLE WALL SMOKE PIPE & FAN... | $800 | $0 | Dec 26, 2007 |
| Apr 26, 2006 | 32048620M | RESOLVE | Hazardous | CEASE USE/B4B,51,BQ,50/ OIL FIRES BOILER BURNING W/O CHIMNEY VENTING THROUGH BASEMENT WINDOW | $5,000 | $0 | Sep 18, 2006 |
| Dec 21, 2005 | 32049010J | RESOLVE | Non-Hazardous | 21B32A/50I 3651 50A50B 50C50D 50E50F 50G50H 50A) BOILER HAD FIRE AS OFCOMPLAINT 11/29/05 BOILER WIRE DAMAGES. 50B) BO... | $800 | $0 | Mar 6, 2006 |