ECB violations
1512 Atlantic Avenue, Brooklyn • Block 01203 • Lot 0034
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 23, 2025 | 39164644J | RESOLVE | CLASS - 2 | OBSERVED IN THE BASEMENT, THE HOT WATER EXHAUST VENT IS CRACKED, AND PVC PIPING IS BEING USED ON WASTE LINE WHICH IS ... | $625 | $0 | Jan 7, 2026 |
| Dec 12, 2024 | 39132771X | RESOLVE | CLASS - 2 | OBSERVED 3 PAINTED SPRINKLER HEADS ON THE FIRST FLOOR. AS PER 102.3 OF THE PLUMBING CODE MAINTENANCE. INSTALLATIONS, ... | $0 | $0 | Feb 19, 2025 |
| Nov 1, 2023 | 39098555P | RESOLVE | CLASS - 2 | ILLEGAL PLASTIC ACCESS PANALS INSTALLED ON CEILINGS THROUGHOUT THE BUILDINGS., PROVIDE/MAINTAIN FIRE STOPPING | $625 | $0 | Jan 10, 2024 |
| Oct 31, 2023 | 39098405J | RESOLVE | CLASS - 2 | IN CAR COMMUNICATION INOPERATIVE, REPAIR. BRAKE MAINTENANCE TAG MISSING, PERFORM ROUTINE MAINTENANCE AND PROVIDE AN U... | $625 | $0 | Jan 10, 2024 |
| Feb 27, 2023 | 39080384Y | RESOLVE | CLASS - 2 | OBSERVED IN THE BOILER ROOM IN THE BASEMENT/CELLAR ACTIVE WATER LEAK ON BASE ON THE WATER HEATER. AS PER PC 102.3 MAI... | $625 | $0 | Jun 7, 2023 |
| Nov 1, 2021 | 39050335K | RESOLVE | CLASS - 2 | IMPROPER FUSING ON THE CONTROLLER REPLACE. UPDATE BRAKE MAINTENANCE TAG. | $0 | $0 | Mar 9, 2022 |
| Sep 22, 2021 | 35592064Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.I OBSERVED IN THE BOILER ROOM LOCATED IN THE BASEMENT 2 GAS LEA... | $1,250 | $0 | Feb 2, 2022 |
| Jan 4, 2021 | 39034256M | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $0 | $0 | May 12, 2021 |
| Feb 12, 2020 | 39017467H | RESOLVE | CLASS - 2 | FAILURE TO PROPERLY FIRE STOP FULL CELLAR AREA INCLUDING THE BOILER ROOM, FIRE BLOCK FOAM WAS USED THAT DOES NOT PROV... | $3,125 | -$3,125 | Jul 31, 2020 |
| May 17, 2018 | 37009898R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/COMM'S ORDER CONTAINED IN SUMMONS/VIO#35286702Z ISSUED ON 07/19/2017,& TO FILE A CERT OF CORRECTI... | $1,250 | $0 | Aug 6, 2018 |
| Mar 2, 2018 | 35312925M | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. RECORDS INDICATE NO APPLICATION FILED TO CERTIFY C... | $800 | $0 | Aug 13, 2018 |
| Feb 20, 2018 | 35317551J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. ILLUMINATION FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER BC 1... | $500 | $0 | Jul 25, 2018 |
| Feb 20, 2018 | 35317552L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345. NOTED: OBSERVED AT BASEMENT ... | $500 | $0 | Nov 19, 2018 |
| Dec 28, 2017 | 35297746Y | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O PERMIT. OBSERVED ON ALL FLOORS EXISTING LIGHT FIX TURES REMOVED IN HALL AND REPLACED WITH FLOURES... | $800 | $0 | Jun 11, 2018 |
| Dec 28, 2017 | 35298010X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERVED ON 12/28/ 2017 AT ABOVE ADDRESS SPRINKLER HEADS THROUGHOU... | $500 | $0 | May 16, 2018 |
| Dec 28, 2017 | 35297747X | RESOLVE | CLASS - 1 | UNAPPROVED/UNAFE/UNSUIABLE ELECTRICAL EQUIPMENT, MATERIAL APPARATUS, DEVICE, APPLIANCE OR WIRING IN USE; OBSERVED THR... | $800 | $0 | Jun 22, 2018 |
| Dec 28, 2017 | 35297748H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ADEQUATE GROUND TO ELECTRICAL SYSTEMS. OBSERVED IN BASEMENT, WATER GROUND CLAMP IN A SEVERE STATE ... | $2,400 | $0 | Jun 22, 2018 |
| Oct 4, 2017 | 38258410H | RESOLVE | CLASS - 1 | 1X10,6J1,11I11,23M7,2D6-1X10)STOP SWITCH AND ALARM BELL INOPERATIVE, REPAIR. 6JI)DOOR GAP ON CAR DOOR STRIKE SIDE. 11... | $1,000 | $0 | Nov 20, 2017 |
| Jul 19, 2017 | 35286702Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED OUTSIDE & IN HALLWAYS; LIGHT FIXTURES IN HALLWAYS(FLOORS ... | $500 | $0 | Oct 16, 2017 |
| Feb 8, 2017 | 35226471X | RESOLVE | CLASS - 1 | GAS PIPING NOT LABELED. OBSERVED ON 2/7/17 IN CELLAR GAS PIPING WAS INSTALLED W/O BEING LABELED. RMDY: COMPLY WITH SU... | $800 | $0 | Mar 27, 2017 |
| Feb 8, 2017 | 35226472H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 2/7/17 IN BOILER ROOM INSTALLATION OF IMPROPER SUPPORT... | $500 | $0 | Mar 27, 2017 |
| Feb 8, 2017 | 35226473J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 2/7/17 `XCESSIVE STORAGE IN GAS METER AREA. PHOTOS TAK... | $500 | $0 | Mar 27, 2017 |
| Oct 30, 2015 | 35161329K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALL(S)OR APPURTENANCES.NOTED:VERTICAL CRACKSIN STUCCO FACADE @ VARIOUS LOCATIONS & ELEVATIO... | $250 | $0 | Dec 14, 2015 |
| Apr 14, 2015 | 35057230K | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN NOTICE OF VIOLATION #35108005L ISSUED ON 8/19/14. WORK W/O ... | $0 | $0 | Nov 30, 2015 |
| Mar 9, 2015 | 35061415Z | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV#35108007P ISSUED ON 819/14. ILLEGAL TWO PC BATHROOM AT CELL... | $0 | $0 | Apr 27, 2015 |
| Mar 9, 2015 | 35120533R | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY CO #301534524 PRIOR ECB 35108011H TRANSIENT HOTEL ROOMS OCCUPIED AS PERMANENT H... | $1,200 | $0 | Jun 30, 2015 |
| Mar 9, 2015 | 35120531N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE REQUIRED TWO HOUR FIRE RESISTANT RATING AT STAIRCASE ENCLOSURE AND DIVIDING WALL WITHIN OCCUPANCY ... | $1,600 | $0 | Jun 24, 2015 |
| Mar 9, 2015 | 35120532P | RESOLVE | CLASS - 2 | ILLEGAL USE IN COMMERCIAL DISTRICT C8-2. USE GROUP 5 TRANSIENT HOTEL ROOMS CONVERTED INTO PERMANENT HOUSING CLASS'A'A... | $800 | $0 | Jun 30, 2015 |
| Feb 26, 2015 | 35042983N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE C OF C W/THE DOB'S FOR NOTICE OF VIO #35108006N ISSUED ON 8/19/14 PURSUA... | $800 | $0 | Aug 3, 2015 |
| Feb 26, 2015 | 35042984P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE C OF C W/THE DOB'S FOR NOTICE OF VIO #35108010X ISSUED ON 8/19/14 PURSUA... | $0 | $0 | May 20, 2015 |
| Feb 26, 2015 | 35061308N | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV #35108005L ISSUED ON 8/19/14.WORK W/O A PERMIT.INSTALLED ST... | $0 | $0 | May 20, 2015 |
| Aug 19, 2014 | 35108008R | RESOLVE | CLASS - 1 | SEC. 1021.2;27-375(I)1(G) FAILURE TO PROVIDE THE REQUIRED 2HRS FIRE-RESISTANT RATING AT STAIRCASE ENCLOSER & DIVIDING... | $0 | $0 | Mar 27, 2015 |
| Aug 19, 2014 | 35108011H | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY # 301534524, NOTED TRANSIENT HOTEL ROOMS CONVERTED... | $0 | $0 | Mar 25, 2015 |
| Aug 19, 2014 | 35108006N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG. NOTED STRUCTURAL STEEL THROUGHOUT CELLAR NOT FIRE PROOFED. REMEDY: PROVIDE FIRE PROOFING. | $1,000 | $0 | Mar 27, 2015 |
| Aug 19, 2014 | 35108005L | RESOLVE | CLASS - 1 | WORK W/O PERMIT,ILLEGAL WORK NOTED AT CELLAR W/THE INSTALLATION OF STEEL BEAM REINFORCEMENT THROUGHOUT. SHORING IN PL... | $0 | $0 | Mar 27, 2015 |
| Aug 19, 2014 | 35108007P | RESOLVE | CLASS - 2 | WORK W/O PERMIT, ILLEGAL WORK NOTED AT CELLAR LEVEL WITH THE ERECTION OF 2 BATHROOMS SINK & TOILET, NO PERMITS ON FIL... | $0 | $0 | Mar 27, 2015 |
| Aug 19, 2014 | 35108009Z | RESOLVE | CLASS - 2 | ILLEGAL USE IN A COMMERICAL DISTRICTS(C8-2)NOTED APT HOTEL CLASS "A" APTS W/PERMANENT HOUSING,CONVERTED FROM TRANSIEN... | $0 | $0 | Mar 25, 2015 |
| Aug 19, 2014 | 35108010X | RESOLVE | CLASS - 1 | SEC. 27-363(6)(2) FAILURE TO PROVIDE TO REQUIRED TRAVEL DISTANCE REQUIRED IN A J-1 OCCUPANCY GROUP,FOR EXITS SERVING ... | $0 | $0 | Mar 27, 2015 |
| Aug 19, 2014 | 35066856R | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. DURING PHYSICAL INSPECTION I OBSERVED 1 LAVATORY,2 TOILETS & RELATED WASTE,HOT/COLD WATER LINES IN... | $1,600 | $0 | Mar 25, 2015 |
| Feb 8, 2005 | 34463693Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING.DEFECT NOTED:LEADER PIPE APPROX 30'LONG MISSING FROM CONNECTIONS TO THE ROOF DRAIN,WHICH... | $0 | $0 | Mar 28, 2005 |
| Jul 23, 2004 | 34444392R | RESOLVE | Non-Hazardous | WORK W/O A PERMIT. EXPIRED PERMIT. NOTE : PERMIT # 301534524 OBTAIN TOCONVERT EXISTING FACTORY TO TRANSIENT HOTAL ROO... | $500 | $0 | Mar 14, 2005 |
| Jul 23, 2004 | 34444393Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE APPROVED PLANS AT PREMISES AT TIME OF INSPECTION NOTE: INTERIOR RENOVATION AND CONSTRUCTION WORK I... | $130 | $0 | Mar 14, 2005 |
| Jan 23, 2004 | 34414113H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECTS ARE WATER PENETRATING AROUND CORRIDOR WINDOWS LOCATION WEST SIDE BETWEEN CAFETERIA AND GY... | $0 | $0 | Mar 29, 2004 |
| Sep 24, 2003 | 34413285J | RESOLVE | Non-Hazardous | NO PERMIT FOR FENCE NOTE PARTIAL CONSTRUCTION FENCE CONSTRUCTED ON KINGSTON AVE SIDE OF BLDG BEFORE FIRST OBTAINING A... | $0 | $0 | Nov 10, 2003 |
| Sep 24, 2003 | 34413284H | RESOLVE | Hazardous | WORK W/O A PERMIT.WORK NOTED:GUT REHAB RENOVATION WORK IN PROGRESS THROUGHOUT BLDG.NOTE:APPLICATION #301534524 FILED ... | $0 | $0 | Nov 10, 2003 |
| Sep 23, 2003 | 34413286L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN.DEFECTS IS:AN ACCUMLATION OF CONSTRUCTION DEBRIS LOOSE BRICKS ABD GARBAGE BAGS ALSO PLYWOOD AND L... | $0 | $0 | Nov 10, 2003 |