Maintenance code violations

979-993 Carroll Street, Brooklyn • Block 01280 • Lot 0058

1,879 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
May 23, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING A... D6 Jun 27, 2016
May 23, 2016 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BA... D6 Jun 27, 2016
May 23, 2016 C VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT ... D6 May 31, 2016
May 23, 2016 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATH... C2 Jun 27, 2016
May 2, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE BUZZER SYSTEM 1ST STY PUBLIC HALL TO 1ST... A2 Jun 6, 2016
May 2, 2016 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE E... Jun 6, 2016
Apr 28, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERODED MORTAR JOINTS TO NORTH ... Jun 2, 2016
Apr 28, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION ALL STACKS ALL STYS ALL SECTIONS AT FIRE ESC... Aug 1, 2016
Apr 28, 2016 B VIOLATION CLOSED SECTION 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING OF NOT LESS THAN 100 WATTS AT REAR YARD, SECTION ''BLDG 993'' Jun 2, 2016
Apr 28, 2016 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF DISCARDED BED FRAMES AND CARDBOARD BOXES AT FIRE... Jun 2, 2016
Apr 28, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT THE... Jun 2, 2016
Apr 28, 2016 B VIOLATION CLOSED SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. ... Jun 2, 2016
Apr 28, 2016 B VIOLATION DISMISSED SECTION 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING OF NOT LESS THAN 100 WATTS AT REAR YARD, SECTION ''BLDG 991 '' Jun 2, 2016
Apr 28, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNKEYED STUCCO TO NORTH EAST A... Jun 2, 2016
Apr 27, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR UNDER RADIATOR IN T... A2 Jul 31, 2016
Apr 25, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW SASH COUNTERBALANCE IN THE KITCHEN LOCA... C10 May 30, 2016
Apr 18, 2016 C VIOLATION DISMISSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... D5 May 16, 2016
Mar 22, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RISER FROM WEST AT NORTH WALL IN THE... D2 Jun 25, 2016
Mar 22, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE ... D2 Jun 25, 2016
Mar 22, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, NORTH WAL... D2 Jun 25, 2016
Mar 14, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FRO... D5 Apr 18, 2016
Mar 14, 2016 B VIOLATION CLOSED SECTION 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE P... D5 Apr 18, 2016
Mar 14, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS ... D5 Apr 18, 2016
Mar 14, 2016 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE E... D5 Apr 18, 2016
Mar 14, 2016 C VIOLATION CLOSED SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPEC... D5 Apr 11, 2016
Mar 14, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE REFIT .. IN THE 3rd ROOM FROM EAST LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT... D5 Jun 17, 2016
Mar 14, 2016 B VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH AND WES... D5 Apr 18, 2016
Mar 9, 2016 C VIOLATION CLOSED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... D2 Apr 6, 2016
Mar 9, 2016 C VIOLATION CLOSED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... D2 Apr 6, 2016
Mar 9, 2016 C VIOLATION CLOSED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... D2 Apr 6, 2016
Mar 8, 2016 B VIOLATION CLOSED SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... A3 Apr 12, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... B6 Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE REFIT SOUTH 1 WINDOW LOWER SASH IN THE 2nd ROOM FROM NORTH LOCATED AT APT B6, 2nd STORY, 1st... B6 Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... B6 Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCA... B6 Jun 11, 2016
Mar 8, 2016 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT B6, 2nd STORY, ... B6 Apr 12, 2016
Mar 8, 2016 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... B6 Apr 12, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION STEAM RISER PIPE IN THE BATHROOM LOCATED AT ... C1O Jun 11, 2016
Mar 8, 2016 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE E... C1O Apr 12, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB IN THE BATHROOM LOCATED AT APT C1O, 3rd ST... C1O Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... C1O Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... D4 Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT D4, 4th STORY, SECTION ''991'', AT NORTH D4 Jun 11, 2016
Mar 8, 2016 B VIOLATION CLOSED SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT D4, 4th STORY, ... D4 Apr 12, 2016
Mar 8, 2016 B VIOLATION CLOSED SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT A3, 1st ... A3 Apr 12, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION STEAM RISER PIPE IN THE BATHROOM LOCATED AT ... B1 Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... B1 Jun 11, 2016
Mar 8, 2016 B VIOLATION CLOSED SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHRO... B1 Apr 12, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN T... A10 Jun 11, 2016
Mar 8, 2016 A VIOLATION CLOSED SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN IN THE BATHROOM LOCATED AT APT A10, 1st ... A10 Jun 11, 2016