ECB violations
1030-1036 Park Place, Brooklyn • Block 01243 • Lot 0017
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 30, 2026 | 39186676L | ACTIVE | CLASS - 1 | LACK OF AUTOMATIC SPRINKLER WHERE REQUIRED, OBSERVED 4 CLOTHES DRYERS IN THE SAME ROOM WITH NO SPRINKLER COVERAGE. AS... | $2,530 | $2,530 | May 11, 2027 |
| Apr 30, 2026 | 39186678P | ACTIVE | CLASS - 2 | WORK WITHOUT PERMIT, LAUNDRY ROOM CREATED IN CELLAR, 4 GAS DRYER COMPLETE WITH ALL TYPICAL GAS PIPING, WATER AND WAST... | $1,280 | $1,280 | Jul 8, 2026 |
| Apr 30, 2026 | 39186677N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN. I OBSERVED IN BASEMENT, PLASTIC PIPE ALSO REFERRED TO AS PVC WHICH IS PROHIBITED IN BUILDINGS 5 ... | $1,280 | $1,280 | Jul 8, 2026 |
| Jan 9, 2026 | 39173196J | RESOLVE | CLASS - 2 | 1)IN-CAR COMMUNICATION INOPERATIVE. 2)FIRE EXSTINGUISHER EXPIRED. | $0 | $0 | Mar 18, 2026 |
| Jan 5, 2021 | 39034281Y | RESOLVE | CLASS - 2 | RR FLAME SIGHT GLASS DEFECT-PIOLIT GAS VENT LIMITER MISS-OIL PUMP BELT GUARD MISS-OIL ANTI SIPHON MISS-OIL LEAK@BURNE... | $0 | $0 | May 12, 2021 |
| Oct 3, 2020 | 39029775H | RESOLVE | CLASS - 2 | OBSERVED MINOR CRACK LINES ON CEILING, WALLS AT BEDROOMS, KITCHEN, BATHROOM AND LIVING ROOM IN APT # B7, 2ND FLOOR LE... | $0 | $0 | Feb 3, 2021 |
| Mar 11, 2020 | 39019458P | RESOLVE | CLASS - 1 | PROVIDE IN CASE OF FIRE SIGN IN BSMT. UNREADABLE MAIN LINE FUSES. UNREADABLE CONTROLLER FUSES. PROVIDE MACHINE ROOM V... | $312 | $0 | Mar 1, 2021 |
| May 30, 2014 | 32074356L | RESOLVE | CLASS - 2 | 5B,6A,32A,50,50A 50)SPILL SWITCH DEFECTIVE, 50A)REAR FLAME SIGHT GLASS MISSING | $0 | $0 | Jul 14, 2014 |
| Jul 25, 2006 | 38148766L | RESOLVE | Hazardous | 26#6,40W6,36W6,36M11,55F9,66O2,8V1,11M11,3M11-26 CAN NOT EXIT AFTER EXIT IS OPEN 36-LADDER 11-OPEN & CLOSE BUTTONS 3-... | $350 | $0 | Sep 11, 2006 |
| Aug 8, 2005 | 38149145N | RESOLVE | Non-Hazardous | 16#10/83X10. 16-DOOR LOST MOTION DO NOT MAKE CONTACT. 83-RESTORE CAR BACK TO SERVICE SO THAT A FULL INSPECTION CAN BE... | $180 | $0 | Sep 19, 2005 |
| Sep 9, 2003 | 32043127X | RESOLVE | Non-Hazardous | B4A,30A,32A,34A,50A,50B,50C. 50A-SAFETY VALVES NOT PIPED DOWN. 50B)MANUAL SHUT OFF VALVE MISSING FROM OIL SUPPLY PIPE... | $180 | $0 | Mar 22, 2004 |
| Feb 23, 1998 | 38070865J | RESOLVE | Non-Hazardous | 57O,75U,10I-DAMAGED BUTTON ON CAR STATION. | $350 | $0 | Apr 13, 1998 |
| Aug 8, 1991 | 38014553Y | RESOLVE | Non-Hazardous | 38X,46A,47A,57Q,60M,74M,73M,(60)CWT BUFFER (47)CAPACITY PLATE. (73)FIVE YEAR TEST. PROPER TAG AND FILE ELV3 FORM. | $75 | $0 | Nov 18, 1991 |
| Oct 1, 1987 | 34002996J | RESOLVE | Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTIO... | $300 | $0 | Nov 28, 1988 |