| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 24, 2021 | 35557482H | RESOLVE | CLASS - 1 | SEC. 3307.2.1 OBSTRUCTION OF STREET OR SIDEWALK. THE REQUIREMENTS OF THE DEPT OF TRANSPORTATION SHALL APPLY W/REGARD ... | $2,500 | $0 | Nov 3, 2021 |
| Jun 27, 2020 | 35491388M | RESOLVE | CLASS - 1 | HOUSEKEEPING NOTE:AT TIME OF MY INSPECTION OF A 8 STORY BLDG AT FIRST STORY STAGE CONSTRUCTION WORK IN PROGRESS I OBS... | $2,500 | $0 | Apr 19, 2021 |
| Jun 27, 2020 | 35491389Y | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE.NOTE:AT TIME OF MY INSPECTION OF A 8 STORY BLDG AT 1... | $0 | $0 | Oct 28, 2020 |
| Nov 18, 2019 | 35464111X | RESOLVE | CLASS - 2 | BC 3303.14.1 PROTECTION OF FOUNDATIONS @TIME OF INSPECTION ON A 15 STYBLDG CURRENLTY @EXCAVATION PHASE OBSERVED ACCUM... | $0 | $0 | Mar 25, 2020 |
| Nov 18, 2019 | 35464112H | RESOLVE | CLASS - 2 | BC 3304.4.4 GUARDRAIL SYSTEM @TIME OF INSPECTION ON A PROPOSED 4 STY BUILDING CURRENTLY @EXCAVATION PHASE OBSERVED IN... | $0 | $0 | Mar 25, 2020 |
| Nov 18, 2019 | 35464110Y | RESOLVE | CLASS - 2 | BC 3303.7.2 FIRE EXTINGUSHIERS @TIME OF INSPECTION ON A PROPOSED 15 STY BUILDING CURRENTLY @EXCAVATION PHASE OBSERVED... | $0 | $0 | Mar 25, 2020 |
| Nov 14, 2019 | 35461687P | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE SITE SAFETY MANAGER. AT TIME OF INSPECTION AT AN ACTIVE JOBSITE,I REQUESTED TO SEE THE SITE SAFE... | $0 | $0 | Dec 10, 2020 |
| Nov 14, 2019 | 35461683H | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. AT TIME OF INSPECTION,I OBSERVED H-... | $0 | $0 | Dec 10, 2020 |
| Nov 14, 2019 | 35461684J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33. AT TIME OF INSPECTION AT AN ACTIVE JOB SITE,I O... | $625 | $0 | Dec 10, 2020 |
| Nov 14, 2019 | 35461685L | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE SAFETY MEASURES AT JOB SITE. AT TIME OF INSPECTION AT AN ACTIVE JOB SITE,I OBSERVED CONSTRUCTION... | $10,000 | $0 | Dec 10, 2020 |
| Nov 14, 2019 | 35461688R | RESOLVE | CLASS - 1 | SEC. 1704.1.2 NO TR1 SPECIAL INSPECTION/INADEQUATE RECORD KEEPING/FIELD LOGS. AT TIME OF INSPECTION AT AN ACTIVE JOB ... | $625 | $0 | Dec 10, 2020 |
| Nov 14, 2019 | 35461689Z | RESOLVE | CLASS - 1 | SEC. 28-110.1 PLANS INADEQUATE-SITE SAFETY PLANS. AT TIME OF INSPECTION AT AN ACTIVE JOBSITE,I OBSERVED THERE WAS NO ... | $1,250 | $0 | Dec 10, 2020 |
| Nov 14, 2019 | 35461695P | RESOLVE | CLASS - 1 | BC 3310.8 DUTIES OF SITE SAFETY MANAGER-FAILED DUTIES. AT TIME OF INSPECTION AT AN ACTIVE JOB SITE,I OBSERVED WORKERS... | $0 | $0 | Dec 10, 2020 |
| Sep 26, 2019 | 35445558Z | RESOLVE | CLASS - 1 | FAILURE TO NOTITFY THE DEPT PRIOR TO COMMENCMENT OF EXCAVATION.NOTED:IN RESPOND TO INCIDENT INSPECTION REVEAL THAT PR... | $0 | $0 | Apr 27, 2020 |
| Sep 26, 2019 | 35445565R | RESOLVE | CLASS - 1 | BC3304.4.3/INADEQUATE GUARDRAIL SYSTEM AT EXCAVATION SITE.AT TIME OF INSPECTION ON AN ACTIVE JOBSITE 1 OBSERVED GUARD... | $2,500 | $0 | Apr 27, 2020 |
| Sep 26, 2019 | 35418881P | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT RESULTED IN A AFATALITY OR INJURT NOTED ONE WORKER WAS USING A R... | $1,250 | $0 | Mar 11, 2020 |
| Sep 26, 2019 | 35445563N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN RECORD OF PRESHIFT SAFETY MEETING FOR EACH WORK BEFORM COMMENCEMENT OF WORK NOTED IN RESPOND TO A... | $5,000 | $0 | Apr 27, 2020 |
| Sep 26, 2019 | 35445559K | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT PRIOE TO THE COMMENCMENT OF EXCAVTIONS IN RESPONSE TO AN INCIDENT INSPECTION REVEALS... | $0 | $0 | Apr 27, 2020 |