Skip to content

Maintenance code violations

1141 Union Street, Brooklyn • Block 01267 • Lot 0010

2,491 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
Oct 15, 2025 A VIOLATION WILL BE REINSPECTED § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE THE GROUT INBETWEEN THE TILES AT THE WEST, NORT... 6A Jan 18, 2026
Oct 15, 2025 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM Oct 21, 2025
Oct 15, 2025 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH W... 6F Nov 19, 2025
Oct 15, 2025 B VIOLATION CLOSED § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... 2C Nov 19, 2025
Oct 15, 2025 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND WINDOW RECESS IN THE 3rd ROOM FROM EAST LO... 6F Nov 19, 2025
Oct 15, 2025 B VIOLATION DISMISSED § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE UNDER THE WASH BASIN IN THE BATHROOM LOCATED A... 6F Nov 19, 2025
Oct 15, 2025 B VIOLATION CLOSED § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING ... 2C Nov 19, 2025
Oct 15, 2025 B VIOLATION DISMISSED § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... 6F Nov 19, 2025
Oct 14, 2025 C VIOLATION CLOSED § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, ... 2C Oct 11, 2025
Oct 6, 2025 A VIOLATION CLOSED § 27-2005 HMC: REFIT THE LOWER SASH AT THE 1ST WINDOW FROM EAST AT SOUTH IN THE 1st ROOM FROM EAST LOCATED AT APT 1E... 1E Jan 9, 2026
Oct 2, 2025 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... Nov 6, 2025
Oct 1, 2025 A VIOLATION DISMISSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THROUGHOUT ALL WALLS AND CEI... 5K Jan 4, 2026
Sep 29, 2025 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... Nov 3, 2025
Sep 17, 2025 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHR... 1E Oct 22, 2025
Sep 17, 2025 B VIOLATION CLOSED § 27-2005 HMC: REFIT CLOSET DOORS AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1E, 1st STORY, 3rd APARTMENT F... 1E Oct 22, 2025
Sep 17, 2025 A VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT WINDOW REC... 1E Dec 21, 2025
Sep 2, 2025 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE PRIVATE HA... 1E Dec 6, 2025
Aug 14, 2025 C VIOLATION CLOSED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... 5D Sep 7, 2025
Aug 14, 2025 C VIOLATION DISMISSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 5D Sep 9, 2025
Aug 14, 2025 C VIOLATION CLOSED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... 5D Sep 7, 2025
Aug 14, 2025 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... 5D Nov 17, 2025
Aug 14, 2025 C VIOLATION CLOSED § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING 8TH TREAD FROM BOTTOM... Aug 20, 2025
Aug 14, 2025 C DEFECT LETTER ISSUED HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th ... 5D Sep 9, 2025
Aug 14, 2025 B VIOLATION CLOSED § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... 5D Sep 18, 2025
Aug 14, 2025 B VIOLATION CLOSED § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING ... 5D Sep 18, 2025
Aug 4, 2025 C VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE P... 1E Aug 10, 2025
Aug 4, 2025 B VIOLATION DISMISSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALL... 1E Sep 8, 2025
Jul 28, 2025 C VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALL... 1E Aug 3, 2025
Jul 28, 2025 C VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE P... 1E Aug 3, 2025
Jul 28, 2025 A VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEIL... 1E Oct 31, 2025
Jul 28, 2025 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... 5K Aug 3, 2025
Jul 28, 2025 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... 5K Sep 1, 2025
Jul 28, 2025 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT C... 5K Sep 1, 2025
Jul 1, 2025 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( AAPROXIMATELY 10 SQFT ) CEI... 2K Aug 5, 2025
Jul 1, 2025 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT LESS THAN 10 SQFT WINDOW FRAM... 2K Aug 5, 2025
Jul 1, 2025 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT ( APPROXIMATELY 10 SQFT ) NOR... 2K Aug 5, 2025
Jun 2, 2025 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE E... 2K Jul 7, 2025
Jun 2, 2025 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT... 2K Jul 7, 2025
May 23, 2025 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, ... 2A May 23, 2025
May 2, 2025 C VIOLATION CLOSED HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th ... 5A May 28, 2025
Apr 17, 2025 B VIOLATION CLOSED § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE RETURN RAIL AT 3RD AND 6TH STORY BALCONY AT THE 1ST STACK F... May 22, 2025
Apr 9, 2025 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM Apr 15, 2025
Apr 7, 2025 C VIOLATION DISMISSED HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th ... 5D May 3, 2025
Apr 7, 2025 C VIOLATION DISMISSED HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STO... 5D May 3, 2025
Apr 3, 2025 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT CELLAR Apr 9, 2025
Apr 3, 2025 B VIOLATION DISMISSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). THAT IS MISSING IN THE ENTIRE APARTMENT L... 6G May 8, 2025
Apr 3, 2025 B VIOLATION DISMISSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... 6G May 8, 2025
Apr 3, 2025 C VIOLATION CLOSED § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, ... 6A Apr 3, 2025
Apr 3, 2025 C VIOLATION CLOSED § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE OF 130 ... 6G Apr 9, 2025
Mar 31, 2025 C VIOLATION CLOSED § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, ... 6A Mar 31, 2025