| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Dec 22, 2020 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO T... | — | Jan 17, 2021 |
| Dec 22, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE THE 4TH MARBLE TREAD UP FROM THE BOTTOM AT PUBLIC HALL ST... | — | Dec 28, 2020 |
| Nov 23, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER INSTALLED AT WINDOW LEADING TO THE ... | D2 | Nov 29, 2020 |
| Nov 23, 2020 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRA... | D2 | Dec 19, 2020 |
| Nov 23, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 1st ROOM FROM ... | B10 | Dec 28, 2020 |
| Nov 23, 2020 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B4, 2nd STOR... | B4 | Dec 28, 2020 |
| Nov 23, 2020 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | B4 | Dec 28, 2020 |
| Nov 23, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE CABINET UNDER SINK IN THE KITCHEN LOCATED AT APT B10... | B10 | Dec 28, 2020 |
| Nov 23, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER INSTALLED AT WINDOW LEADING TO THE ... | B4 | Nov 29, 2020 |
| Nov 23, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... | D2 | Dec 28, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE LOCKED TO RISER PIPE AT PUBLIC HALL, 4th STORY | — | Dec 24, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RISER PIPE AT PUBLIC HALL, 4th STORY | — | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT F5, 6th STORY,... | F5 | Dec 24, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING AT THE FIRE DOOR AT PUBLIC HALL, 4th S... | — | Feb 22, 2021 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE... | F5 | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT F5, 6th STORY,... | F5 | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LEADER TO LEADER BOX AT EXTERIOR OF BULKHEAD AT ROOF , SECTION ''EAST'' | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | F5 | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH OF BOTH WINDOWS IN THE 2nd ... | F5 | Dec 24, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE RADIATOR IN THE 1st ROOM FROM EAST AT NORTH LO... | F5 | Feb 22, 2021 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING AT THE FIRE DOOR AT PUBLIC HALL, 2nd S... | — | Feb 22, 2021 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 1ST RUNG UP FROM BOTT... | — | Nov 25, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ROTTED STEEL LINTELS ABOVE EXTERIOR WINDOWS; 7, 8, 9, 22,... | — | Dec 24, 2020 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD 4TH UP FROM BOTTOM AT PUBLIC HALL, 1st STORY... | — | Nov 25, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ROTTED STEEL LINTELS ABOVE EXTERIOR WINDOWS; 5, 6, 7, 8, ... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS UNDER STAIRWAY AT PUBLIC HALL, 1st STO... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE METAL HANDRAIL AT STAIRS AT 1ST LANDING AT PUBLIC HALL, 1st STORY, SECTI... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 5th... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETATRDANT MATERIAL AT CEILING ... | — | Dec 24, 2020 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE TO SLOP SINK... | — | Dec 15, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, ... | — | Feb 22, 2021 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE TO ROOF AT B... | — | Dec 15, 2020 |
| Nov 19, 2020 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT SLOP SINK... | — | Dec 15, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION BOTH RISER PIPES AT PUBLIC HALL, 5th STORY | — | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT STAIRWAY AT WE... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 6th STORY, SECTION ''WEST'' | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Dec 24, 2020 |
| Nov 19, 2020 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, ... | — | Feb 22, 2021 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT STAIRWAY AT PU... | — | Dec 24, 2020 |
| Nov 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | F5 | Dec 24, 2020 |
| Nov 13, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT ... | C8 | Feb 16, 2021 |
| Nov 13, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILNGS AND ALL... | C8 | Feb 16, 2021 |
| Nov 13, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN T... | C8 | Feb 16, 2021 |
| Nov 13, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 4th... | C8 | Dec 18, 2020 |
| Nov 13, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT TOP OF STEAM RISER IN THE BATHROOM LOCATED AT APT... | C8 | Feb 16, 2021 |
| Nov 4, 2020 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | A5 | Nov 28, 2020 |
| Nov 4, 2020 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | A5 | Nov 28, 2020 |