ECB violations
637-639 St Marks Avenue, Brooklyn • Block 01219 • Lot 0069
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 6, 2026 | 39187433L | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR SU... | $1,280 | $1,280 | Jul 15, 2026 |
| Nov 10, 2025 | 39166418K | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN VIOLATION 039102744N 1-4-24;CORRECT VIOLATION+SUBMIT CERT... | $6,250 | $6,250 | Jan 21, 2026 |
| Apr 23, 2025 | 39539457M | ACTIVE | CLASS - 2 | OBSERVED SIDEWALK SHED IN PLACE BUT NOT INSTALLED IN ACCORDANCE WITH CODE. MULTIPLE EXPOSED BOLTS WITHOUT PROTECTIVE ... | $10,000 | $10,000 | Oct 27, 2026 |
| Sep 13, 2024 | 39124857R | ACTIVE | CLASS - 2 | ATOI, OBSERVED AT EXPO 1, UNSAFE/UNSUITABLE ELECTRICAL WIRING AT UNDERSIDE OF METAL SIDEWALK SHED WITH LOOSE STRAPS, ... | $800 | $800 | Apr 21, 2025 |
| Aug 8, 2024 | 39121260K | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED OWNERSHIP FAILED TO COMPLY WITH COMISSIONERS ORDER BASED ON DOB VIOLATION 24-01161 ISS... | $0 | $0 | Mar 27, 2025 |
| Jul 11, 2024 | 39530475P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED PEDESTRIAN PROTECTION SIDEWALK SHED IN PLACE AT EXPOSURE #1 WITH ACTIVE PERMITS. UPON ... | $5,000 | $5,000 | Dec 15, 2026 |
| Jun 4, 2024 | 39115869J | ACTIVE | CLASS - 3 | HB SMITH 28-6 BOILER=PERMIT 340202925 EXPIRED WITHOUT SIGNOFF+FRESH AIR MISSING LOUVER;CORRECT VIOLATION+SUBMIT CERTI... | $500 | $500 | Aug 14, 2024 |
| May 1, 2024 | 39113172K | ACTIVE | CLASS - 2 | I OBSERVED THROUGH AN OPEN HOLE ON THE STAIR LANDING BETWEEN THE FIRST AND SECOND FLOOR WATER SATURATED AND RUSTED WI... | $800 | $800 | Aug 15, 2025 |
| Apr 24, 2024 | 39112581R | ACTIVE | CLASS - 1 | ATOI, OBSERVED AT EXPO 1, 60+ FOOT ROOF SOFFIT CRACKED WITH HOLES. OBSERVED UNSUPPORTED & LOOSE PARAPET BRICKS AT BOT... | $1,250 | $1,250 | Jan 27, 2025 |
| Jan 4, 2024 | 39102744N | ACTIVE | CLASS - 2 | HB SMITH 28A-6 BOILER=PERMIT NOT SIGNED OFF/SPILL SWITCH DEFECTIVE/CHIMNEY BASE 1/2 FULL/ CHIMNEY BASE CLEANOUT DOOR ... | $3,125 | $3,125 | Mar 13, 2024 |
| Jan 3, 2024 | 39102672N | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION, OBSERVED WORKER REPAIRING AND DISMANTLING/REINSTALLING GAS SYSTEM PIPING AT EXTERIOR EXPO #1. ... | $2,500 | $0 | Mar 13, 2024 |
| Jan 3, 2024 | 39102690R | RESOLVE | CLASS - 1 | UPON ARRIVAL, OBSERVED WORKER AT EXTERIOR EXPO 1 DISMANTLING/REINSTALLING GAS PIPE. VERRAZANO PLMBG SENT UNQUALIFIED ... | $5,000 | $0 | Mar 13, 2024 |
| Apr 26, 2018 | 35336790K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35236722K ISSUED ON 07/31/17 AND TO FIL... | $0 | $0 | Nov 21, 2018 |
| Mar 3, 2018 | 35311762M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35236722K ISSUED ON 7-31-17 & TO FILE A C OF C PURSUANT... | $0 | $0 | Apr 30, 2018 |
| Jan 28, 2018 | 35282132H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35236722K ISSUED ON 07/31/17 & TO FILE A C OF C PURSUAN... | $0 | $0 | Mar 26, 2018 |
| Jul 31, 2017 | 35236721Z | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT AND/OR APPROVED AMENDMETNS.OBSRVED IN APARTMENT #3D CONSTRUCT... | $1,000 | $0 | Feb 5, 2018 |
| Jul 31, 2017 | 35236722K | ACTIVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.DO NOT OBSERVE ANY DEBRIS IN HALLWAYS,CORRIDOR AND STA... | $4,800 | $0 | Nov 1, 2017 |
| Jul 26, 2017 | 35284676P | RESOLVE | CLASS - 2 | ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED AT 10:30AM PANEL OUTLETS SWITCHES AND OUTLETS INSTALLED IN APARTMENT 1C.APP... | $0 | $0 | Oct 4, 2017 |
| Jul 26, 2017 | 35284679K | ACTIVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPLIANCES APPARATUS MATERIALS OR WIRING IN USE.DEFECTIVE E... | $4,000 | $0 | Sep 5, 2017 |
| Jul 26, 2017 | 35284681J | RESOLVE | CLASS - 2 | FAILURE TO PROTECT CONDUCTORS AGAINST OVERCURRENT PER EC.DOUBLE LUGGINGINS SERVICE SWITCH IN THE BASEMENT.REM:PROVIDE... | $1,200 | $0 | Feb 26, 2018 |
| Jul 26, 2017 | 35256114P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED:REAR FIRE ESCAPE DROP LADDER IN DISREPAIR--BROKEN RUN ON DR... | $1,000 | $0 | Feb 5, 2018 |
| Jul 26, 2017 | 35284677R | ACTIVE | CLASS - 2 | FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES CABLE ARMOR.SERVICE GROUND RACEWAY NOT ... | $600 | $0 | Oct 16, 2017 |
| Jul 26, 2017 | 35256113N | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT/CONSTRUCTION.NOTED:AT BASEMENT LEVEL FULL HEIGHTPARTITION AND WALLS HAS BEEN ERECTED THROUGHOUT... | $0 | $0 | Feb 5, 2018 |
| Jul 26, 2017 | 35284678Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE COVER FACE PLATE LAMPHOLDER LUMINAIRE CANOPY FOR ELECTRICAL OUTLET.PANEL COVER AND END LINE BOX CO... | $0 | $0 | Oct 4, 2017 |
| Jul 26, 2017 | 35251388J | RESOLVE | CLASS - 1 | WORK WITHOUT PERMIT.AT TIME OF MY INSPECTION OF THE ABOVE ADDRESS ON THE ABOVE DATE I OBSERVED IN APT 1C AND CELLAR P... | $1,600 | $0 | Dec 4, 2017 |
| Apr 11, 2007 | 32050460P | RESOLVE | Non-Hazardous | 50,50A,B,C.50-EXPOSED WOOD IN BOILER ROOM.50A-INSUFFICIENT FRESH AIR INTO BOILER ROOM.50B-DEBRIS IN BOILER ROOM.50C-W... | $350 | $0 | Aug 20, 2007 |
| Jan 13, 1998 | 34171488K | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG. HAZARDOUS DEFECTS NOTED: PLASTER WALL AT REAR OF BSMT APT IS BULGING, BROKEN, PARTIALLY COL... | $2,500 | $0 | Mar 2, 1998 |