1393-1395 Dean Street, Brooklyn
Brooklyn • Block 01209 • Lot 0055 • Zip: 11216
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 5 days ago- Downtown Brooklyn 27 min 7 walking, 20 riding
- Fulton Street 32 min 7 walking, 25 riding
- Union Square 41 min 7 walking, 34 riding
- Penn Station 42 min 7 walking, 35 riding
- Times Square 43 min 7 walking, 36 riding
- Grand Central 45 min 7 walking, 38 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Dolores
No description yet
Corto
Corto is a cozy cafe nestled in the heart of Brooklyn, offering a warm and welcoming atmosphere. Enjoy artisanal coff...
Daphne's
Daphne's is a cozy neighborhood restaurant in Brooklyn offering a diverse menu of Mediterranean-inspired dishes. Enjo...
A&A Bake Doubles and Roti
No-frills counter-serve outfit serving Caribbean restaurant - Trinidadian snacks such as pholorie, saheena & aloo pie.
Juici Patties
No description yet
David's Brisket House
Simple nook preparing hearty deli sandwiches such as pastrami, brisket & corned beef.
Peaches Hothouse
Peaches Hothouse in Brooklyn offers a unique blend of Southern comfort food with a spicy twist. Known for their famou...
Sol Delish
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation May 4, 2026
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2024
-
HPD violation Nov 26, 2024
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2023
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
2022
-
HPD violation Jan 21, 2022
Class A
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING [DOOR STOPS INSTALLED ON VESTIBULE DOO...
-
HPD violation Jan 21, 2022
Class C
§ 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS AT THE BUILDING FRONT ENTRANCE , 1st STORY
-
HPD violation Jan 21, 2022
Class C
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING MAXIMUM ALLOWED TEMPERATURE OF1...
-
HPD violation Jan 21, 2022
Class A
§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ...
2019
-
CLASS - 2
OBSERVED IN THE BASEMENT THE INSTALLATION OF THE GROUND ELECTRODE CONDUCTOR IMPROPERLY; THE GEC IS INSTALLED MORE THA...
-
CLASS - 2
OBSERVED THE USE OF FLEXIBLE MC RACEWAY OUTDOORS TO SUPPLY POWER TO A SPLIT A.C SYSTEM ON THE LEFT SIDE OF THE BUILDI...
-
CLASS - 2
OBSERVED IN 3RD FLOOR BATHROOM A DEFECTIVE GFCI OUTLET AND IN THE BASEMENT LAUNDRY ROOM NO GFCI PROTECTION WITHIN 6 F...
-
CLASS - 3
FAILURE TO PROVIDE PANEL DIRECTORY ON ALL FLOORS AND IN BASEMENT. PHOTOS TAKEN, PROVIDE CIRCUIT DIRECTORY/ID
-
CLASS - 2
FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35297831Z ISSUED ON 12/29/17 AND TO FILE...
2018
-
CLASS - 2
FAILURE TO MAINTAIN BLG IN CODE-COMPLIANT MANNER:NO FIRE STOPPING PER BC 712.3;27-345 NOTED:@BSMT LEVEL,IN BOILER ROO...
-
DOB violation May 16, 2018
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation May 16, 2018
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Apr 4, 2018
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2003
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records