Maintenance code violations
1163-1189 Carroll Street, Brooklyn • Block 01283 • Lot 0001
163 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Apr 4, 2019 | A | NOV SENT OUT | § 27-2005 ADM CODE REFIT CLOSET DOOR AT WEST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 9D, 9th STORY, 1s... | 9D | Jul 8, 2019 |
| Apr 2, 2019 | A | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ( ROTTED ) WOOD FLOOR AT BASE CABINETS AT SINK IN THE KITC... | 9D | Jul 6, 2019 |
| Apr 2, 2019 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 9D | May 7, 2019 |
| Apr 2, 2019 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 9D, 9th STOR... | 9D | May 7, 2019 |
| Apr 2, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WOOD FLOOR INSIDE BASE CABINE... | 9D | Jul 6, 2019 |
| Apr 1, 2019 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSETS DOORS OFF TRACKS IN THE 1st ROOM FROM EAST LOCATED... | 9D | May 6, 2019 |
| Apr 1, 2019 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOORS OFF TRACK IN THE 1st ROOM FROM EAST AT SOUTH ... | 9D | May 6, 2019 |
| Apr 1, 2019 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOORS OFF TRACK IN THE 2nd ROOM FROM EAST LOCATED A... | 9D | May 6, 2019 |
| Mar 27, 2019 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT BATHTUB AND WASH BASIN IN THE BATH... | 9D | Apr 4, 2019 |
| Mar 26, 2019 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 9D | Apr 30, 2019 |
| Mar 26, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT PLYWOOD FLOOR INSIDE SINK CAB... | 9D | Jun 29, 2019 |
| Mar 26, 2019 | A | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ROTTED FLOOR INSIDE AT BASE CABINET AT SINK IN THE KITCHEN... | 9D | Jun 29, 2019 |
| Mar 26, 2019 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 1st BATHR... | 9D | Apr 30, 2019 |
| Mar 26, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPROXIMATELY 1 SQU... | 9D | Jun 29, 2019 |
| Mar 26, 2019 | B | NOV SENT OUT | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 9D | Apr 30, 2019 |
| Mar 26, 2019 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 9D, 9th STOR... | 9D | Apr 30, 2019 |
| Mar 5, 2018 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ... | 15K | Apr 9, 2018 |
| Mar 5, 2018 | B | NOV SENT OUT | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 15K | Apr 9, 2018 |
| Mar 5, 2018 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1s... | 15K | Apr 9, 2018 |
| Aug 2, 2017 | B | NOV SENT OUT | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4K, 4th STORY, 1s... | 4K | Sep 6, 2017 |
| Jul 21, 2017 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AND SHEET ROC... | — | Jul 29, 2017 |
| Jul 21, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL AT PUBLIC HALL,... | — | Oct 24, 2017 |
| Jul 21, 2017 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT THE 4 INCH WASTE LINE IN PUBLIC HALL AT PUBLIC HALL, ... | — | Jul 29, 2017 |
| Jul 21, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT... | — | Aug 25, 2017 |
| Jul 21, 2017 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 12t... | — | Aug 25, 2017 |
| Jul 21, 2017 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING APPRX 2 SQUARE FEE... | 12L | Aug 25, 2017 |
| Jul 21, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST... | 12L | Aug 25, 2017 |
| Jul 21, 2017 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 12L | Jul 29, 2017 |
| Jul 17, 2017 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 12L | Aug 21, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS THRUGH OUT IN T... | 12L | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE PRIVATE HA... | 12L | Oct 20, 2017 |
| Jul 17, 2017 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINLY FLOOR TILE THRU OUT IN THE KIT... | 12L | Oct 20, 2017 |
| Jul 17, 2017 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 12L | Aug 21, 2017 |
| May 5, 2017 | B | NOV SENT OUT | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING & EAST WALL ( APPR... | 4L | Jun 9, 2017 |
| May 5, 2017 | B | NOV SENT OUT | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 4L, 4th STOR... | 4L | Jun 9, 2017 |
| May 5, 2017 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING & EAST WALL IN TH... | 4L | Jun 9, 2017 |
| May 5, 2017 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & EAST WALL... | 4L | Jun 9, 2017 |
| Feb 21, 2017 | C | NOV SENT OUT | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 12D | Mar 21, 2017 |
| Apr 1, 2016 | C | NOV SENT OUT | § 27-2005, 2007 HMC: REMOVE THE ILLEGAL DOUBLE CYLINDER KEY OPERATED LOCKING DEVICE AT DOOR IN THE ENTRANCE LOCATED A... | 1228 | Apr 9, 2016 |
| Mar 7, 2016 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT D UPPER LEVEL, ... | D | Mar 4, 2016 |
| Jan 11, 2016 | B | SECOND NO ACCESS TO RE-INSPECT VIOLATION | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE RADIATOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1167A, ... | 1167A | Feb 15, 2016 |
| Jan 11, 2016 | B | SECOND NO ACCESS TO RE-INSPECT VIOLATION | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE RADIATOR IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 1167A, ... | 1167A | Feb 15, 2016 |
| Aug 17, 2015 | B | SECOND NO ACCESS TO RE-INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SLIDING WINDOW OUT OF TRACK IN THE 1st ROOM FROM NORTH LOC... | 13E | Sep 21, 2015 |
| Aug 12, 2015 | B | VIOLATION CLOSED | § 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE. AT PUBLIC HALL, 1st S... | — | Sep 16, 2015 |
| Mar 25, 2015 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT PUBLIC HALL, 1st STORY | — | Apr 2, 2015 |