Maintenance code violations
599 Franklin Avenue, Brooklyn • Block 01205 • Lot 0005
165 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Jul 10, 2017 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN CLOSET IN THE PRIVA... | 1L | Jul 18, 2017 |
| Jul 10, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WAL... | 1L | Aug 14, 2017 |
| Jul 10, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM WE... | 1L | Aug 14, 2017 |
| Jul 10, 2017 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1L, 1st STORY, 1... | 1L | Aug 14, 2017 |
| Jul 10, 2017 | C | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING AND ALL WALLS APPROX.... | 1L | Jul 18, 2017 |
| Jul 10, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ESCUTCHEON PLATE AROUND STEAM RISER AT CEILING AND FLOOR ... | 1L | Aug 14, 2017 |
| Jul 6, 2017 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE PRIVATE HALLWAY... | 1L | Jul 14, 2017 |
| Jul 6, 2017 | A | VIOLATION CLOSED | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... | — | Oct 9, 2017 |
| Jul 6, 2017 | A | VIOLATION CLOSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Oct 9, 2017 |
| Jul 6, 2017 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Oct 9, 2017 |
| Jul 6, 2017 | A | VIOLATION CLOSED | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Oct 9, 2017 |
| Jul 6, 2017 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Oct 9, 2017 |
| Jul 6, 2017 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Oct 9, 2017 |
| Jul 6, 2017 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATE... | 1L | Jul 14, 2017 |
| Mar 1, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM THE BUILDING ENTRANCE TO THE BOX AT T... | 1L | Jun 4, 2017 |
| Mar 1, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT A... | 1L | Apr 5, 2017 |
| Mar 1, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 1L | Apr 5, 2017 |
| Mar 1, 2017 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1L, 1st STORY, 1... | 1L | Apr 5, 2017 |
| Mar 1, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORT... | 1L | Apr 5, 2017 |
| Mar 1, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LEAK AT RADIATOR AIR VALVE CONNECTION IN THE KITCHEN LOCAT... | 1L | Apr 5, 2017 |
| Feb 21, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK WALL AT NORTH IN THE BATHR... | 1L | May 27, 2017 |
| Feb 21, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORT... | 1L | Mar 28, 2017 |
| Feb 21, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL IN THE BATHROOM L... | 1L | May 27, 2017 |
| Feb 21, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL IN THE BATHROOM LO... | 1L | May 27, 2017 |
| Feb 21, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK WALL AT WEST IN THE BATHRO... | 1L | May 27, 2017 |
| Feb 21, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM L... | 1L | May 27, 2017 |
| Feb 21, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCK CEILING IN THE BATHROOM LO... | 1L | May 27, 2017 |
| Feb 21, 2017 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1L | Mar 28, 2017 |
| Feb 14, 2017 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Feb 22, 2017 |
| Feb 14, 2017 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | May 20, 2017 |
| Feb 8, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR AIR VALVE IN THE KITCHEN LOCATED AT APT 1L, 1st S... | 1L | Mar 15, 2017 |
| Feb 8, 2017 | A | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT NORTH WALL IN THE BATHROOM... | 1L | May 14, 2017 |
| Feb 8, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING, NORTH AND EAST WALL... | 1L | May 14, 2017 |
| Feb 8, 2017 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, NORTH AND EAST WAL... | 1L | Mar 15, 2017 |
| Feb 8, 2017 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORT... | 1L | Mar 15, 2017 |
| Nov 28, 2016 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Mar 3, 2017 |
| Oct 18, 2016 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, ... | 2F | Oct 15, 2016 |
| Oct 17, 2016 | B | VIOLATION DISMISSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES LOW WATER PRESSURE IN THE KITCHEN LOCATED AT... | 2F | Nov 21, 2016 |
| Oct 17, 2016 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM .. AT CELLAR | — | Oct 25, 2016 |
| Oct 17, 2016 | B | VIOLATION DISMISSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2F | Nov 21, 2016 |
| Aug 15, 2016 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EA... | 3F | Sep 19, 2016 |
| Aug 15, 2016 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Nov 18, 2016 |
| Aug 15, 2016 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE BELL/BUZZER/INTERCOM SYSTEM FROM STREET ENTRAN... | 3F | Nov 18, 2016 |
| Jun 27, 2016 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING , 2 WOOD BALUSTERS AT RAILING AT PUBLIC HALL, 2nd STORY | — | Jul 5, 2016 |
| Jun 27, 2016 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE P... | 4L | Aug 1, 2016 |
| Jun 27, 2016 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 4L | Aug 1, 2016 |
| Jun 27, 2016 | C | VIOLATION CLOSED | SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRICAL ... | 4L | Jul 5, 2016 |
| Jun 27, 2016 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF , EXPOSED ELECTRI... | 4L | Jul 5, 2016 |
| Jun 27, 2016 | C | VIOLATION CLOSED | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE , 2 WOOD BALUSTERS AT PUBLIC HALL STAIRS, 3rd STORY | — | Jul 5, 2016 |
| Mar 28, 2016 | B | VIOLATION CLOSED | § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP... | — | May 2, 2016 |